GDSF-311WPD 3-In-1 SF6 Gas Analyzer
GDSF-311WPD (GDSF-411WPD) bụ ezigbo ngwá ọrụ mgbe ọ dị mkpa iji nwalee mmiri ọdịnaya, ịdị ọcha na decomposition ngwaahịa nke SF6 gas.Akụkụ bụ isi nke ule akara igirigi bụ ihe mmetụta DRYCAP® nke ụlọ ọrụ Finland Vaisala mepụtara.A na-eji ụkpụrụ infrared infrared SF6 gas dị ọcha nke ụlọ ọrụ European Sensor rụpụtara iji nwalee ịdị ọcha nke gas SF6.A na-eji ihe mmetụta electrochemical nke ụlọ ọrụ Mombabo rụpụtara na Switzerland dị ka ihe mmetụta maka nnwale nke ngwaahịa ire ere gas SF6.Site na ibe ngwaike ọkachamara na algọridim sọftụwia dị mma nke STMicroelectronics, anyị ewepụtala ọgbọ ọhụrụ nke nyocha gas 3-in-1.
SF6iru mmiri
●Usoro nha: ụkpụrụ nguzogide na ike
●Oke nha: ebe igirigi -80℃--+20℃(kwado ppmv)
●Nke ziri ezi: ± 1 ℃
(mgbe okpomọkụ ebe igirigi dị n'okpuru 0 ℃, ihe mmetụta mmetụta bụ ebe ntu oyi)
●Oge nzaghachi: 63% [90%]
+20→-20℃ Td 5s[45s]
-20→-60℃ Td 10s[240s]
●Mkpebi: 0.01 ℃
●Mmegharị: ± 0.5 ℃
●Ngosipụta unit: ℃, ppm, ℃P20 (ụkpụrụ gbanwere na 20℃)
●Ngwunye gas: 400-600ml/min
●Ngosipụta ọsọ: 0-1000ml dijitalụ eruba mita
●Ihe nlele gas mgbali: ≤1MPa
SF6Ịdị ọcha
●Usoro nha: Ụkpụrụ nha infrared (usoro sensọ NDIR)
●Oke nha: 0 ~ 100% SF6
●Oge nzaghachi: [90%] 60s
●Nzizi: ± 0.5%FS
●Nkwaghari: ± 0.5%
●Mkpebi: 0.01%
●Ngalaba ngosi:%
SF6Ngwaahịa ire ere
●Usoro nledo: Ụkpụrụ nha nke Electrochemical (Electrochemical series sensọ)
●Oke nha: H2S: 0 ~ 200ppmv
SO2: 0 ~ 200ppmv
CO: 0 ~ 500ppmv
HF: 0 ~ 50ppmv
●Nzizi: H2S: 10ppmv ± 3%
SO2: 10ppmv ± 3%
CO: 50ppmv ± 4%
HF: 10ppmv ± 3%
●Nkwaghari: H2S: 10ppmv ± 2%
SO2: 10ppmv ± 2%
CO: 50ppmv ± 2%
HF: 10ppmv ± 2%
●Mkpebi: 0.01ppmv
●Ngalaba ngosi: ppmv
●Ike ọkọnọ: 220VAC ± 10%, 50Hz, AC / DC ojiji, n'elu-charge nchebe, na-aga n'ihu na-arụ ọrụ bụ ọ dịghị ala karịa 8hours.
●Jiri okpomọkụ gburugburu: -20--+60 ℃
●Iru mmiri gburugburu: 90% RH
●Mmetụta uru nha: Enweghị mmetụta nke nrụgide na mgbaba
●Akụkụ: 395*295*155mm
●Arọ: ihe dịka 2kg.
GDSF-411WPD SF6Ngwaahịa ire ere
●Nzizi: H2S: <10ppmv ±0.3ppmv;> 10ppmv ± 3%
SO2: <10ppmv ±0.3PPmv;> 10ppmv ± 3%
●Nkwaghari: H2S: <10ppmv ±0.2ppmv;> 10ppmv ± 2%
SO2: <10ppmv ±0.2PPmv;> 10ppmv ± 2%
●Ọrụ imegharị ihe na njuputa: imegharị ụlọ 2L,oge imegharị ihe ≤ 5min
Na gas ihicha ọrụ
●Akụkụ: 395*295*315mm
●Arọ: ihe dịka 5kg.
Onye nyocha isi | 1 ibe |
Ihe nkwụnye | 1 setịpụrụ |
Ọkpụkpọ Teflon (gụnyere valvụ mgbanwe na-asọpụta na njikọ ngwa ngwa) | 1 setịpụrụ |
Ọdụdọ ọdụ | 1 setịpụrụ |
Akụkụ mapụtara | 1 setịpụrụ |
chaja | 1 ibe |
Onye ọrụ's Nduzi | 1 ibe |
Akụkọ nnwale | 1 ibe |