GDC-9560B Ike Sistemụ Mkpuchi Mmanụ Gas Chromatograph Analyzer
GDC-9560B Gas Chromatograph Analyzer bụ inyocha ọdịnaya gas nke mmanụ mkpuchi site na usoro chromatographic gas.Ọ dị irè iji kpee ikpe ma ọ bụrụ na akụrụngwa na-agba ọsọ nwere mmejọ dị ka oke ọkụ, mwepu ma ọ bụ na ọ bụghị, iji hụ na nchekwa nke grid ọkụ.Ọ dịkwa mkpa ka e jiri ya mee ihe maka ndị na-emepụta gas / mmanụ iji nyochaa ngwá ọrụ ha tupu ha ahapụ ụlọ ọrụ mmepụta ihe.
Teknụzụ nyocha chromatography gas bụ usoro maka nkewa na nyocha nke ngwakọta ọtụtụ akụkụ.Ọ tumadi na-eji ihe dị iche nke esi isi, polarity na adsorption ọnụọgụ nke ọ bụla akụrụngwa na sample na kọlụm, nke mere na components na-kewapụrụ na kọlụm, na kewapụrụ components na-qualitatively na quantitatively nyochaa.
chromatograph gas na-eji gas dị ka akụkụ mkpanaka (gas na-ebu).Mgbe ezigara ihe nlele ahụ na injector na vaporized, onye na-ebu ya na-ebu ya n'ime kọlụm juru eju ma ọ bụ kọlụm capillary n'ihi ebe a na-esi esi mmiri, polarity na adsorption coefficient nke akụkụ ọ bụla na sample.Ihe dị iche bụ na a na-ekewapụ ihe ndị ahụ na kọlụm ahụ, mgbe ahụ, a na-achọpụta ihe nrịbama jikọtara na kọlụm ahụ n'usoro dịka njirimara physicochemical nke ihe ndị ahụ, na n'ikpeazụ, a na-eziga akara ọkụ eletrik na-agbanwe na chromatographic workstation.A na-edekọ ma nyochaa chromatogram gas nke akụkụ ọ bụla site na ebe a na-arụ ọrụ chromatographic iji nweta nsonaazụ nyocha nke akụkụ ọ bụla.
●Ọ na-anabata interface nkwurịta okwu Ethernet adaptive 10/100M dị elu yana nchịkọta protocol IP arụnyere, nke na-enyere ngwá ọrụ ahụ aka ịghọta nnyefe data ogologo oge site na LAN na Ịntanetị.Ọ na-eme ka nhazi nke ụlọ nyocha na-eme ka ụlọ nyocha dị mfe.Nhazi ahụ na-akwado njikwa data nyocha.
●Nhazi nke usoro njikọ njikọ onwe 3.Enwere ike ijikọ ya na nhazi mpaghara (ụlọ nyocha), nke dị mma maka ndị nlekọta iji nyochaa ọnọdụ ọsọ na nyochaa nsonaazụ ya.
●NetChromTM arụ ọrụ nhọrọ nwere ike ịkwado ọtụtụ chromatographs n'otu oge maka nhazi na njikwa data, na-eme ka njikwa akwụkwọ dị mfe yana ibelata ego ụlọ nyocha onye ọrụ na mmefu ọrụ.
●Sistemu na Bekee na Chinese, nke enwere ike ịgbanwere ya n'efu.
●Enwere ike ịkpọ mpaghara njikwa okpomọkụ n'efu site n'aka onye ọrụ, nke dị mma maka ndị ọrụ.
●Iji multiprocessor yiri ọnọdụ arụ ọrụ, kwụsiri ike na ntụkwasị obi.Ọ na-ezute nyocha nlele dị mgbagwoju anya.Ejiri ụdị ihe nchọpụta dị elu dị iche iche dị ka FID, TCD, ECD, na FPD.Enwere ike itinye ihe ruru ule anọ n'otu oge.Ọ dịkwa ike iji usoro mgbakwunye ihe nchọpụta, nke dị mma ịzụta na wụnye ihe nchọpụta ndị ọzọ mgbe azụrụ ngwá ọrụ.
