Nsonaazụ nyocha nke ugbu a nke mwepu akụkụ na akụrụngwa GIS na-egosi na n'ihi ike dielectric dị elu nke SF6 gas, ogologo oge nke mbelata nke ukwuu na ikuku SF6 dị elu na akụrụngwa GIS dị mkpụmkpụ, ihe dị ka nanoseconds ole na ole, na isi ife nwere obere oge.Oge ịrị elu bụ naanị ihe dịka 1ns.Ụdị mkpọda dị elu nke nwere ogologo oge dị mkpụmkpụ, gụnyere akara ruo GHz, ga-emepụta ebili mmiri electromagnetic na-eru na mkpuchi akụrụngwa GIS.Mkpọpu usu na-agba ọsọ dị elu na-aga site na waya na-agbanye ala, na mkpuchi na-ejikọta na ala.Na-enye voltaji dị elu ma na-ebute ebili mmiri electromagnetic na oghere gbara ya gburugburu.Mwepu nke akụkụ ga-emekwa ka mmụba na mberede na nrụgide nke gas ọwa, na-emepụta ebili mmiri ogologo oge ma ọ bụ ebili mmiri ultrasonic na gas nke ngwa GIS, na ụda ụda dị iche iche, dị ka ebili mmiri ogologo oge, ebili mmiri na-atụgharị na ebili mmiri elu, na-apụta na ígwè. shei.Mwepu nke obere na akụrụngwa GIS nwekwara ike ime ka gas SF6 mebie ma ọ bụ wepụta ìhè.Mgbanwe mmetụta anụ ahụ na kemịkal ndị a yana mwepu akụkụ bụ ihe ndabere maka nchọpụta ịntanetị nke ngwa GIS.Enwere ike kewaa ụzọ nchọpụta nke mwepu akụkụ na akụrụngwa GIS ụzọ abụọ: usoro nchọpụta ọkụ eletrik na usoro nchọpụta enweghị ọkụ.usoro, SF6 gas ire ere ụzọ nchọpụta ngwaahịa.
GDPD-300UF UHF Ihe nchọpụta mwepu akụkụ
Enwere ike iji HV Hipot GDPD-300UF UHF onye na-ahụ maka ọpụpụ akụkụ (UHF akụkụ mkpofu ngwa ngwa) na nchọpụta mwepu akụkụ nke sistemu ike, gụnyere mgbanaka voltaji, mgbanaka isi mgbanaka, voltaji / ihe ngbanwe dị ugbu a, onye ntụgharị (gụnyere nchọpụta steeti akọrọ). akụrụngwa dị ka transformers), GIS, n'elu ahịrị, cables, wdg, a na-atụle nhapụ nke ngwa eletriki site na-esonụ egosi.
Njirimara ngwaahịa nke UHF Partial Dischage Detector
Hazie sensọ dị iche iche iji nweta nchọpụta mwepu akụkụ nke ihe fọrọ nke nta ka ọ bụrụ akụrụngwa eletrik niile;
Onye ọrụ-enyi na enyi-igwe interface na-eme ka njikwa data nke ngwá ọrụ dị iche iche, gụnyere traceability nke akụkọ ihe mere eme data ọnọdụ, kehoraizin na vetikal data analysis, na-aghọta 360 ° keukwu nchoputa nke ngwá n'okpuru ule;
Ihe mmetụta ultrasonic wuru na voltaji ala na-agafe agafe (nke a na-akpọ TEV) ihe mmetụta, nke enwere ike ijikọ na sensọ pụrụ iche dị ka ihe ntụgharị, GIS, ahịrị elu, na eriri;
A na-anakwere usoro nchọpụta na-adịghị emerụ ahụ, ọ dịghị ike ọ bụla achọrọ n'oge ule ahụ, ọ dịghịkwa ihe ọzọ dị elu voltaji a chọrọ, nke dị mfe iji karịa ihe nchọpụta pulsed partial ipupu;
Ogologo bandwidth ule ule bụ 30kHz ~ 2.0GHz, nke dabara adaba maka ụkpụrụ nchọpụta nke eriri ugboro dị iche iche.