Sistemụ nleba anya n'ịntanetị n'ịntanetị transformer mmanụ gas
GDDJ-DGA Transformer Oil Gas Analyzer bụ ngwaọrụ nleba anya n'ịntanetị maka gas gbazere na mmanụ mgbanwe dabere na teknụzụ chromatography gas.A na-ekpebi mmejọ nwere ike ime, wepụta njikere dị ka uru atọrọ site na sistemụ nyocha ọkachamara.
Ngwaọrụ na-anabata teknụzụ nlele njikwa kesara ma nwee nyocha onwe ya yana ọrụ mgbake onwe ya.Modul ọrụ ọ bụla bụ njikọ na-adịghị ike, na-arụ ọrụ onwe ya, na-ewere usoro rack, dị mfe maka mmezi injinia.
●Na-enweghị nlekọta, ọ dịghị mkpa iji dochie gas cylinder.
●Nchọpụta ntanetị n'ịchọta na ọnụego uto nke H2, CO, CO2, CH4, C2H4, C2H2, C2H6.
●Nhazi modular na kọmpat, dị mfe maka mmezi, yana nnukwu ohere, nwere ike itinye ngwa ngwa na ngwa nlekota ndị ọzọ.
●Ọnụ ọgụgụ nke nhicha okirikiri nke sampling mode, na-egosipụta ọnọdụ nke etisasịwo gas na mmanụ transformer.
●Pumpless agụụ degassing technology, ọ dịghị mkpa agụụ mgbapụta ma melite ntụkwasị obi na kwụsie ike nke usoro.
●Kọlụm chromatographic mgbagwoju anya pụrụ iche, iji meziwanye ogo nkewa nke ihe mejupụtara gas.
●Ihe nchọpụta linear pụrụ iche, data nleba anya dị adị ma bụrụ nke a pụrụ ịdabere na ya, nsonaazụ ule dị nso na data ụlọ nyocha.
●Ngalaba nọọrọ onwe ya n'ime chassis iji chịkwaa okpomọkụ na iru mmiri, wepụ mmetụta mpaghara na oge.
●Na elu data nnweta nkenke, ọ adopts △-ε 24-nọmba ADC na dijitalụ iyo.Ọ na-eji mmezi akpaaka iji nakọta spectrogram.
●Site na ngosipụta data dị iche iche na ụdị ajụjụ, mkpesa na eserese na-ewu ewu.Enwere ike ịchekwa data akụkọ ihe mere eme ruo afọ 10.
●Mgbanwe gburugburu ebe obibi siri ike, ngwa na-aga nke ọma na oyi, okpomọkụ dị elu, oke iru mmiri, ebe dị elu.
●Ike mgbochi nnyonye anya siri ike, ndakọrịta elektrọnik nwere ike imeju ọkọlọtọ dị mkpa.
●N'iji ọkwa abụọ nke ọrụ mkpu, enwere ike ibunye mgbaama mkpu.
●Usoro nyocha ngwa ngwa, usoro nleba anya kacha nta bụ nkeji 40, ndị ọrụ nwere ike ịtọ ya.
●Nkà na ụzụ nloghachi mmanụ zuru oke, n'oge usoro degassing, mmanụ mmanụ anaghị akpọtụrụ gas na-ebu chromatogram, iji ụzọ dị iche iche na-achịkwa, iji hụ na nkwụghachi azụ nke ihe nlele mmanụ na-emezu ihe ndị a chọrọ.
●Sistemụ nchoputa sistemu siri ike siri ike, a na-enye nsonaazụ site na usoro oke atọ ka mma, usoro David triangle na usoro eserese cube.
●Site na ụzọ nzikọrịta ozi dị iche iche iji nyefee data, RS485, IEC61850, GPRS nnyefe ikuku na ozi dị mkpirikpi na-etinye maka ịnyefe data.
●Nkwado Ethernet/njikọ ngwa anya, ịnyefe data, njikwa ngwaọrụ na ntọala n'iji dijitalụ zuru oke yana njikwa ime.
●Mmanya mmanụ/gasị akpaaka na ọrụ nhicha akpaaka dị.
