GDYZ-301A Zinc Oxide Surge onye nyocha
Ọ bụ ngwa pụrụ iche nke na-anwale arụmọrụ eletriki zinc oxide.Ngwa ahụ nwere ike tụọ nke ọma na kwụsie ike n'ihe njide resistive ugbu a yana ihe nleba anya counter action parameters ka akụrụngwa na-agba ọsọ.Ọ nwekwara ike ịlele ammeter onye nleba anya.
●8inch agba LCD ihuenyo mmetụ, elu na-agba thermal ngwa nbipute.
●Data nha nke waya na ikuku bụ otu.
●Nlereanya ikuku, nwere ogologo anya.
A. Wired: ojiji ime ụlọ, ma ọ bụ na saịtị ebe kabinet sampling PT dị nso na njide àmụmà nwalere.
B. Ikuku: n'èzí ojiji, ma ọ bụ na-saịtị ebe PT sampling wiring kabinet dị anya na nwalere àmụmà njide, ikuku anya ruru 1000M.
●Enwere ike tụọ akụkụ atọ n'otu oge.The resistive ugbu a nke 3channels nwere ike tụrụ n'otu oge, ka ọ dị ugbu a, e nwere abụọ mgbochi nnyonye anya ụdịdị: 1) ọ dịghị nnyonye anya: interphase angle enweghị ike gbakọọ na-agbazi na-akpaghị aka n'okpuru a mode;2) Site na nnyonye anya: enwere ike gbakọọ ma mezie akụkụ nnyonye anya interphase.Naanị otu oge njikọ iji mechaa nha nke usoro ABC.
●Batrị Li-batrị dị elu arụnyere, dabara adaba maka enweghị mpaghara ọkọnọ ike.
Use ọnọdụ | -20 ℃ - 50 ℃ | RH<80% |
Cike ọkọnọ ike | AC 220V± 10% | |
Ntinye ntinye nke voltaji ntụaka PT | 0-300V | |
Input iguzogide ọwa voltaji | ≥150kΩ(wfuse) | |
Ịtụ izi ezi nke voltaji ntụaka PT | ±(2% nke ọgụgụ+ 0.5V) | |
Mna-eme ka nsonye ntinye dị ugbu a | 0-10mA | |
Measurement ziri ezi nke ugbu a isi | ±(2% nke ọgụgụ+ 5μA) | |
Measurement ziri ezi nke ugbu a harmonic | ±(5% nke ọgụgụ+10μA) | |
Input eguzogide nke ugbu a ọwa | ≤1Ω | |
Action ugboro nke nlekota oru | 0 ~ 99times | |
8/20μS mkpali ugbu a | ≥50Ap | |
Calibration nso nke ugbu a mita | 0-10mA | |
Calibration ziri ezi nke mita dị ugbu a | ±(2% nke ọgụgụ+ 5μA) | |
Mmkpebi nkwenye | Voltage | 0.001V |
Cmmiri iyi | 0.001mA | |
Aakuku | 0.001° | |
Bogologo oge ọrụ | Mnke unit 8hnke anyị, igbe nlele voltaji 12hours | |
Wanya nnyefe ikuku | 1000mita na n'elu (efu nauenweghị mgbochi) | |
Dmmetụta nke isi unit | 320×270×140mm | |
Hnyocha mkpokọta na ejidere | 180×120×80mm | |
Ibu nke isi unit | 4kg (na-enweghị ngwa) |
Motu unit | 1pice |
Sampling unit | 1pice |
Wngalaba nkwurịta okwu ire ere | 1pice |
Measurement cable nke 3-phase resistive ugbu a | 1pice |
Sampling cable nke 3-phase voltaji | 1pice |
Oeriri utput nke mmezi mita dị ugbu a | 1pice |
Geriri gburugburu | 1pice |
Ikeeriri | 1pice |
Charka | 1pice |
Fjiri | 3pcs |
Print akwụkwọ | 1roll |
Ihe nkiri Alligator | 8pcs |
Nyochaa akụkọ | 1 ibe |
Onye ọrụ's ndu | 1 ibe |