●Ngwa ahụ na-anabata usoro modular, ahaziri ma dochie ya, dị mfe iji kwalite ma chekwaa ịdị irè nke itinye ego.
●Usoro nchịkwa okpomọkụ nke microcomputer ọhụrụ ahụ nwere nhazi njikwa okpomọkụ dị elu na ntụkwasị obi dị elu na arụmọrụ mgbochi.Ọ nwere sistemụ njikwa okpomọkụ nke isii zuru oke, nke nwere ike ịghọta mmemme okpomọkụ nke 16, nke na-eme ka akụrụngwa nwee ike nyocha nlele.Ọ nwere usoro oghere azụ azụ na-akpaghị aka maka oven, nke na-eme ka izi ezi nke njikwa okpomọkụ dị ala ma na-abawanye ọsọ nke ịrị elu / iwetulata.
●Enwere ike ịkwado ngwa ahụ na njikwa eletrọnịkị dị elu (EFC) na onye na-ahụ maka nrụgide eletrọnịkị (EPC) iji ghọta njikwa dijitalụ, nke nwere ike imeziwanye nrụpụta nke nsonaazụ qualitative na ọnụọgụ.
●Mmemme mmalite onwe nke imewe ngwa nwere ike mezue nyocha n'ịntanetị nke nlele gas (chọrọ akụkụ ntụtụ akpaka n'ịntanetị).
●Sistemụ arụmọrụ nke keyboard njikwa microcomputer dum dị mfe ma dịkwa mma iji rụọ ọrụ;na a na-emepụta teknụzụ njirimara akpaka nke onye nchọpụta.Site na nchoputa mmejọ yana nchedo data mgbanyụ ọkụ, enwere ike iburu parampat ndị ahụ ozugbo.
●Ngwá ọrụ ahụ arụnyere obere mkpọtụ, mkpebi dị elu 24-bit AD sekit nwere nchekwa ndabere yana mwepu ntọala.
●Chịkọta akara chromatographic na nhazi data, dabara maka WinXP, Win2000, Windows7 na sistemụ arụmọrụ ndị ọzọ.A na-agụ data a nwalere site na faịlụ CDF na-ezute ụkpụrụ A/A (American Analytical Society), yabụ enwere ike iji ya na ebe ọrụ Agilent, Waters na chromatography ndị ọzọ.
●Sistemu Chromatographic nwere ikike ọgụgụ isi nwere onwe zuru oke, nwere ọkọlọtọ ọkọlọtọ nke MODBUS/TCP, nwere ike iji DCS mechie ngwa ngwa.
●Enwere ike ijikọ ngwá ọrụ ahụ na sampler auto nke ọtụtụ ndị na-emepụta ụlọ na ndị mba ọzọ na-emepụta;dị ka Shimadzu AOC-20i, HTA ụlọ ọrụ HT usoro elu-arụmọrụ mmiri mmiri, gas auto sampler.
Gasị nchọpụta | H2, CO, CO2, CH4, C2H4, C2H6, C2H2.(7 gas),O2(nhọrọ), N2 (nhọrọ) |
Display | 192*64 ntụpọ matrix LCD |
Mpaghara njikwa okpomọkụ | 6 ụzọ |
Oke njikwa okpomọkụ | ụlọ okpomọkụ +5℃~400℃, mmụba 1℃, izi ezi:±0.1℃ |
Usoro mmemme | Nzọụkwụ 16 |
Ọnụego ịrị elu mmemme | 0.1~40℃/min |
njikwa gas | igwe valvụ njikwa mode, eletrọnịkị nrụgide eruba njikwa ọnọdụ nhọrọ |
Ihe omume mpụga | 4 ọwa |
Ụdị injector | kọlụm juru n'ọnụ, capillary, valvụ gas injection ụzọ isii, ntụtụ isi isi akpaka, wdg. |
Ọnụọgụ nke nchọpụta | 4 iberibe;FID, TCD, ECD, FPD (nhọrọ) |
