Sistemụ nnwale voltaji GDCY (100kV-7200kV)

●Okpokoro njikwa na nha.
●Na-akpali Voltage Generator.
●Ngalaba Nchaji HV DC.
●Nkesa voltaji na-adịghị ike
Ọkwa voltaji na-akpali akpali | 100kV-7200kV |
Ọkọlọtọ ọkụ ife | 1.2±30%/50±20%µS |
Oscillation kacha elu | <5% |
Ọkọlọtọ ngbanwe ife | 250±20%/2500±60%µS |
Oge n'ihu mebere nke oke ọkụ na-efegharị | ≤15µS |
Virtual n'ihu oge oscillating ịmafe ife na mebere n'ihu oge oscillating ịmafe mkpali ife | 15µS-1mS |
Opekempe mmepụta voltaji | ≥10% A |
Ịchaji voltaji akwụghị ụgwọ | <±1% |
Oke mmekọrịta | ≥20% |
Ọnụego mwepu na-emekọrịta ihe | <2% |
Oke mgbanye | 10% ~ 100% |
Oge ọrụ | ≥70% UN na-akwụsị ọrụ (ụgwọ-nfufe 300s / oge) <70% nn ọrụ na-aga n'ihu (ụgwọ-nfufe 120s / oge) |
arụmọrụ Generator: ọkụ ọkụ (enweghị ibu) | ≥90% |
Oge ịkụcha | 2 ~ 5µS |