GD-7018A Optical Fiber Identifier
GD-7018 usoro ngwa anya eriri pipeline nchọpụta nwere ike n'ụzọ ziri ezi chọta na tụọ omimi nke n'okpuruala pipelines, cables na ngwa anya cables n'okpuru ọnọdụ nke na-enweghị egwu ala, na n'ụzọ ziri ezi na-achọta mmebi isi nke elu mkpuchi nke n'okpuruala pipelines na ọnọdụ nke. n'okpuru ala cable ntụpọ ntụpọ.Ngwa ahụ jikọtara teknụzụ kachasị elu dị ka ihe nzacha eriri ultra-wara warara, nkwurịta okwu ikuku Bluetooth, ọnọdụ GPS, maapụ data akpaka site na sọftụwia nyocha data ọkachamara yana ọgbọ nyocha akpaka.Nchọpụta na nyocha nke ụdị ọkpọkọ ígwè dị iche iche, nhazi na nhazi nke pipeline, nhazi na iwu obodo, nyocha pipeline na ọkụ eletrik na ngalaba ndị ọzọ bụ otu n'ime ngwá ọrụ dị mkpa maka ụlọ ọrụ na-edozi pipeline.
(1) Ọtụtụ ọrụ
1. Ọrụ nnyefe: Ọ nwere ụdị ngwa mgbaama atọ nke usoro ntinye, ụzọ kpọmkwem na usoro mwekota, dabara maka oge dị iche iche.
2. Ọrụ nnata: A na-eji tụọ ọnọdụ, ntụziaka, omimi olili na ugbu a na ọkpọkọ na eriri ala.
3. Aka ekpe na aka nri na-egosi ebe a na-atụ anya pipeline, na ebe a na-edebe ngwa ngwa na nke ziri ezi;ihu na azụ azụ na uru dB na-egosi ebe na nha nke ebe mmebi nke oyi akwa anticorrosive.
4. Na ọrụ backlight, kwesịrị ekwesị maka nnapụta mberede n'abalị.
5. GPS ọnọdụ n'ọnọdu ọrụ, akpaka pipeline map.
6. Ọkachamara data nyocha software, akpaka ọgbọ nke ule akụkọ.
7. Ọrụ pụrụ iche nke onye na-anata 7018E: A na-eji ya achọpụta ihe ndị na-adịghị mma (ọgwụ pipeline na-ezo aka na mmebi nke oyi akwa mgbochi corrosion nke dị n'èzí, ọdịda eriri USB na-ezo aka na mmebi nke oyi akwa mkpuchi), na ịchọpụta mmebi mkpuchi. nke n'okpuru ala pipeline.
8. Ntụle ugbu a: tụọ ugbu a na-etinye site na nnyefe na pipeline n'okpuru ule.
9. Multimeter ọrụ: ọ nwere ike tụọ mmepụta voltaji, akara voltaji, akara ugbu a, impedance na ike.Nwalee ọga n'ihu na mma mkpuchi nke eriri tupu na mgbe achọghị mperi eriri USB.
10. Mwepu ntinye nke mpụga: adabara ebe enweghị ike ijikọ mgbaàmà ozugbo mgbe ị na-achọpụta eriri.
(2) Izi ezi n'ọkwa dị elu
1. Ụdị nha dịgasị iche iche maka ntinye pipeline (ụdị ndagwurugwu, ọnọdụ kachasị elu, ọnọdụ kachasị elu, ọnọdụ akụ kachasị elu) nwere ike ịkwado ọnụ ya iji hụ na nhazi nke pipeline ziri ezi.
2. Usoro kachasị: ọnọdụ kachasị elu, ọnọdụ elu obosara, ọnọdụ akụ kachasị elu nwere ike iji tụọ mgbanwe nke akụkụ kehoraizin ((HX)) ma ọ bụ gradient (△HX), ma chọta dị ka ọnọdụ nke uru kachasị elu;
3. Usoro kacha nta: Jiri ọnọdụ ala iji chọpụta ọnọdụ nke uru kacha nta site na ịlele mgbanwe nke akụkụ kwụ ọtọ (HZ).
(3) Enwere ọtụtụ ụzọ ụda olu
1. Enwere ike ịhọrọ ụzọ nchọta dị iche iche n'ụzọ aka ike ma nwee ike ịnwapụta n'otu n'otu.
2. Direct ịgụ usoro na sọrọ kehoraizin coils.
3. Single larịị eriri igwe 80% usoro, 50% usoro.
4. 45 usoro ogo.