Malite injection | akwụkwọ ntuziaka, akpaka nhọrọ |
Nkwurịta okwu interface | Njikọ Ethernet: IEEE802.3 |
Nkọwapụta onye nchọpụta | |
Ihe nchọpụta ionization hydrogen (FID) | |
Oke nchọpụta | ≤ 2 × 10-11g / s (n-hexadecane / isooctane); |
mkpọtụ ntọala | ≤ 5 × 10-14A |
Ntugharị ntọala | ≤ 1 × 10-13A / 30min |
Ogologo ahịrị | ≥106 |
Ihe nchọpụta nrụpụta okpomọkụ (TCD) | |
Mmetụta | S≥2500mV•ml/mg (benzene/toluene) (na-ebuli elu 1, 2, 4, 8 ugboro nhọrọ) |
mkpọtụ ntọala | ≤20μV |
Ntugharị ntọala | ≤30μV/30 nkeji |
Ogologo ahịrị | ≥104 |
Ihe nchọta ijide eletrọnịkị (ECD) nhọrọ | |
Oke nchọpụta | ≤ 1 × 10-13g / ml (propylene hexa-6 / isooctane) |
mkpọtụ ntọala | ≤0.03mV |
Ntugharị ntọala | ≤0.2mV/30 nkeji |
Ogologo ahịrị | 103 |
Isi iyi redioaktivu | 63 Ni |
Ihe nchọpụta fotometric (FPD) nhọrọ | |
Oke nchọpụta | (S) ≤ 5×10-11g/s, (P) ≤ 1×10-12g/s;methyl parathion/ ethanol zuru oke) |
mkpọtụ ntọala | ≤ 3 × 10-13A |
Ntugharị ntọala | ≤ 2 × 10-12A / 30min |
Ogologo ahịrị | Fma ọ bụ sọlfọ ≥ 102, maka phosphorus ≥ 103 |
Igwe Chromatograph gas | 1 set |
Ihe na-emepụta hydrogen | 1 set |
Igwe ọkụ ọkụ | 1 set |
Multi-arụ ọrụ Shaker | 1 set |
Ọkọlọtọ Nrụgide Mbelata Valve | 1 set |
Nrụgide Nitrogen na-ebelata Valve | 1 set |
Nitrogen cylinder | 1 karama |
Ọkọlọtọ gas | 1 karama |
Ụzọ gas nut M8X1Φ3.2 | 10 pcs |
Nrụgide na-ebelata nkwonkwo valve | 5 pcs |
Mkpụrụ kọlụm capillary Φ0.8 | 4 pcs |
Mkpụrụ kọlụm Φ4.2 na Φ3.2 | Nke ọ bụla 5 pcs |
Igwe anaghị agba nchara gas n'ime ọkpọkọ Φ2 | 10 pcs |
Oghere mkpuchi ụzọ gas | 50 pcs |
Capillary sampler evaporative pad | 50 pcs |
Mpempe akwụkwọ graphite capillary Φ0.8 | 20 pcs |
Mpempe akwụkwọ eserese Φ4.2 na Φ3.2 | Nke ọ bụla 10 pcs |
Fuse | 4 pcs |
M3X5 | 6 pcs |
PE gas ọkpọkọ Φ3 | 20m |
1 ml plastic injector | 5 pcs |
100 ml injector | 5 pcs |
agịga | 10 pcs |
20ml iko injector | 5 pcs |
5ml iko injector | 5 pcs |
1 ml iko injector | 5 pcs |
Mpempe ọnụ ọgụgụ | 2 pcs |
Vaseline 30 g | 2 pcs |
Slotted screwdriver 50mm 70mm | Nke ọ bụla 1 pc |
Crosshead screwdriver 50mm 70mm | Nke ọ bụla 1 pc |
Mkpọchi 8-10 | 1 pc |
Mkpọchi 12-14 | 2 pc |
Mpempe imi dị nkọ | 1 pc |
eriri ala | 1 pc |
Igwe mgbaàmà | 1 pc |
Ụdọ ọkụ | 1 pc |
Okpu rọba | 20 pc |
Aluminom foil akpa | 2 pcs |
agịga ugboro abụọ | 25pcs |
Disk | 1 pc |
Igwe nzikọrịta ozi | 1 pc |
Ihe mgbochi gas | 1 pc |