GDPQ-300E Power Quality Analyzer
GDPQ-300E Power Quality Analyzer bụ ngwaọrụ enwere ike ịnwale yana nyochaa ogo ọrụ sistemụ ike.Ọ na-enyocha ma na-anakọta data n'ime ogologo oge na-agba ọsọ, na-enyekwa nyocha kwekọrọ na nyocha ịdị mma ike.Ka ọ dị ugbu a, ọ na-eji ngwanrọ nyocha data, nke enwere ike ibugo data nha na PC.
●ARM na DSP, 16M byte ebe nchekwa.
●Ihuenyo mmetụ, dị mfe ma dabara adaba.
●Enwere ike ibugo data na ịlele na PC.
●Ọdịdị modul, ihe ezi uche dị na ya na ọrụ a pụrụ ịdabere na ya.
●Nkwalite ngwanrọ dị mfe ma dị mma.
●Nyocha zuru ezu nke data nha site na ngwanrọ nyocha data ike dị na PC.
Ọrụ nchọpụta mita
No | Ihe | Nkọwa |
1 | Voltaji/Ugbu a/Ugboro | Ọ nwere ike tụọ atọ-nkeji voltaji, efu ahịrị voltaji, atọ agba ugbu a, efu ahịrị ugbu a, ugboro. Nwere ike igosipụta RMS, ọnụ ahịa kacha elu, oke ebili mmiri/elu, ụdị ifegharị, eserese Trend wdg. |
2 | HAronic ife atụment | Ọ nwere ike tụọ isi ife nke voltaji na ugbu a na2 ~ 50 ugboro harmonicsife.Nsonaazụ nha gụnyere arụmọrụ nkwekọ, ọdịnaya kwekọrọ, ọdịnaya kwekọrọ, yana mkpokọta nkwekọ (THD).Histograms na ọnọdụ eserese, wdg. |
3 | Nleta interharmonic | Ọ nwere ike tụọ 0.1 ~ 19.9 ugboro interharmonics nke voltaji na ugbu a.Nsonaazụ nha gụnyere akụrụngwa interharmonic yana ụkpụrụ dị irè nke mpaghara subset, ọnụego ọdịnaya interharmonic wdg. ọ nwere ike igosipụta histogram, chaatị omume, wdg. |
4 | Ntụle ike | Ọ nwere ike tụọ atọ-usoro waya anọ / atọ-adọ atọ waya ike pụtara ìhè (ike eletrik), ike arụ ọrụ (ike eletrik), ike mmeghachi omume (ike eletrik), ike ihe wdg., ọ nwere ike igosipụtachaatị omume; nwere ike tụọ ọchịchọ of 1, 5, 10, 15, 30 60 nkeji. |
5 | Usoro enweghị nha nha atọ | Ọ nwere iketụọ atọ-phase anọ-waya / atọ-adọ atọ-waya eletriki usoro voltaji na ugbu a mma usoro akụrụngwa, ọjọọ usoro akụrụngwa, efu usoro akụrụngwa, ọjọọ usoro ahaghị nhata ogo, efu usoro ahaghị nhata ogo;akụkụ akụkụ nke atọ voltaji na ugbu a,vector, omume eserese. |
6 | Flicker | Nkeji 1 flicker, nkeji 10 mkpirisi mkpịrịsị, nha flicker ogologo awa 2 |
7 | Voltaji ọzịza / itinye / nkwụsị | Na-achọpụta nandekọ voltaji zara, sags na nkwụsị ihe omume. |
8 | Sagba ume ugbu a | Na-achọpụta na ndekọ ịwa ahụ ihe omume ugbu a |
9 | Harmonic ike | Nwere ike ịchọpụta 2 ~ 30 ugboro ike harmonic, nwere ike igosipụta histogram, omumeeserese, wdg. |
10 | Ike ife | Ctụọ mgbanwe ngwa ngwa nke ike (na-arụ ọrụ, na-arụ ọrụ, ike pụtara ìhè) dị ka oge a kara aka (1 ~ 5 nkeji) |
