GDYZ-302 Wireless Zinc Oxide Surge Arrester Tester
GDYZ-302 Zinc Oxide Arrester Live Tester bụ ngwa pụrụ iche eji anwale arụmọrụ eletriki nke Zinc Oxide Arrester.Ọ dị mma maka nchọpụta ndụ ma ọ bụ nkwụsị ọkụ nke Zinc Oxide Arrester nke ọkwa voltaji dị iche iche, nke mere na ịchọta ntụpọ dị ize ndụ dị ka mmiri mmiri nke mkpuchi n'ime na ịka nká nke efere valve n'oge.
Ngwá ọrụ dị mfe iji rụọ ọrụ ma dị mfe iji.Kọmputa ụlọ ọrụ na-achịkwa usoro nha niile.Ọ nwere ike tụọ ugbu a zuru ezu, resistive ugbu a na harmonics ya, voltaji ntụaka ugboro ugboro na harmonics, ike na-arụ ọrụ na ọdịiche nke oge.Na-egosiputa ezi ụdị ebili mmiri nke voltaji na ugbu a.Ngwa ahụ na-eji teknụzụ nyocha nke waveform dijitalụ yana ụzọ mgbochi nnyonye anya dị ka nyocha nkwekọ na nzacha dijitalụ iji mee ka nsonaazụ nha zie ezi ma kwụsie ike.Ọ nwere ike nyochaa nke ọma ọdịnaya nke isi ebili mmiri na nke atọ ruo nke asaa, ma nwee ike imeri mmetụta nke nnyonye anya n'etiti usoro.Tulee ihe mgbochi nke ihe njide nke akụkụ akụkụ.
●800 * 480 agba LCD ihuenyo mmetụ, ngwa nbipute ọkụ ọkụ dị elu;ndịna-emeputa na ihe ngosi ederede, interface nwere nghọta, dị mfe maka ndị ọrụ ubi iji rụọ ọrụ na iji.
●Ikuku nnyefe nke PT mgbaàmà karịrị 400 mita, nke nwere ike iru 2000 mita na ina.
●Ọ dabara maka onye njide dị ndụ, onye njide ọkụ ma ọ bụ nnwale ụlọ nyocha.
●N'ezie nweta atọ-adọ ugbu a na atọ voltaji nha n'otu oge, melite ọrụ arụmọrụ;Ngwá ọrụ ahụ nwere ugbu a adịghị ike, voltaji anaghị agafe 12V;ihe mmetụta ugbu a na voltaji dịpụrụ adịpụ kpamkpam, nchekwa na ntụkwasị obi.
●Enwere ike tụọ ihe mgbapụta nke zinc oxide na-enweghị counter, nke na-edozi nsogbu nnwale nke 6 ~ 10KV njide.
●Ọ na-akwado ma mmekọrịta wired na ikuku mmekọrịta maka nlele akara ngosi voltaji, ma na-akwadokwa ọnọdụ na-abụghị voltaji maka ịchọta ntụaka voltaji site na ngụkọ ngwanrọ.
●Site na arụmọrụ dị elu yana nnukwu ikike batrị lithium-ion, ọ dabara adaba maka ngwa na-enweghị ike.
●Ngwa ahụ na-anabata usoro ngwaike agbakwunyere na sistemụ arụ ọrụ, nke nwere ike gbasaa ọrụ egwu egwu na vidiyo yana ọrụ ntụrụndụ egwuregwu.
●Enwere ike ịgbanye ma gbanyụọ ngwá ọrụ ahụ n'oge ọ bụla, nke kwụsiri ike karịa ngwá ọrụ dabere na kọmputa mmepụta ihe, ọ dịghịkwa mfe ịdaba na ịdaba.
●Enwere ike ịgbasa ọrụ ngwanrọ n'oge ọ bụla, ebe ọ bụla dịka ihe ndị ahịa chọrọ.
●Ejiri ya na interface USB iji kwado mbupụ data U-disk.Enwere ike iji ya na òké USB na keyboard, ọ dịkwa mfe iji rụọ ọrụ.
●Kaadị SD nwere ikike 4 GB nwere ike ịchekwa nnukwu data nnwale, ma nwee ọrụ nke njikwa data na nchekwa.
●Na-akwado ngwanrọ njikwa PC, yana njikwa data akụkọ ihe mere eme, nyocha data, mbipụta akụkọ na ọrụ ndị ọzọ.
●Ugboro nlele ọsọ ọsọ, teknụzụ nhazi akara dijitalụ dị elu, arụmọrụ mgbochi mgbochi siri ike, nsonaazụ nha dị elu.
●A na-anakwere igbe mkpuchi uzuzu uzuzu, mgbochi mmiri na mgbochi corrosion engineering plastic akara, nke dị obere na nha, dị arọ ma dị mfe iburu.
Ịnye ọkụ | Na-akwado nkwụnye ọkụ mpụga (12V/2A) na batrị dị n'ime |
Oke nha | Mwepu nke ugbu a (uru kacha elu): 0 ~ 10mA (enwere ike ịgbatị) Voltaji (ọnụahịa kacha elu): 30-100V(enwere ike ịgbatị) |
nha nha nha nha | Ugbu a: ± 2% ọgụgụ ± 1 dijitalụ n'uju ugbu a> 100 μA Voltage: ± 5% ịgụ +1 dijitalụ na mgbama voltaji ntụaka <30V: Voltaji: mgbama voltaji ntụaka> 30V: Ụdị waya: + 2% ịgụ +1 dijitalụ; Ọnọdụ ikuku: +5% ọgụgụ +1 dijitalụ; |
Ntụle nha | Ụdị ebili mmiri dị ugbu a zuru oke, RMS bụ isi na uru kacha elu nke ntapu ugbu a; The isi ebili mmiri RMS nke leakage ugbu a resistive akụrụngwa na RMS nke 3, 5 na 7 ugboro; Ihe nkwụpụta nkwụsi ike ugbu a ọnụ ahịa kacha elu: ọnụ ọgụgụ dị mma Ir + na-adịghị mma Ir-; Capacitive ugbu a isi ebili mmiri, zuru voltaji, zuru ugbu a n'akuku akụkụ iche; Voltaji RMS; Eji ike oriri; |
Usoro nlele nke akara ngosi voltaji | Mmekọrịta waya: 40m (nwere ike ịgbatị) Mmekọrịta ikuku:> 400m (nwere ike ịgbatị) |
Batrị | Oge nchaji: > awa 6 Oge na-aga n'ihu na-arụ ọrụ: > 4 awa Ogologo oge ọrụ: > 8 awa |
Akụkụ | Isi ihe: 36cm*26cm*14cm Ngwa ngwabehi: 42cm*33cm*20cm |
Ibu | Isi nkeji: 5.0kg , Ngwa ngwa igbe: 9.0kg |