Technical Guide

Technical Guide

  • The detection range of the portable partial discharge detector for on-site detection

    The detection range of the portable partial discharge detector for on-site detection

    The portable partial discharge detector is a portable instrument used to detect and locate the partial discharge (PD) phenomenon that occurs internally or on the surface of electrical equipment (such as high-voltage cables, switch cabinets, transformers, insulators, etc.) due to insulation defect...
    Read more
  • Three-channel DC resistance tester test operation method

    Three-channel DC resistance tester test operation method

    I. Core Advantages: Why Choose Three-Channel? High measurement efficiency: Three-phase windings are charged and measured simultaneously, reducing the traditional several-hour work to just a few minutes. Higher measurement accuracy: Due to synchronous measurement, the temperatures of the three-pha...
    Read more
  • Knowledge sharing about series resonant reactors

    Knowledge sharing about series resonant reactors

    The fundamental reason for the slightly lower power factor on the input side of the frequency converter is fundamentally different from the low power factor of the three-phase motor with variable frequency. Series resonance occurs because the three-phase motor is a rational and objective electric...
    Read more
  • On-site usage method of SF6 gas recovery device

    On-site usage method of SF6 gas recovery device

    SF6 gas, due to its excellent insulation and arc-extinguishing properties, is widely used in power systems. However, during the installation, maintenance, and repair of electrical equipment, operations such as gas recovery, storage, charging, and discharging are necessary to ensure the normal ope...
    Read more
  • Introduction about AC Series Resonance Test System

    Introduction about AC Series Resonance Test System

    The generator AC withstand voltage test requires the use of power frequency voltage. The national standard defines the frequency of power frequency voltage as 45Hz to 65Hz. However, in many test scenarios, the generator is required to undergo an AC test of 50Hz ± 2Hz. Moreover, the generator stat...
    Read more
  • The role of series resonant reactors in resonant circuits

    The role of series resonant reactors in resonant circuits

    As the name suggests, an inductor is a component connected in series in a circuit (an inductor). In the industries of reactive power compensation and harmonic control, the series inductors are mainly those connected in series with capacitors. The series inductors and capacitors form a resonant ci...
    Read more
  • Explanation of the knowledge about the AC hipot test set

    Explanation of the knowledge about the AC hipot test set

    The AC withstand voltage resonance device is mainly designed and manufactured for the AC withstand voltage tests of primary electrical equipment in substations below 220kV. It can meet the AC withstand voltage tests of capacitive equipment such as transformers, GIS systems, SF6 switches, cables, ...
    Read more
  • The main characteristics of series resonance

    The main characteristics of series resonance

    The main characteristics of series resonance: 1.The operation is quite simple. It is divided into two types: automatic test and manual test. The former can automatically find the resonance point and automatically increase the voltage, while the latter is for manually finding the resonance point a...
    Read more
  • Detailed Explanation of the Differences between Series Resonance Test Equipment and Variable Frequency Series Resonance Test Equipment

    Detailed Explanation of the Differences between Series Resonance Test Equipment and Variable Frequency Series Resonance Test Equipment

    The principle of series resonance refers to the situation in a series circuit composed of resistors, inductors and capacitors. When the capacitive reactance XC is equal to the inductive reactance XL, that is, XC = XL, the voltage U and current I in the circuit are in phase. At this point, the cir...
    Read more
  • What is partial discharge?

    What is partial discharge?

    During the maintenance and monitoring of power systems, partial discharge, as a potential fault indicator, has gradually drawn significant attention from engineers and researchers. Its concealment and destructive nature make the understanding of partial discharge an important aspect in the manage...
    Read more
  • How to test the operating time with a relay protection tester?

    How to test the operating time with a relay protection tester?

    Relay protection devices, as key safety protection components in power systems, directly affect the safety and stability of power grid operation with their performance. Action time, as an important indicator to measure the response speed of relay protection devices, reflects the duration from the...
    Read more
  • In the AC withstand voltage test, how can we determine whether the test sample has been broken down?

    In the AC withstand voltage test, how can we determine whether the test sample has been broken down?

    The AC withstand voltage test is an indispensable part of the performance assessment of electrical equipment and insulating materials. Its core task is to verify the insulation strength and safety of the tested item under high voltage. Determining whether the tested item has been broken down is a...
    Read more

Send your message to us:

Write your message here and send it to us