GD3128 Series Mkpuchi Mgbochi Nnwale
GD3128 usoro mkpuchi mkpuchi ihe nleba anya nwere ọrụ nnwale zuru oke nke oke nguzogide mkpuchi mkpuchi dị iche iche yana ikike mgbochi nnyonye anya dị mma, nke enwere ike iji nwalee nguzogide mkpuchi nke nnukwu akụrụngwa ọkụ eletrik dị elu na ahịrị nnyefe na gburugburu inductive siri ike dị ka substation.Ngwa ahụ na-anabata ezigbo ihuenyo mmetụ agba, a na-egosipụta data ule niile na ike batrị n'otu ihuenyo n'otu nlele, yana nchikota ngbanwe na igodo na-eme ka ọrụ ahụ dị mfe.Onye ọrụ achọghị iburu usoro ọrụ n'isi.Pịa "Enyemaka" na ihuenyo ka ịmepụta usoro ọrụ, nke nwere ike iduzi onye ọrụ nke ọma ka ọ rụọ ngwá ọrụ ahụ.Ngwá ọrụ ahụ nwere ọrụ nke ịpụpụ ngwa ngwa, nke nwere ike ịwepụ voltaji nke ihe a nwalere ozugbo na-enweghị mgbapụ ọzọ.Ihe nleba anya voltaji nke ngwá ọrụ nwere ike nyochaa ozugbo voltaji dị ndụ nke ihe a nwalere.Ọ bụrụ na voltaji gafere 36V, a ga-amachibido ule ahụ na-akpaghị aka, nke nwere ike ichekwa ngwa na ndị na-arụ ọrụ nke ọma.
Ngwa ahụ na-anabata nnukwu batrị lithium nwere ike ịchaji.Ngụ oge ule nke ngwa na-edekọ oge ule na-akpaghị aka ma chekwaa nsonaazụ ule na ụbọchị na oge.Ihuenyo mmetụ ahụ nwere ike ịnweta data akụkọ ihe mere eme edere n'ụzọ dị mfe.Igwe USB dịpụrụ adịpụ kpamkpam nwere ike bulite data nnwale ahụ na PC n'enweghị nsogbu.Ngwá ọrụ ahụ nwere ahịrị ule nwere mkpuchi mkpuchi okpukpu abụọ na mkpuchi mkpuchi, yana ogwe ọkụ ọkụ dị elu nwere clip na nko na-agbanwe agbanwe, nke nwere ike ime mgbanwe na ebe ule dị iche iche.Ngwá ọrụ ahụ na-eji usoro shei nwere okpukpu abụọ siri ike, na ọkwa nchebe nke igbe dị n'èzí bụ IP65, nke nwere ike igbochi mwakpo nke mmiri na uzuzu n'oge njem na nchekwa, ma chebe ngwá ọrụ ahụ nke ọma site na nkukota.
Usoro GD3128 nwere oke dị iche iche, mkpebi dị elu, ọrụ dị mma, ịdị ike na ịdịte aka, izi ezi na ntụkwasị obi, arụmọrụ kwụsiri ike, yana ikike mgbochi mgbochi siri ike.Ngwa ahụ nwere ule nguzogide mkpuchi (IR);Nnwale index polarization (PI);ule absorption ratio (DAR);ule ramp (RAMP);ule nzacha (FR, 10S, 20S, 30S, 40S nhọrọ anọ);ule voltaji (V);ule ikike (uF);ule ugbu a (nA) na ọrụ ndị ọzọ.Ngwa ahụ dabara adaba maka nyocha mkpuchi mkpuchi nke ngwa eletriki, eriri nnyefe na akụrụngwa ndị ọzọ buru ibu n'okpuru gburugburu ebe ikike dị ukwuu, nnukwu voltaji na induction siri ike.Ọ bụ ngwá ọrụ a na-ejikarị na nke dị mkpa maka ọkụ eletrik, nkwukọrịta, meteorology, ụlọ kọmputa, ebe mmanụ, ntinye na nhazi nke electromechanical, na ngalaba na-enye ọkụ nke ụlọ ọrụ mmepụta ihe na nke Ngwuputa.
●Oke kacha mkpirisi okirikiri ugbu a bụ 7mA.
●Nnwale nguzogide mkpuchi (IR), nyocha index polarization (PI), ule absorption ratio (DAR).
●Ọnọdụ ule Ramp (RAMP), ọnọdụ ule nzacha (FR), ule ikike (uF)
●Ọrụ nlekota voltaji, nyochaa na-akpaghị aka voltaji chaja nke ihe nwalere.
●Ọrụ ngụ oge nwale, dekọọ oge ule na-akpaghị aka.
●Ọrụ mwepụ na-akpaghị aka, na-akpaghị aka na ngwa ngwa hapụ ụgwọ nke ihe nnwale mgbe ule ahụ gasịrị, na-enweghị sekit mpụpụ mpụga.
●Ọrụ nkwụsị akpaaka.
●Nnukwu ihuenyo mmetụ aka.
●Ọdịdị shei okpukpu abụọ, siri ike ma dịgidere, ọkwa nchekwa IP65.
●Ngwungwu batrị lithium nwere ikike dị elu.
●Ọrụ nchekwa, nwere ike ịchekwa otu 1000 nke data nnwale ozugbo yana ụbọchị na oge ule na oge ule.
●Bulite ọrụ, kwadebere na USB interface, ndekọ data nwere ike bulite na kọmputa maka statistical analysis nke data.