(4) Mgbochi nnyonye anya siri ike
1. Ọtụtụ ihe nleba anya: ma akụkụ kwụ ọtọ (HX), akụkụ kwụ ọtọ (HZ) na gradient (△HX) nwere ike tụọ.
2. Ike nnyefe dị elu: Ike mmepụta nke onye na-ebufe ihe ruru 10W ma na-agbanwe agbanwe.Enwere ike họrọ ya na aka aka dị ka mkpa si dị.
3. Ọtụtụ ugboro na-arụ ọrụ:
Ugboro mbufe: 128Hz, 512Hz, 1KHz, 2KHz, 8KHz, 33KHz, 65KHz, 83KHz.
Ugboro nnata: redio, 50Hz, 100Hz, 512Hz, 1KHz, 2KHz, 8KHz, 33KHz, 65KHz, 83KHz.
4. Dị ka njirimara nke pipeline lekwasịrị anya (ihe, ihe owuwu, omimi e liri, ogologo, wdg), họrọ oge ọrụ kwesịrị ekwesị.
(5) Ọrụ dị mfe
1. kensinammuo: A na-eji ihe ngosi eserese na-egosi na-aga n'ihu na oge dị iche iche na ike mgbaàmà n'oge usoro nchọpụta.
2. Akpaaka: Gbanwee na-akpaghị aka gaa na ọnọdụ antenna abụọ-larịị ma na-emezi mmetụta nke nnata na-akpaghị aka mgbe ị na-atụle omimi, iji nweta akara ngosi nha kachasị mma, ma laghachi na-arụ ọrụ ozugbo tupu emechaa.
(6) Ogologo oge na-arụ ọrụ na-aga n'ihu na ọnụ ala eji eme ihe
Onye na-ebugharị ahụ nwere ngwugwu batrị lithium nwere nnukwu ike, nke nwere ike gboo mkpa ọkụ nke otu ụbọchị maka nchọpụta ubi site na otu ụgwọ, ma nwee ike ịmegharị ya, nke na-ebelata ọnụ ahịa nchọpụta nke ukwuu.
(7) Onye na-ebugharị --AC na DC eji eme ihe abụọ
N'okpuru ọnọdụ nkịtị, ọ bụrụ na batrị nnyefe ejula, jiri ngwugwu batrị arụnyere n'ime ya nye ike.Ọ bụrụ na n'oge eji, batrị na-ebufe dị ala, mana arụghị ọrụ nchọpụta ahụ, ị nwere ike jikọọ ihe nkwụnye ọkụ raara onwe ya nye ozugbo, enwere ike iji ngwa ahụ mee ihe na-emekarị, na-enweghị ichere ka a chajie ngwa ahụ n'ụzọ zuru ezu tupu eji ya.
Nka nka | Ausoro | Busoro | Cusoro | Dusoro | Eusoro |
Ịchọta ugboro ugboro | 5 | 6 | 7 | 8 | 10 |
Ugboro ugboro | 512,1K,33K,83K | 512,1K,33K,83K | 512,1K,33K, 83K | 512,1K,33K,65K,83K | 512, 1K, 2K, 33K, 65K, 83K |
Ugboro ugboro | 50Hz | 50Hz 100Hz | redio 50Hz 100Hz | redio 50Hz 100Hz | redio 50Hz 100Hz |
Ihe nzacha ike | × | × | √ | √ | √ |
Ugboro mperi mperi | × | × | × | × | 2 |
Ịchọta mmejọ | × | × | × | × | √ |
Batrị lithium ion | √ | √ | √ | √ | √ |
Frame | × | × | × | × | √ |
Ịchọta Omimi(m) | 6 | 6 | 6 | 6 | 6 |
Nchekwa data | × | × | × | √ | √ |