11 | Ndị na-agafe agafe | Cihe chọpụta voltaji na-agafe agafe karịa 20 microns |
8 | ndekọ nlekota oru | Ọ nwere ike ịdekọ paramita ịdị mma steeti kwụsiri ike ruo ogologo oge, gụnyere voltaji / ugbu a / ugboro ole, harmonics, ike, ahaghị nhata nke atọ, mgbanwe / flicker, na oge ndekọ nwere ike gbanwee site na 3 sekọnd ruo 30 nkeji. |
9 | Digital oscilloscope | Lelee Ụdị ebili mmiri voltaji/ ugbu a |
Ndekọ ziri ezi ọ bụla maka ọrụ nchọpụta
Ihe | tụọ oke | tụọ izi ezi | kwuo |
Voltage/ugbu a / ugboro ugboro | Tvoltaji oge hree: 1000V (uru dị irè) ZVoltaji eriri ero: 70V (uru dị irè) Three oge ugbu a: 6000A (uru dị irè, 1000A ihe mmetụta ugbu a maka nhọrọ) Zeriri eriri ugbu a: 25A (uru dị irè) FNtugharị: 40-70Hz | Voltaji:0.1%rdg±0.05% fs Ugbu a: 0.2%rdg±0.05% fs Frequency: ịgụ±0.01Hz | Here, anyị na-eji A na-adọ voltaji ugboro dị ka atụ ugboro |
Harmonic ebili mmiri | Voltage harmonic: THD+Ebili isi+ 2-50 ugboro harmonic ife. Charmonic nke na-adịghị anya: THD+Ebili isi+ 2-50 ugboro harmonic ife. | Voltage harmonic ife: Uh≥1% UN, ±5% uh; Uh.1% UN, ±0.05% UN Efe harmonic dị ugbu a: Ih≥3% IN, ±5% Ih; Ih.3% IN, ±0.15% n'ime | |
Inter harmonicifetụọ | Voltage harmonic: 0.1 ~ 19.9 ugboroInter harmonicife . CHarmonic ngwa ngwa: 0.1 ~ 19.9 ugboroInter harmonicife | VoltajiInter harmonicife: Uih≥1% UN,5% uh; Uih.1% UN,0.05% UN; Ugbu aInter harmonicife: Ih≥3% IN,5% nke; Ih.3% IN,0.15% n'ime | |
Powee / Ike eletriki | Aike arụ ọrụ: 700kVA Rike arụ ọrụ: 700kVAR Isi ihe ike: 0.00 ~ 1.00 Aike arụ ọrụ: 10000kWh Aike pụtara ìhè: 10000kVAh Rike arụ ọrụ: 10000kVARh Ankezi ike ihe: 0.00-1.00 | Aarụ ọrụ: ịgụ±0.5% Apụtara: ịgụ ihe±0.5% Reactive: ịgụ±0.5% Power ihe: ịgụ±0,005 | |
Three na-adọghị nha nha | FVoltage na-adịghị agwụ agwụ: 1000V (uru dị irè) Fugbu a na-adịghị agwụ agwụ: 6000A (uru dị irè) FUgboro ugboro: 40-70Hz PHase angle: 0-360degree Unha nha: 0.0%-100% | VOle: 0.1%rdg±0.05% fs Cihe mgbawa: 0.2%rdg±0.05% fs Frequency: ịgụ±0.01Hz PHase angle: ịgụ±0.3 ogo Voltage enweghị nguzozi: ịgụ ihe±0.2% Current enweghị nguzozi: ịgụ ihe±0.2% | N'ebe a, anyị na-eji oge voltaji nke A-phase dị ka ngụkọta nha nha |
Voltaji Flicker | 1 nkeji na-egbuke egbuke, obere oge flicker, ogologo oge flicker | Ihe dị ka nkeji 1:±5.5% Nkeji nkeji 10 dị mkpụmkpụ:±5% 2 awa ogologo oge na-egbuke egbuke:≤±5% | |
Voltaji zaa, mikpuo na kwụsị | Nyochaa ma dekọba otu-fase/multi-phase voltaji zara, mbelata voltaji na mgbanyụ nwa oge | Ọkara-efegharị RMS, mmalite oge, oge, njehie oge ọgwụgwụ ± 10ms | Ruo ndekọ mmemme 40 |
