GDYB-S6 Oche Ule Ule Ike Atọ
6-okwa mita ule bench (Three Phase)
●Nhazi kọmpat, mita mita nke akụrụngwa ule na okpokoro okpokoro bụ ihe niile a na-eji aluminum alloy pụrụ iche na tebụl ihu-efere na-eji ihe ọkụ ọkụ na ihe mkpuchi ọkụ.
●Ọ dị mfe iji, ma ahụigodo na ọrụ PC dị.
●Akpaaka dị elu.Naanị onye ọrụ kwesịrị itinye mita na mita, mezie fotoelectric sampler ma tọọ paramita ahụ n'ọnọdụ dị mma, mgbe ahụ, ihe niile nnwale, gụnyere tupu kpo oku, actuation na ụgha actuation ule, ọkọlọtọ deviation ule, isi njehie ule na-achịkwa PC site na otu. nwale.Enwere ike ịkọwapụta usoro nhazi mita.
●Photoelectric sampler nwere ike na-aghọta atọ akụkụ ukpụhọde.Ọ nwere ike ọ bụghị naanị ịlele akara ntugharị efere nke mita rotary kamakwa nata akara strobe nke mita eletrọnịkị.
●Usoro nhazi njehie nwere ike ịnata mgbaàmà site na onye na-ahụ maka fotoelectric na mmepụta mmepụta nke ihe ntinye ụdị eletrọnịkị, na akara mgbama dị elu nke mita ọkọlọtọ.
●Mita n'otu ụdị (otu ahịrị na-adọ, voltaji egosipụtara, ugbu a calibrated) mana enwere ike ịnwale n'otu oge dị iche iche (n'ọtụtụ ụdị 3).
●Nwalee ọrụ nkwurịta okwu RS485 nke mita ọtụtụ arụ ọrụ, njehie achọrọ na njehie clocking bụ nhọrọ (mpụta akara oge dị mkpa).
●Chọta ebe akara nke mita rotary na-akpaghị aka, nke na-eme ka nnwale mmeghari ụgha dị mfe.
●Superimposing 2 ka 21 harmonics na isi ebili mmiri nke ike ugboro, harmonic amplitude na oge nwere ike ịtọ dị ka ihe achọrọ.Ọzọkwa harmonic analysis na sere waveform nwere ike ịrụ maka mmepụta components.
●Nnwale akpaaka na voltaji nkeji ọ bụla, ugbu a, nkwụsi ike ike yana nkwụsi ike ike nke akụkụ atọ.
●Nkwụsi ike dị elu na ntụkwasị obi, nke nwere ike inye ike mmepụta ike.Voltaji (ugbu a) loop nwere ike ibu ụdị ọ bụla.
●A na-enye akụrụngwa nnwale ahụ nleba anya na-adịghị arụ ọrụ zuru oke, ịchọta, nchekwa na ọrụ egwu iji zere imebi oche nke sitere na wiwi akwụkwọ ntuziaka na-ezighi ezi ma ọ bụ arụ ọrụ.
●Akụrụngwa PC na-enye ọrụ zuru oke, dị ka mbipụta akụkọ, ịgụta ọnụ ọgụgụ na idobe akụ
●Ọkwa ziri ezi: 0.05%
●voltaji mmepụta: 3*100V/57.7VY 3*100V ∆
3*380V/220V Y 3*380V ∆
Oke nhazi: 0-120% nwere ike imeghari n'usoro
Ịhazi izi ezi: ka mma karịa 0.01%
* Enwere ike ịhazi oke voltaji pụrụ iche dabere n'usoro n'ezie.
●Oke dị ugbu a: 0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A, 10A, 20A, 50A, 100A
Oke nhazi: 0-120% nwere ike imeghari n'usoro
Ịhazi izi ezi: ka mma karịa 0.01%
●Ike mmepụta: (voltaji loop) GDYB-S6 100VA
(Ugbu a loop) GDYB-S6 150VA
●Nkwụsi ike nke voltaji mmepụta, ugbu a na ike:
≤0.02%/120S PF=1 (Klas 0.05)
≤0.05%/120S PF=1 (Klas 0.1)
●Mgbagha nke voltaji mmepụta na ugbu a: ≤0.5%
●Symmetry nke akụkụ atọ: mma karịa 120°+0.3°
●Oke ugboro: 45Hz-65Hz na-achịkwa izi ezi: 0.01 Hz
●Oke mgbanwe usoro: -180.0°-180.0° na-achịkwa izi ezi: 0.1°
●Ọkọlọtọ kristal oscillator kwụsie ike: ≤10-7/s
●klaasị akụrụngwa na-egosi
Voltmeter na ammeter ziri ezi: ọkwa ± 0.2%
Nkezi mita nke usoro: ± 0.5°
Izizi mita ugboro ugboro: ± 0.01Hz
●Kacha mita maka ule: 6
●Ike ọkọnọ: 3 * 220V± 10%, 50Hz (ma ọ bụ 120V± 10%, 60Hz)
●Oriri ike kachasị: 1500VA
●Ọnọdụ okpomọkụ na-arụ ọrụ: 20± 5℃ iru mmiri: ≤85%
●Akụkụ na ibu:
2000mm * 720 mm * 1550mm 280Kg