Okpomọkụ gburugburu | -40 ℃~+ 70 ℃ | ||
iru mmiri gburugburu | Iru mmiri dị ala 5-95% (enweghị condensation) | ||
Nrụgide ikuku | 80kPa-110kPa | ||
Ịnye ọkụ | AC 220V± 10%, 50Hz | ||
Ngwa nlekota oru | H2, CO, CO2, CH4, C2H4, C2H2, C2H6, H2O, ọnụego uto na itinye uche | ||
Analysis na diagnostic ọrụ | Nyochaa ma chọpụta data nleba anya site na usoro oke atọ, usoro David triangle na usoro cube eserese.Enwere ike ịnye spectrogram mbụ. | ||
Min.okirikiri nchọpụta | 40-60mins, akọwara onye ọrụ, ndabara ugboro anọ n'ụbọchị. | ||
Ụdị nlele | Nlele ịgba ígwè, iji gosipụta ọnọdụ oge dị n'ime gas. | ||
Ụdị nkewa nke mmanụ na gas | Vacuum degassing mode, degassing ugboro atọ nọgidere. | ||
Ogologo ndụ nchekwa data | ≥ afọ 10 | ||
Ọnụọgụ gas nke ebu | Gas na-ebu onwe ya, anaghị akwụsị akwụsị n'afọ niile.Ọ dịghị mkpa dochie gas cylinder. | ||
Nyochaa gas | Oke nha | Min.nchọpụta | Njehie |
H2 | 2-2000 ppm | 1 ppm | ± 10% |
CO | 5-20000 ppm | 5ppm | ± 10% |
CH4 | 0.2-2000 ppm | 0.2 ppm | ± 10% |
C2H4 | 0.2-2000 ppm | 0.2 ppm | ± 10% |
C2H6 | 0.2-2000 ppm | 0.2 ppm | ± 10% |
C2H2 | 0.2-2000 ppm | 0.2 ppm | ± 10% |
CO2 | 25-20000 ppm | 25 ppm | ± 10% |
H2O | 1-800 ppm | ||
Okpomọkụ mmanụ | -40 ℃ ~ 200 ℃ | ||
Ngụkọta oke ikuku | 0.2-15% | ||
Mgbakọta hydrocarbon | 1-8000 ppm | ||
Nkwụsi ike (njehie nha) | N'otu ọnọdụ ule ahụ, njehie abụghị ihe karịrị 10% maka otu ụdị mmanụ.(obere itinye uche) | ||
IP klas | IP66 |
Elu | ≤3000m |
Ọnọdụ okpomọkụ | -10 ℃ ~ + 45 ℃ (n'ime ụlọ);-40℃~+70℃(n'èzí) |
Oke.kwa ụbọchị okpomọkụ iche | 25 ℃ |
Oke.iru iru mmiri | 95% (nkezi kwa ụbọchị);90% (nkezi kwa ọnwa) |
Nrụgide ikuku | 86kPa ~ 106kPa |
Ikike mgbochi ujo | Osooso kwụ ọtọ 0.30g;vetikal osooso 0.15g |
gburugburu nwụnye | Ntinye ime ụlọ.Ime ụlọ ahụ ga-eji ihe mkpuchi ikuku, enweghị ihe mkpuchi, na-enweghị ihe mgbochi static. |
Ike ọkọnọ (AC) akwadoro | 220V/100V, njehie ekwe omume ± 20% (harmonics), ngụkọta mgbagha voltaji ọnụego ≤8%. |
Ike ọkọnọ (DC) akwadoro | 220V/110V, ikike mgbanwe dị iche iche ± 20%. |
Enyere voltaji AC | 57.7V / 100V / 220V, ibu ibu ikike bụ 1.2times nke gosiri voltaji, ọnụ ọgụgụ kasị elu ≥2. |
Enyere AC ugbu a | 1A/5A, ikike ibu ibu bụ 1.2 ugboro nke egosiputara ugbu a, na-arụ ọrụ na-aga n'ihu, ọnụ ọgụgụ kacha elu ≥3. |
Ugboro ugboro | 50Hz, njehie ekwe ekwe -5% ~+5%. |
Ịnye ọkụ
Ike ọkọnọ nke sistemụ nleba anya ọnọdụ ọdụ ụgbọ mmiri kwesịrị ịdị mma ma bụrụ nke a pụrụ ịdabere na ya, yana akụrụngwa njikwa oyi akwa ọdụ kwesịrị ịbụ 220VAC na-enweghị nkwụsịtụ ike ọkọnọ (UPS).Igwe nleba anya ọ bụla na oyi akwa usoro na-akwado ya site na sistemụ AC 220V.
