GDWR-5A Onye Nleta Nguzogide Ụwa maka Grid Ground
GDWR-5A Earth Resistance Tester bụ ngwa nnwale dị elu nke ejiri rụọ ọrụ n'akụkụ dị iche iche dị ka substations maka ịnwale nguzogide ala na paramita ndị metụtara ya.Ngwá ọrụ ahụ nwere njirimara nke obere olu, ịdị arọ dị arọ, ibu dị mma, ọrụ mgbochi mgbochi siri ike na oke ziri ezi.The ngwá bụ ihe integrated Ọdịdị, wuru na-agbanwe agbanwe ugboro ike ọkọnọ modul, na mmepụta ike ọkọnọ na-anọgide na-agbanwe ugboro mgbanwe.Enwere ike gbanwee ugboro ole ka ọ bụrụ 45Hz ma ọ bụ 55Hz, yana isi ihe nrụpụta dị elu wuru na-eji teknụzụ nzacha dijitalụ dị elu, nke na-ezere nnyonye anya nke ikuku eletrik ugboro ugboro na nnwale ahụ, ma na-edozi nsogbu nke ziri ezi. nha n'okpuru nnyonye anya mpaghara eletrik siri ike.Ọnụ ọgụgụ dị ukwuu nke ule na saịtị na ojiji onye ọrụ na-egosi na mgbe a na-anwale grid grounding n'okpuru ebe ọkụ ọkụ eletrik nke ọdụ ụgbọ mmiri na-agba ọsọ, data a tụrụ atụ nke ihe nleba anya impedance grounding nke netwọk ala pụrụ iche bụ ihe ziri ezi na nke a na-emegharị.Ọ bụ ngwá ọrụ dị mma maka ịlele njirimara njirimara nke nnukwu grids grounding.
●Nnukwu mmetụ LCD zuru oke
Arụ ọrụ ahụ dị mfe, a na-eji ngwá ọrụ nwere ihe ngosi kristal zuru oke na-emetụ aka, nnukwu ọrụ na-arụ ọrụ na-ese onyinyo, usoro ọ bụla doro anya, onye ọrụ ahụ nwere ike iji ya na-enweghị ọzụzụ ọkachamara ọzọ.Enwere ike iji otu mmetụ tụọ usoro a niile, na-eme ka ọ bụrụ ngwaọrụ nha smart smart.
●Teknụzụ mgbanwe ugboro ugboro, nha ziri ezi
Ike mgbochi nnyonye anya siri ike.A na-enye ihe nrụpụta ike nke akụrụngwa site na modul ọkọnọ ike ugboro ugboro n'ime ngwa ahụ, ugboro na-agbanwe na 45Hz ma ọ bụ 55Hz, na-anabata teknụzụ nzacha dijitalụ, na-ezere nrịbama nnyonye anya ugboro dị iche iche na ntụpọ, nke mere na ngwa ahụ. nwere ike nweta oke nkenke, nke ziri ezi na nke a pụrụ ịdabere na ya.
● DSP ngwa ngwa ngwa ngwa
Ezi na ngwa ngwa, ngwá ọrụ na-eji ọkachamara DSP ngwa ngwa mgbaàmà dijitalụ dị ka isi nhazi.N'ịkwado nkwenye ziri ezi nke data nha, arụ ọrụ na ikike nhazi nke ngwá ọrụ n'onwe ya na-akawanye mma.
●Usoro dum nwere ọgụgụ isi nha na njikwa
Site na nkwado siri ike nke isi nhazi nhazi dị elu nke ime, ngwá ọrụ ngwa ngwa na-akpaghị aka na-emecha usoro nhazi mgbagwoju anya dị ka mmepụta ugbu a, nnweta voltaji na ntụgharị ugboro ugboro n'oge usoro nha dum.Ngwa nwere ike na-akpaghị aka na-ekpe ikpe impedance nke ugbu a akaghị, na-akpaghị aka na-akpaghị aka mezie mmepụta nke ugbu a uru nke inter-frequency ọkọnọ ike (pụtara mmepụta ugbu a bụ 5A), na ule ọrụ nwere ike na-akpaghị aka mechaa na-enweghị mmadụ aka.Ọdịnaya nha nke ngwa ahụ gụnyere impedance Z nke grid grounding, ihe nguzogide dị ọcha R yana akụrụngwa inductance dị ọcha X.
●Data nchekwa oke
Ngwa ahụ nwere mgbawa kalenda na ebe nchekwa dị ukwuu.Enwere ike ịchekwa nsonaazụ ule n'usoro oge, yana enwere ike ilele ndekọ akụkọ ihe mere eme n'oge ọ bụla, ma nwee ike wepụta ma bipụta ya.
●Nhazi data nke PC
Enwere ike ibupụ data nke ngwaọrụ ahụ tụrụ site na diski U, wee nwee ike nyochaa ma jikwaa data dị mkpa na PC.
1 | Jiri ọnọdụ | -15ºC-40ºC | RH <80% |
2 | Ụkpụrụ mgbochi nnyonye anya | Usoro ntụgharị ugboro ugboro | |
3 | Ịnye ọkụ | AC 220V±10% (110V±10% nhọrọ) | Generator bụ ekwe. |
4 | Atụ mmepụta ugbu a | 1A-5A nwere ike idozi | |
5 | Atụ mmepụta voltaji | 0V-400V | |
6 | Atụ ugboro nke ike ọkọnọ | 45, 50, 55, 60, 65HZ otu ugboro 45/55, 55/65, 7.5/52.5HZ ugboro abụọ akpaaka | |
7 | Ike mmepụta ewepụtara | 2000W | |
8 | Mkpebi | Mgbochi ala: 0.0001 | |
Akụkụ mgbochi: 0.0001° | |||
9 | izi ezi | Mgbochi ala: ± (1%* ọgụgụ+0.002) | |
Akụkụ mgbochi: ± (1% * ọgụgụ+0.02°) | |||
10 | Oke nha nguzogide | 0.001Ω-5kΩ | |
11 | Akụkụ | 370(L)*295(W)*358(H)mm | |
12 | Ogo ebe nchekwa | Otu 100, na-akwado nchekwa data diski U | |
13 | Ibu nke onye ọbịa | 22 n'arọ |
Mba. | Aha | Ọnụọgụ | Nkeji |
1 | Onye nyocha GDWR-5A | 1 | ibe |
2 | Okpokoro ala (otu ogologo, otu mkpụmkpụ) | 1 | setịpụrụ |
3 | Ahịrị ule ugbu a (acha uhie uhie) | 2 | pcs |
4 | Ahịrị ule voltaji (acha anụnụ anụnụ) | 2 | pcs |
5 | Ụdọ ọkụ | 1 | ibe |
6 | eriri ala | 1 | ibe |
7 | Bipụta akwụkwọ | 1 | mpịakọta |
8 | Fuse | 5 | pcs |
9 | Nyochaa akụkọ | 1 | oyiri |
10 | onye ọrụ' s ntuziaka | 1 | oyiri |