GD3126A (GD3126B) Onye Nnwale Nguzogide Mkpuchi Mkpuchi 5kV/10TΩ (10kV/20TΩ)
GD3126A (GD3126B) Ihe nlere mkpuchi mkpuchi mkpuchi bụ nke a na-ejikarị na-arụzi ngwa eletriki na ọdụ ụgbọ mmiri, ụlọ ọrụ ọkụ, wdg. leakage current (Ix) na absorption capacitance (Cx) nke ụdị ngwa voltaji dị elu, gụnyere switchgear, transformers, reactors, capacitors, motors, generators and cables, wdg.
●Na-anabata njikwa microcomputer, ọrụ menu yana nnukwu ihuenyo ntụpọ LCD nwere arụmọrụ kwụsiri ike.
●Ike mgbochi nnyonye anya siri ike, dabara maka ịtụ na gburugburu nnyonye anya electromagnetic siri ike.
●Nnukwu ikike, nwere ike izute ihe achọrọ nke elu voltaji, nguzogide dị elu, nnukwu ule ibu ikike.
●Site na ihe mkpuchi na-awụ akpata oyi n'ahụ, ihe mkpuchi mmiri na uzuzu, na-emegharị na gburugburu ebe ọrụ siri ike.
●Enyi na enyi onye ọrụ, gosipụta nsonaazụ ziri ezi yana usoro mgbanwe data.
●Ọrụ nchekwa zuru oke, nwee ike iguzogide mmetụta nke sekit dị mkpụmkpụ yana voltaji fọdụrụnụ tụrụ atụ.
●5 voltaji mmepụta nzọụkwụ nke 250 V, 500V, 1.0kV, 2.5kV, 5.0kV.
●6 voltaji mmepụta nzọụkwụ nke 250 V, 500V, 1.0kV, 2.5kV, 5.0kV, 10kV.Igwe ọkụ dị elu nke nzọụkwụ ọ bụla na-agbanwe agbanwe site na efu.
●Enwere ike ịhazigharị voltaji dị elu mgbe niile.
●Ntụnye akpaaka nke R15, R60, R600, ngụkọta akpaka nke nha nnabata, ndeksi polarization.
●Oke nha nha nguzogide bụ 0 ~ 10TΩ (0 ~ 20TΩ), oke ngbanwe akpaka.
●Nleta akpaaka nke ọnọdụ okpomọkụ, iru mmiri na oge nnwale.
●Na-egosiputa oge ule, ndụmọdụ buzz na sekọnd 15 ọ bụla, nkeji 5 na-enweghị ọrụ ga-eme ka ọ kwụsị.
●Na-ewepu voltaji dị elu na-akpaghị aka ka emechara nha, oge mgbapụta agaghị agafe 30 sekọnd.
●Nchekwa nke otu 60 nke nsonaazụ nha, enweghị mgbanwe maka afọ 20.
●Site na interface serial RS232, nwee ike iji kọmputa jikọọ data.
●Site na ngwa nbipute mpụga, nwere ike ibipụta nsonaazụ nha.(nhọrọ)
●A na-egosi voltaji nke ihe nlele ebubo tupu anwale ma nwee ihe ndị dị mkpa.
●Oge nlele atọrọ, kwụsị nha na-akpaghị aka;
●Nwere ike ịchọpụta ntapu Ix dị ugbu a yana ikike nnabata Cx.
Usoro voltaji ule enwetara | GD3126A (5kV) GD3126B (10kV) | ||||||
250V, 500V, 1.0kV, 2.5kV, 5.0kV, 10kV | |||||||
Mmeri voltaji pụta | ±5% | ||||||
Oke mgbochi | Oke oke | 500GΩ~10TΩ | |||||
Obere oke | 0.1MM | ||||||
Klas nke ziri ezi | 5.0 klas | ||||||
Njehie ngosi voltaji dị elu | ± ( 5% • Ux + 1 dijitalụ ) | ||||||
Oke nha na mperi ihichapụ ugbu a | 0.1nA ~ 9.9mA 5% | ||||||
Aoke nha nha na mperi bsorption capacitance Cx | 0.1pF ~ 99ɥF 5% | ||||||
Njehie elele okpomọkụ | ± 0.5 ℃ | ||||||
Njehie ịtụ iru mmiri | ± 2% RH | ||||||
Oge sekit dị mkpụmkpụ | <6mA | ||||||
Voltaji ripple | <3% | ||||||
Oge ule | Ruo nkeji 99 | ||||||
Nguzogide mkpuchi | > 500 MΩ (n'etiti waya ule na akpa) | ||||||
Nagide voltaji | AC10.0kV 50Hz 1min (n'etiti waya ule na ikpe) | ||||||
Ịnye ọkụ | 12V batrị lithium | ||||||
Oge ọrụ batrị ka otu chaja gachara | 30days 10 ugboro DAR & 5times PI ule kwa ụbọchị | ||||||
Ọnọdụ okpomọkụ na iru mmiri na-arụ ọrụ | 0℃ ~ + 40℃ <85% RH | ||||||
Nchekwa okpomọkụ na iru mmiri | -20℃ ~ + 50℃ <90% RH | ||||||
Ịnye ọkụ | 220V AC 50Hz | ||||||
Akụkụ (mm) | 325 (L)*250(W)*130(H) | ||||||
Ibu | 3.7kg | ||||||
Njehie nledo ihe mgbochi | |||||||
Nzọụkwụ voltaji | 250 V | 500 V | 1.0kV | 2,5kV | 5.0kV | 10KV | |
± ( 3%·Rx + 1d) | 1GΩ | 2GΩ | 4GΩ | 10GΩ | 20GΩ | 40GΩ | |
± ( 5%·Rx + 1d) | 10GΩ | 20GΩ | 40GΩ | 0.1TΩ | 0.2TΩ | 0.4TΩ | |
± ( 10%·Rx + 2d) | 100GΩ | 200GΩ | 0.4TΩ | 1TΩ | 2 TΩ | 4TΩ | |
± ( 25%·Rx + 2d) | 500GΩ | 1TΩ | 2TΩ | 5TΩ | 10TΩ | 20TΩ |
Ihe nleba anya mkpuchi mkpuchi | 1 set |
Nwalee eriri njikọ maka ọdụ L (Red) | 1 mgbọrọgwụ (1 iberibe) |
Nwalee eriri njikọ maka ọdụ G (Green) | 1 mgbọrọgwụ (1 iberibe) |
Nwalee eriri njikọ maka E terminal (ojii) | 1 mgbọrọgwụ (1 iberibe) |
3APower nkwụnye (Maka ngwa nbipute na ịchaji ngwá ọrụ) | 1 piece (1 iberibe) |
RS232 Serial nkwurịta okwu | 1 mgbọrọgwụ (1 iberibe) |
onye ọrụ's ndu | 1 iko (1 iberibe) |
Akụkọ nnwale | 1 iko (1 iberibe) |
1. L oghere oghere 2. G ọnụ oghere 3. E ọnụ oghere 4. LCD ihuenyo.
5. Buzzer 6. Okpomọkụ & ihe mmetụta iru mmiri 7. bọtịnụ ESC 8. bọtịnụ elu
9. Contrast knob 10. DOWN button 11. OK button12. High voltaji na-edozi isi