Nchekwa ọkụ, mgbada, mgbochi nnyonye anya
Usoro nlekota ọnọdụ ọdụ ụgbọ ala ga-enwe usoro nchebe megide oke voltaji.
Enweghị okporo ala dị iche iche maka sistemu nlekota ọnọdụ.Dị ka ụkpụrụ nke "n'otu ebe grounding", a na-ejikọta waya ala n'otu ebe nke isi ihe ntanetị nke substation.
A ga-etinye ngwaọrụ nchekwa ihe karịrị voltaji na ọkụ ọkụ 220V AC, ahịrị nzikọrịta ozi na njedebe na-eduga nke netwọkụ ala, na paramita ngwaọrụ nchebe ga-adaba na ndeksi arụmọrụ mkpuchi nke akụrụngwa.
Ekwesịrị ịgbado chassis, kabinet na oyi akwa mkpuchi nke sistemu ọnọdụ nleba anya nke ọma.Njikọ dị n'etiti usoro nhazi nke usoro nlekota ọnọdụ, njikọ dị n'etiti usoro nhazi na oyi akwa njikwa ọdụ, na njikọ dị n'etiti ọdụ ụgbọ mmiri nke ngwaọrụ ga-adịpụrụ adịpụ.
A na-etinye ngwaọrụ ahụ n'ime ụlọ na-enweghị ihe mkpuchi electromagnetic.Ngwa ahụ n'onwe ya kwesịrị izute ihe ndị chọrọ nke mgbochi-electromagnetic field nnyonye anya na electrostatic mmetụta.N'ihe gbasara oke ọkụ, oke ọkụ na-arụ ọrụ na mmejọ mkpirisi nke akụrụngwa nke mbụ, akụrụngwa agaghị arụ ọrụ nke ọma, akụrụngwa niile ga-ezute ihe mgbochi nnyonye anya ndị a:
1) Maka mgbapụta electrostatic, ọ dabara na GB/T 17626-4-2 klas 4.
2) Maka mpaghara electromagnetic radieshon, ọ dabara na GB/T 17626-4-3 klas 3.
3) Maka ngwa ngwa nwa oge, ọ dabara na GB/T 17626-4-4 klas 4.
4) Maka ịwa ahụ, ọ dabara na GB/T 17626-4-5 klas 3.
5) Maka ntụzịaka nke induction electromagnetic, ọ dabara na GB/T 17626-4-6 klas 3.
6) N'ihi na ike ugboro electromagnetic field, ọ kwekọrọ GB/T 17626-4-8 klas 4.
7) N'ihi na pulse electromagnetic field, ọ kwekọrọ GB/T 17626-4-9 klas 5.
8) N'ihi na damped oscillating magnetik, ọ kwekọrọ GB/T 17626-4-10 klas 5.
9) Maka ebili mmiri na-agbagharị agbagharị, ọ dabara na GB/T 17626-4-12 klas 2 (ọdụ ụgbọ mmiri).
Mba. | Aha akụrụngwa | Nkọwapụta | Qty | kwuo |
1 | Sistemụ nleba anya n'ịntanetị nke Transformer Mmanụ Gas | 535*600*1100 | 1 | |
2 | Flange | Dabere n'ọdụ ụgbọ mmiri nke transformer | 2 | |
3 | Igwe anaghị agba nchara tube | Φ6*30M | 1 | |
4 | eriri anya | Multimode 4-isi, 200M | 1 | |
5 | Igbe njedebe | 2 | ||
6 | Jumper | SC-SC | 2 | |
7 | Ihe ntụgharị eriri | multimode | 1 | |
8 | eriri Ethernet | 0.5M | 2 | |
9 | Ịghasa | M12*1.25M, Φ6 | 2 | |
10 | Mgbasa skru | M10*100 | 4 | |
11 | Igodo kabinet | 2pcs | 1 | |
12 | Kaadị eriri | 4pcs + ọtụtụ eriri eriri nylon | 1 | |
13 | Igwe anaghị agba nchara tube | Φ3*2M | 1 | |
14 | Pipe mkpuchi na ihe ndị ọzọ | Igwe mkpuchi mkpuchi Φ6 * 2M 4pcs, Au teepu 50 * 25M 1roll, igwe anaghị agba nchara 8 * 32 2pcs | 1 |