GDP-311CAW 3-in-1 SF6 Ọdịmma Analyzer
GDP-311PCAW SF6 gas quality analyzer bụ ngwaọrụ enwere ike ime iji tụọ ịdị ọcha gas SF6, ebe igirigi, ihe mejupụtara, ọdịnaya CF4 na ọdịnaya ikuku.Akụkụ bụ isi na ihe mmetụta NDIR nke ụlọ ọrụ ihe mmetụta European mepụtara iji nwalee ịdị ọcha gas SF6, ihe mmetụta RC nke Vaisala, Finland mepụtara iji nwalee ebe igirigi, ihe mmetụta NDIR nke Smartgas mepụtara, Germany iji nwalee ngwaahịa decomposition gas SF6 - CF4.ihe mmetụta ikuku na-anabata teknụzụ itg.E wezụga nke ahụ, anyị na-enwetakwa ibe ngwaike ọkachamara na algọridim ngwanrọ nke STMicroelectronics.
●SF6 nyocha maka sistemụ ike
●Nnwale ịdị mma gas SF6 gas cylinder
●Nnwale dị mma nke gas SF6 maka mgbake na ijikwa ya
●Imepụta gas dị ọcha dị elu
●Semiconductor ụlọ ọrụ ọkọnọ gas kpọrọ nkụ
●Nyocha na mmepe ojiji
●Site na ihe mmetụta dị elu dị elu na ọrụ nhazi nke onwe, nsonaazụ ule na-aka nke ọma n'afọ niile.
●Site na iji ihe eji eme ihe polymer n'oge pipeline gas sitere na Legris, Camozzi na Swagelok, hụ na ọ nweghị ọnọdụ njide mgbidi yana ọsọ nnwale ngwa ngwa.
●A nakweere valvụ na-achịkwa igwe anaghị agba nchara mmanụ iji hụ na nnwale ziri ezi.
●Algọridim ngwanrọ dị elu na-eme ka nnwale ziri ezi nke ihe mmetụta ebubata.
●Na nhazi ikpe na-agbanwe agbanwe.Onye ọrụ nwere ike ikpokọta akụkụ mapụtara n'ụzọ dị mfe.
●Ike na-achọpụta, ọ dịghị mkpa maka oscillation.
●Ntugharị okpomọkụ na mgbazi data nrụgide.
●Teknụzụ mgbakọ na-enweghị isi.
●Sistemụ ọkụ ọkụ lithium dị elu nwere ike ịghọta AC DC ike ọkọnọ okpukpu abụọ.Enweghị mkpa maka ọkụ ọkụ AC na saịtị.Batrị lithium nwere ike na-arụ ọrụ mgbe niile karịa awa 8 naanị.
●Mgbochi nnyonye anya sekit imewe, iji hụ na ntụkwasị obi nke ngwaahịa.
●Enwere ike ịgbatị nkwurịta okwu USB, nkwurịta okwu serial na modul nkwurịta okwu ikuku iji ghọta nkwurịta okwu PC na ọrụ obibi akwụkwọ.(nhọrọ)
●Nchekwa oke, nke nwere ike ịghọta ọrụ nchekwa nke otu 1000 data.
●Ọrụ pretreatment ụzọ gas nwere ike ime ka pipeline ule dị ọcha tupu ọrụ nyocha ubi, nke na-ebelata oge ule.(nhọrọ)
●Site na ọrụ nchedo gburugburu ebe obibi.Ngwa ahụ nwere ọrụ mgbake gas na-anwale, nke nwere ike ịmegharị gas sulfur hexafluoride a tụrụ atụ.(nhọrọ)
●Izizi nha ịdị ọcha bụ 0.5% na oke zuru oke, nke enwere ike itinye iji tụọ mkpokọta SF6 gas na gas 70% SF6.
●Ngosipụta nke ebe nlele ule kacha mma doro anya ma nwee nghọta.Ndị ọrụ nwere ike ịhazigharị ikuku gas ozugbo na ngwa ngwa.
●Ọnụ ụzọ ikuku na-anabata nhazi nke obere nkwonkwo na-ejide onwe ya, ya mere ụzọ ikuku a tụrụ atụ agaghị agbawa mgbe agbajiri ya.