GDYM-1A Otu Oge Eletrik Energy Meter Calibrator
GDYM-1A Single-phase Electric Energy Meter Calibrator bụ ngwá ọrụ na-atụ ọtụtụ paramita nke zuru oke dijitalụ, ọtụtụ ọrụ yana nkenke dị elu.Ọ bụghị nanị na-enyere aka calibrating njehie, ma na-atụ voltaji, ugbu a irè uru, arụ ọrụ ike, reactive ike, o doro anya ike, ike ugboro, ike ihe, frasi mmekọrịta, wdg Ọ bụ karịsịa kwesịrị ekwesị maka calibrating nha ziri ezi nke. Igwe ọkụ eletrik nke otu nkeji na ngalaba ọkọnọ ike.
Ọrụ dị mfe na ngwa ngwa, a na-egosipụta usoro ọrụ niile na ihuenyo.
●Ka ịhazigharị mita ike eletrik nke sistemu nha ma tụọ oke voltaji dị ala.
●N'iji teknụzụ isi nke 32 bit 150MHz DPS kachasị ọhụrụ, ihe ntụgharị 16 bit dị elu, njehie ahụ kwụsiri ike na izi ezi dị elu (nke a nwere ọdịiche dị mma na calibrator otu oge nwere mgbawa mita).
●Nnukwu ihuenyo LCD mara mma, na-egosiputa paramita ntọala calibrating, kwekọrọ, paramita eletriki, njehie yana data niile na-atụ n'ike.
●A na-eji njigide dị ugbu a iji mee ka ọ dị ugbu a site na ibu na-emepụta, nke mere ka ọrụ ubi dị mfe ma melite arụmọrụ ọrụ.A ga-egosipụta ugbu a nke ọnụ ọnụ na mwekota yana ike ha na nchikota ike n'otu oge ahụ.
●Iji mwekota 500A na obere mkpọ dị ugbu a iji tụọ oke nke obere voltaji CT.
●Tulee data nkwekọ site na ugboro 2-43, ugbu a na voltaji ga-egosipụta n'ezie ụdị ebili mmiri ọ bụla, nke na-enyere aka ikpebi steeti saịtị.
●Ịgbakọ mita ike mgbe niile n'otu oge ọkụ eletrik.
●Chekwaa data maka mita 1000.
●Jikọọ na PC site RS232 usoro nkwurịta okwu interface.
●Site na mmepụta mkpụrụ akụ dị ala, dị mma maka ịlele onwe na nyocha.
●Ihe calibrator ga-ama ụda site na ụda na ọkụ mgbe ọ na-enye 380V na ahịrị ule voltaji.
●Mgbe ahịrị simulation dị ugbu a na-ezighi ezi jikọtara ya na ahịrị na-anọpụ iche nke mita, nchekwa akpaka mbụ agaghị ewepụta ugbu a.Mgbe ị na-eme njikọ mmejọ ọzọ, fiusi nchekwa nke abụọ ga-ere ọkụ, nke na-emetụta oke nchebe.Ihe calibrator ga-agbake ma dochie fiusi.
●Igwe ọkụ ahụ ga-agbanyụ mgbeAhịrị mkpali ahụ kụrụ 220V, calibrator ga-agbake mgbe ọ dochie fuse.
Oke nha | izi ezi | ||
Voltaji | 10-300V | ± 0.1% | |
Simulation Ugbu a | 5A | ± 20% | |
Mkpọchi dị ugbu a | 100A, 500A | ±0.3%, ±0.5% | |
Terminal dị ugbu a | 0.05-10 A | ± 0.1% | |
Ike | Mkpọchi dị ugbu a | 100A, 500A | ± 0.3%, ± 0.5% |
Ọnụ | 10A | ± 0.1% | |
Akụkụ akụkụ | -180--+180° | ±0.1° | |
Ugboro ugboro | 45-55Hz | ±0.01Hz | |
Ike eletriki | 100A Mgbochi (obere) | 0.25A-110A | ±0.3%, ±0.5% |
500A mgbachi | 25-1000A | ± 0.5% | |
Ngosipụta nso | 100A Mkpọchi ugbu a: 0.01A-110A | ||
Nkwụsị: 0.01A-10A | |||
Igwe ọkụ ọkụ eletrik | FL=1000 imp/kW.h | ||
Voltaji na-arụ ọrụ | AC 100-300 V | ||
Okpomọkụ na-arụ ọrụ | -25 ℃~45 ℃ | ||
Iru mmiri na-arụ ọrụ | <95% Enweghị condensation | ||
Ibu | <1kg | ||
Olu | 215*105*70mm |
GDYM-1A Calibrator | 1 set |
100A mpịachi mita | 1 iberibe |
Ngwanrọ njikwa (CD-ROM) | 1 ibe |
Igwe eletrọnịkị ahịrị usu | 1 ibe |
eriri voltaji | 1 ibe |
Igwe ọkụ | 1 ibe |
232 ahịrị nkwurịta okwu | 1 ibe |
Photoelectric isi | 1 ibe |
0.5A fuse | 1 ibe |
Ngwa ngwa | 1 ibe |
Akwụkwọ ntuziaka | 1 oyiri |