Ụdị ngwaahịa | Ogo voltaji | Oke Nguzogide mkpuchi | Obere sekit ugbu a |
GD3128A | 250V,500V,1kV,2.5kV,5kV | 0.50MΩ ~ 10.0TΩ | ≥7mA |
GD3128B | 250V,500V,1kV,2.5kV,5kV,10kV | 0.50MΩ ~ 20.0TΩ | ≥7mA |
GD3128C | 250V,500V,1kV,2.5kV,5kV, 10kV, 15kV | 0.50MΩ ~ 30.0TΩ | ≥7mA |
Oke nguzogide mkpuchi mkpuchi na nke ziri ezi
Ogo voltaji | Ọnụma Nguzogide Mkpuchi | izi ezi | kwuo |
250V | 0.50MΩ~50.0GΩ | ±5%rdg±3dgt |
|
50.0GΩ~500GΩ | ±20%rdg±3dgt |
| |
500V | 1.00MΩ~100GΩ | ±5%rdg±3dgt |
|
100GΩ~1.00TΩ | ±20%rdg±3dgt |
| |
1000V | 1.00MΩ~200GΩ | ±5%rdg±3dgt |
|
200GΩ~2.00TΩ | ±20%rdg±3dgt |
| |
2500V | 1.00MΩ~500GΩ | ±5%rdg±3dgt |
|
500GΩ~3.00TΩ | ±20%rdg±3dgt |
| |
5000V | 1.00MΩ~1.00TΩ | ±5%rdg±3dgt |
|
1.00TΩ~10.0TΩ | ±20%rdg±3dgt |
| |
10KV | 1.00MΩ~2.00TΩ | ±5%rdg±3dgt |
|
2.00TΩ~20.0TΩ | ±20%rdg±3dgt |
| |
15KV | 1.00MΩ~3.00TΩ | ±5%rdg±3dgt |
|
3.00TΩ~30.0TΩ | ±20%rdg±3dgt |
1 TΩ (Tera ohm)=1000GΩ=1012Ω
1 GΩ (Giga ohm)=1000MΩ=109Ω
1 MΩ (Mega ohm)=1000KΩ=106Ω
Ọrụ | Ntụle mkpuchi mkpuchi (IR);Ntụle index polarization (PI);nha nke absorption (DAR);ọnọdụ ule ramp (RAMP);nyoọrụ(10S, 20S, 30S, 40S);vnha oltage (V);capacitancenha(uF);nha ugbu a(nA) |
Ịnye ọkụ | Batrị lithium nwere ike ịgbanye 6.2Ah |
Ogo voltaji | GD3128A: 250V, 500V, 1kV, 2.5kV, 5kV GD3128B: 250V, 500V, 1kV, 2.5kV, 5kV, 10kV GD3128C: 250V, 500V, 1kV, 2.5kV, 5kV, 10kV, 15kV |
Mmepụta voltaji ziri ezi | (5%~10%) ± 10V |
Oke ule Nguzogide mkpuchi mkpuchi | GD3128: 0.50MΩ~10.0TΩ GD3128B: 0.50MΩ~20.0TΩ GD3128C: 0.50MΩ~30.0TΩ |
Mpụta Short Circuit Ugbu a | ≥7mA |
Nnwale Index Polarization | Ee |
Nnwale oke nnabata | Ee |
Ụdị ule Ramp | Nwalee n'ime usoro nke 10% nke voltaji a na-ebu ụzọ ruo mgbe voltaji etinyere ya. |
Ụdị ule nzacha | 10S, 20S, 30S, 40S anọ nhọrọ. |
Ule voltaji | Oke: AC/DC: 0V~1000V; Nzizi: ± 5%rdg± 3V |
Nnwale ikike | Oke: 10nF~25uF; Nzizi: ±10%rdg±10nF |
Ule dị ugbu a | Oke: 0.01nA~7mA; Nzizi: ±5%rdg±0.5nA |
Nyochaa voltaji | Nyochaa voltaji nketested ihe, na nyochaa ọkwa mwepụta mgbe ule gasịrị, amachibidoro ịnwale mgbe voltaji gafere 36V, chebe ngwa na onye ọrụ. |
Ngụ oge ule | Oge ule ndekọ akpaaka, timingogologo: 0s ~ 9999s |
Ọrụ Nchekwa | Na-echekwa data ule na-akpaghị aka na ụbọchị na oge ule, ngụkọta nke otu 1000 |
Ọrụ bulite | Bulite data echekwara na kọmputa site na eriri USB. |
Ngosipụta ike batrị | Site na ngosipụta ike batrị, mgbe voltaji batrị dị ala ga-echetara yaebubobatrị. |
Mkpuchi akpaaka | Mgbe nkeji 15 gachara mmalite ga-emechi na-akpaghị aka na-enweghị ọrụ ọ bụla. |
Akụkụ | 280mm × 260mm × 160mm |
Ibu | 4900g (gụnyere batrị) |
Nwale waya | Agba uhie uhie uhie ule waya 1pc (ya naa clip alligator na nko), waya ule agba ndụ ndụ 1pc, waya ule agba ojii 1pc |
Ọkwa nchekwa | Mechie ikpe IP65, mepee ikpe IP40 |
Environment na-arụ ọrụ | -20 ℃~50 ℃; 80% rh |
Gburugburu ụlọ ahịa | -25 ℃~65 ℃; 80% rh |
Nguzogide mkpuchi | 50MΩ(1000V) (n'etiti sekit ule na shei) |
Nagide voltaji | AC 3kV50Hz 1 nkeji(n'etiti sekit ule na shei) |
Nchekwa | IEC61010-1, IEC61326-1 |