Ọganihu Ugbu a | Nyochaa ma dekọọ mmiri mmiri na-agbapụta otu oge/otu oge | Uru rms ọkara ebili mmiri, oge mmalite, ogologo oge, njehie oge ngwụcha ± 10ms | Kwụsị ịtụ mgbe ị na-esere mmemme |
Harmonic ebili mmiri | ngụkọta oge ike harmonic: 1 ~ 30th Harmonic mkpokọta ike nọ n'ọrụ:∑P Harmonic ngụkọta mmeghachi omume ike:∑Q Ngụkọta ike na-arụ ọrụ harmonic dị mma: +∑P Ike arụ ọrụ na-adịghị mma harmonic: -∑P Ngụkọta mmeghari ike harmonic dị mma: +∑Q Ike mmeghachi omume harmonic na-adịghị mma: -∑Q | Ọgụgụ ike harmonic: ± 0.5% | |
Ike ife | Ọ nwere ike ịchọpụta ogologo nkeji 1, 3, 5 nke na-arụ ọrụ, na-emeghachi omume, uru ike ọkara ebili mmiri pụtara, na-edekọ mgbanwe mgbanwe ike. | Ọgụgụ ike ọkara ebili mmiri: ± 0.5% | |
Na-agafe agafe | Mfefe voltaji dabere na ọnụ ahịa ọnụ ahịa karịa 120% | 1.topekempe oge ihe omume enwere ike ịtụnye ihe karịrị 20 microns 2.puru omume ijide ihe omume 98.7% | Enwere ike ịchekwa ihe omume 20 n'otu nha |
Mndekọ ontoring | Record parameters gụnyere voltaji, ugbu a, ugboro, voltaji/ugbu a harmonic ife (mkpokọta harmonic+1-25 ugboro harmonic), three-phase enweghị nguzozi;ike na-arụ ọrụ / na-emeghachi omume / ike pụtara ìhè, ihe ike;mgbanwe/ịtụgharị | Oge nchekwa data: 3s ~ 30min Ogologo oge bụ 3s, na ngụkọta oge nlekota bụ 16h; Ogologo oge a bụ 30min, na ngụkọta oge nlekota bụ 960h. | |
Doscilloscope nke ukwuu | Three frasi voltaji, atọ agba ugbu a, efu akara voltaji na efu akara ugbu a ntabi ife efe | Oke.ugboro nlele: 200kHz Min.ugboro nlele: 100Hz |
●mgbama mgbama voltaji:
Nweta ozugbo, ihe mgbochi ntinye: 1MΩ, 20pF
Ogologo nha: voltaji dị irè uru 1000V
Oriri ike: ihe na-erughị 0.5VA/phase
●Loop ntinye ugbu a:
Nweta ozugbo
Oke nha: uru dị ugbu a 1A, 5A, 10A, 100A, 500A, 1000A, 3000A (họrọ ihe mmetụta ugbu a kwekọrọ)
Oriri ike: Ihe na-erughị 0.5VA/phase
●Tulee ọnụọgụ mgbama: 40Hz-70Hz
●Ngosipụta ihuenyo: 5.7 inch 640 * 480 LCD agba nwere ihuenyo mmetụ
●Nchekwa ebe nchekwa: 128M byte FLASH
●Ọdụ ụgbọ mmiri dị n'èzí: USB (ntinye na diski USB)
●Ọkụ na-arụ ọrụ: batrị Li-batrị a na-ebugharị, oge ọrụ awa 5-6 maka chaja zuru oke
●Ike ọkọnọ: AC100-240V/DC 16.8V-1A ihe nkwụnye ọkụ/ chaja
Onye nyocha | 1 set |
5A mgbachi dị ugbu a | 3 iberibe |
Waya ule voltaji | 1 ibe |
Ihe nkwụnye ọkụ | 1 ibe |
Tụgharịa waya | 1 ibe |
QC gafere | 1 oyiri |
Akwụkwọ ntuziaka onye ọrụ | 1 oyiri |
Akuko ule ụlọ ọrụ | 1 oyiri |
Ndepụta nkwakọ ihe | 1 oyiri |