Ntụle ule VLF AC Hipot 80kV
Nnwale iguzogide voltaji bụ ule mgbochi dị mkpa maka akụrụngwa eletrik.E kewara ya ụzọ abụọ: AC na DC na-eguzogide ule voltaji.Enwere ike kewaa ule AC n'ime ugboro ike, ugboro mgbanwe na 0.1Hz dị obere ule, n'ime nke IEC kwadoro nke ikpeazụ, n'ihi uru ya dị ịrịba ama.
Nke a bụ ntụnyere maka DC, Frequency Power, Frequency Variable, na 0.1Hz ule.
Akụkụ | DC | Ugboro ike | Ugboro mgbanwe | 0.1Hz |
Nhata | ogbenye | nke ọma | nke ọma | nke ọma |
Mmebi mkpuchi | ike | ntakiri | ntakiri | ntakiri |
Nchekwa ọrụ | dịtụ ala | dịtụ ala | dịtụ ala | elu |
Nsogbu waya | mgbagwoju anya | mgbagwoju anya | kacha mgbagwoju anya | mfe |
Olu | kacha nta | kasị ukwuu | nnukwu | obere |
N'ezie ule VLF bụ nnọchi maka ule ugboro ike.Ọ dabara maka ịnwale akụrụngwa eletrik nwere nnukwu ikike (dị ka eriri ọkụ, ike ike, moto, na jenerato).
Ọgbọ ọhụrụ nke usoro VLF 0.1Hz VLF AC Hipot Test Set mepụtara site na HV Hipot nakweere sistemụ nnwale ikike ọgụgụ isi "Smart Quick" (Soft No. 1010215, akara ndebanye aha ụghalaahịa 14684781), ụlọ ọrụ HV HIPOT webatara ngwa elektrọnik nke mba ụwa kachasị ọhụrụ na nke teknụzụ microcontroller ARM7 kachasị ọhụrụ, na-ebelata nha na ịdị arọ nke akụrụngwa.Arụ ọrụ dị mfe, na arụmọrụ ka kwụsie ike.
●Teknụzụ dị elu na-anakwere teknụzụ mgbanwe dijitalụ, njikwa microcomputer zuru oke, nkwalite voltaji, mgbada, nha, nchekwa, wdg.
●Akụkụ njikwa na akụkụ voltaji dị elu nakweere nhazi nhazi nke agbakwunyere, yana naanị waya voltaji na waya ala ka achọrọ iji jikọọ na ngwaahịa a nwalere na-enweghị eriri njikọ etiti.
●Ụdị ụdị trolley dị mma maka njem n'ebe dị iche iche na-arụ ọrụ, na obere nha ya na ịdị arọ ya na-arụ ọrụ nke ọma n'èzí (80kV).
●Nchekwa n'elu voltaji na nchebe dị ugbu a.Oge ime ihe adịghị ihe karịrị 10ms.
●A na-ejikọta ngalaba njikwa na ihe nkwalite na obere voltaji, yana njikwa ikewapụ fotoelectric, nchekwa na ntụkwasị obi iji.
●A nakweere sekit nzaghachi adịghị mma emechiri emechi.Enweghị ikike na-ebili n'oge mmepụta.
●Ihuenyo mmetụ capacitive, ihe ngosi eserese LCD, nchekwa akpaka, na mbipụta.
●Enwere ike ịhọrọ 0.1Hz, 0.05Hz na 0.02Hz, nke na-eme ka ọnụọgụ ule dị ukwuu.
●Oke voltaji: 80kV
●Ule ule: 0.1Hz, 0.05Hz na 0.02 Hz (a na-ahọrọ)
● Maximum load capacity: 1.1μF@0.1Hz / 2.2μF@0.05Hz / 5.5μF@0.02Hz
●Nkezi nha nha: 3%.
●Njehie ọnụ ahịa kacha elu voltaji: ≤3%.
●Mgbanwe ụdị nke voltaji: ≤5%.
●Ebe ọrụ: ime ụlọ ma ọ bụ n'èzí;-10℃-+40℃;85% RH
●Ngwa ngwa: 20A
●Ike ọkọnọ: 220V ± 10%, 50Hz ± 5% (Ọ bụrụ na ị na-eji a obere generator, jide n'aka na mmepụta voltaji na ugboro bụ kwụsiri ike. Ike> 3kW, ugboro 50Hz, voltaji 220V± 5%).
●Ike nke ihe a nwalere agaghị agafe oke.gosiri capacitance nke ngwá.