Insulating boots and gloves withstand voltage test device is one of the commonly used safety testing equipment in electrical engineering. It is mainly used to measure the withstand voltage performance of insulating devices such as insulating gloves and insulating boots to ensure the safety of electric workers during electrical work. The device consists of multiple parts, including high voltage generator, test car insulation support, test console, safety protection device and so on.
The high-voltage generator is the core component of the insulating boots and gloves withstand voltage test device, which can generate a high-voltage electric field to simulate the electrical pressure in the on-site working environment. There are two types of high-voltage generators commonly used: oil-immersed and dry-type. The oil-immersed high-voltage generator is relatively large and suitable for laboratory environments, while the dry-type high-voltage generator is small in size and easy to carry. Test it on the job site.

GDJS-A series intelligent insulating gloves (boots) hipot test set
The test car insulation bracket is erected with conductive items such as insulating gloves and insulating boots, and is generally made of insulating materials. The brackets can be divided into two types: fixed brackets and movable brackets. The fixed brackets are mainly used for the withstand voltage test of insulating gloves, while the movable brackets are suitable for different insulation devices such as the withstand voltage test of insulating boots.
The test console is another core component of the insulating boots and gloves withstand voltage test device. It is used to measure parameters such as voltage and current of the high-voltage electric field, and to test insulating gloves, Insulation devices such as insulating boots are tested for withstand voltage. Commonly used test instruments include voltmeters, ammeters, and resistance meters.
The safety protection device is an indispensable part of the insulating boots and gloves withstand voltage test device, and its main function is to protect the safety of testers. Safety protection devices include lightning protection devices, leakage protection devices, grounding protection devices, etc., which can effectively prevent high-voltage electric fields from harming testers.
The insulating boots and gloves withstand voltage test device is an indispensable test equipment for electric workers, which can effectively improve the safety of workers in electrical work. Through the in-depth understanding and application of high-voltage generators, insulating brackets, test consoles, safety protection devices and other components, the work safety of electric workers can be better protected, and the normal operation of electrical equipment can also be guaranteed.
Post time: Jun-02-2023