GDJS-65 Nhazi ihe mkpuchi ihe mkpuchi mkpuchi
A na-eji ya na-anwale arụmọrụ mkpuchi maka mkpuchi mkpuchi, akpụkpọ ụkwụ, akwa akwa, okpu, mkpanaka, Electroscope wdg. Ọ nwere ike ịnwale 6pcs mkpuchi mkpuchi mkpuchi / akpụkpọ ụkwụ n'otu oge, nakwa 5pcs mkpuchi mkpuchi.
Otu njikwa akwụkwọ ntuziaka
●Dijitalụ na ezigbo oge na-egosipụta voltaji HV, ugbu a LV, ihipu ụzọ 6 ugbu a na oge.
●Na mita ntapu nke ugbu a na mita nchebe karịrị ugbu a.
●Site na ngalaba njikwa mbugharị, wiring na nnwale dị mfe.
●Njikwa ntuziaka, nchekwa na ntụkwasị obi.
●Na efu, ike, ọrụ, oge egosi.
●Site na nchebe karịrị ugbu a, nchebe mmalite efu, ụda na ọkụ ọkụ, mgba ọkụ na-echekwa ike.
●Ụdị ngụ oge ọhụrụ, ogologo oge sara mbara.(1s-99h).
Atụmatụ ndị ọzọ
●HV isi iyi bụ mmanụ imikpu ụdị mgbanwe mgbanwe.(ụdị akọrọ na SF6 gas ụdị maka nhọrọ.)
●Ọ dị mma maka ịnwale mkpuchi mkpuchi mkpuchi (akpụkpọ ụkwụ), mkpanaka mkpuchi 6-110kV na 6-110kV electroscope.
●Iji mee ule maka mkpuchi mkpuchi mkpuchi na akpụkpọ ụkwụ, HV electrode bụ ụdị yinye, nke nwere ike imezi elu.Ihe bụ igwe anaghị agba nchara na CU/EpNi5bc ese, nke na-eme ka mwepu elu <10pc.A na-ebutekwa gbọmgbọm mkpuchi pcs 6pcs.
●The electrode nke mkpuchi akpụkpọ ụkwụ bụ red cooper voltaji-ekekọrịta ụdị, na HV n'ime ala akpụkpọ ụkwụ bụ hà nkesa.A na-enye bọọlụ nchara 4mm, anaghị eji ụzọ ọdịnala agbaba mmiri.
●Na mkpuchi mkpara guzo ime ka iguzogide voltaji na ntapu ule maka mkpuchi mkpanaka.(Nhọrọ)
●Iji ngwaọrụ nnwale elektrọskopụ mee ka voltaji mmalite, in-phase, nnwale nnyonye anya na-apụta maka elektrọskopụ.(Nhọrọ)
●Na electrode maka iguzogide voltaji na ntapu ule nke mkpuchi mkpuchi na blanketị.(Nhọrọ)
●Ngalaba njikwa na ngalaba HV dị iche iche, iji hụ na nchekwa.
●Ọ bụrụ na enwere ndakpọ ma ọ bụ karịa oke, a ga-ebipụ mmepụta HV ozugbo na mkpu.
●Enyere ikike: 5kVA
●Ntinye aka voltaji: AC220V± 10%, 50Hz±1
●voltaji mmepụta: 0-50kV
●Izi ezi voltaji: ≤ 2.0%(FS)
●LV dị ugbu a: 0-25A
●Ịgbapụta ugbu a: 0-20.0mA
●Mkpebi nke ntapu ugbu a: 0.1mA
●izi ezi ugbu a: ≤1.5%
●Ogologo oge: 0-99h
●Okpomọkụ gburugburu: -20℃-50℃