GDPD-414 Ihe nchọpụta mwepu akụkụ akụkụ

GDPD-414 Ihe nchọpụta mwepu akụkụ akụkụ

Nkọwa nkenke:

The GDPD-414 Portable Partial Discharge Detector nakweere Sistemụ nyocha ike ọgụgụ isi ngwa ngwa, ma bụrụ ngwa nyocha mwepu mpaghara maka akụrụngwa mkpuchi ọkụ dị elu.

 

 

 


Nkọwa ngwaahịa

Mkpado ngwaahịa

GDPD-414 Portable Partial Discharge Detector01
GDPD-414 Portable Partial Discharge Detector02
GDPD-414 Portable Partial Discharge Detector03

Isi
otu

Ihe mmetụta UHF,
ụdị okirikiri,dị mma maka GIS

Ihe mmetụta UHF, ụdị rektangulu, dabara maka eriri ọkụ, ihe ntụgharị, mgba ọkụ

GDPD-414 Portable Partial Discharge Detector04
GDPD-414 Portable Partial Discharge Detector05
GDPD-414 Portable Partial Discharge Detector06

HFCT, dabara maka eriri ọkụ, transformer

Ihe mmetụta TEV,
adabara maka switchgear

Ihe mmetụta Ultrasonic, dabara adaba maka ndị na-agbanwe agbanwe, switchgear

GDPD-414

Foto ndị dị n'elu bụ naanị maka ntụnye aka na mbụ.

The GDPD-414 Portable (GDPD-414H handheld) Partial Discharge Detector nakweere usoro nnwale ike ọgụgụ isi ngwa ngwa (Soft No. 1010215, akara ndebanye aha ụghalaahịa 14684781 (14684481)).Ọ nwere ike ịhazigharị sensọ dị iche iche dịka ngwaahịa dị iche iche ga-anwale.TEV, ultrasonic na HFCT kwesịrị ekwesị maka nchọpụta mwepu akụkụ nke elu voltaji switchgear na mgbanaka netwọk ụlọ;Ultrasonic na UHF dabara maka ịchọpụta GIS;Ultrasonic na HFCT dabara adaba maka ịnwale eriri ọkụ.Usoro nyocha nke ọkachamara wuru n'ime ya nwere ike nyochaa data nyocha ma kpee ike iwepụ ike na akụkụ ndị nwere ike ime.A na-eji ya n'ọtụtụ ebe na ike eletrik na ụgbọ okporo ígwè.

GDPD-414 Portable Partial Discharge Detector07

Ihe mmetụta Ultrasonic na TEV (2-na-1)

Atụmatụ

Nabata bọọdụ nlele DSP/FPGA dị elu, nweta data synchronous ọwa 4.
Sistemụ ngwanrọ: ngwanrọ nyocha dabere na sistemụ agbakwunyere ARM
Enwere ike ịhazi ọwa 6/8/16
Mbadamba ụrọ 8.1 inch ma ọ bụ akwụkwọ ndetu Thinkpad dị ka nhọrọ
Enwere ike ịhazi ọwa 6/8/16 dị ka ihe ndị ahịa si dị iche iche chọrọ.
Nwere ike igosipụta maapụ PRPS na PRPD, eserese ellipse, maapụ ọnụego mwepu, maapụ QT, maapụ NT, maapụ mkpokọta PRPD, maapụ faị-QN nke ọwa mgbaàmà ọ bụla.
 Ụdị ngosi agba atọ nke ọbara ọbara, odo na acha anụnụ anụnụ na-egosi ịdị njọ nke mwepu akụkụ.

 

Ndị ahịa nwere ike họrọ sensọ dị ka ihe anwalere dị iche iche si dị:

Ihe mmetụta

TEV/AE/HFCT

AE/UHF

AE/HFCT

 

Ihe nwalere

HV Swichgear na mgbanaka netwọk kabinet

 

GIS

 

USB

 

 

Nkọwa GDPD-414 / GDPD-414H
Onye nnabata akara PD
Ugboro CPU arụ ọrụ 1.2GHz / 800MHz
Sistemụ nrụọrụ Sistemụ arụ ọrụ agbakwunyere Linx
Ọdụ ụgbọ mmiri netwọk ikuku ọdụ ụgbọ mmiri LAN
Ọdụ ụgbọ mmiri ikuku ikuku WiFi ikuku arụnyere (nhọrọ)
Ebe nchekwa sistemụ na-agba ọsọ 1G / 512M
Ebe nchekwa sistemu 512M / 256M
Ugboro nnweta data 250MHz / 80MHz
Ọwa nchọpụta Ultrasonic
Oke nha 0-60mV
Oke nchọpụta ugboro ugboro 20 ~ 200kHz
Ọwa nchọpụta UHF
Ugboro nchọpụta 300 ~ 1800MHz / 300 ~ 1500MHz
Oke nha -80-10dBm
Njehie ±1dBm
Mkpebi 1dBm
Ọwa nchọpụta HFCT
Oke ugboro 0.5 ~ 100MHz
Njehie ±1dB
Oke dị ike 60dB
Oke nha 0-100mV
izi ezi 1dB
Ọwa nchọpụta TEV
Oke ugboro 3 ~ 100MHz
Njehie ± 1dB / mV
Mmetụta 0.01mV
Oke nha 0-60dB / mV
Mkpebi 1 dBm / mV
Batrị
Batrị arụnyere n'ime ya Batrị lithium, 12V, 4400mAh / batrị lithium, 12V, 2000mAh
Jiri oge mee ihe ihe dị ka awa 8 / ihe dị ka awa 6
Oge nchaji Ihe dị ka awa 2
Nchekwa batrị N'elu-voltaji na nchebe dị ugbu a
Ịchaji batrị
Egosiri voltaji 12.6V
Nchaji mmepụta ugbu a 2A
Ọnọdụ okpomọkụ na-arụ ọrụ -20 ℃-60 ℃
iru mmiri na-arụ ọrụ <80%
GDPD-414H Ngosi ihe ngosi ejiri aka (ọkwa ụlọ ọrụ)
CPU Intel Quad Core Atom Z3735F
GPU Ihe eserese Intel HD (Gen7)
Flash 32GB
RAM 2GB
Sistemụ nrụọrụ Windows 10
Ngosipụta 8.1 inch 1280 × 800 IPS ihuenyo
Njikọ netwọkụ Wifi na Bluetooth
Batrị 3.7V 8500mAH polymer lithium ion batrị
Laptọọpụ Thinkpad ma ọ bụ PC mbadamba
Nha
Nha ngwa ngwa / Nha nnabata PD 395mm * 295mm * 105mm / 240mm * 165mm * 55mm
PD nnabata ibu 3kg / 0.65kg
PD hose case size / Ngosipụta ọnụ ọnụ mbadamba 570mm * 360mm * 240mm / 395mm * 295mm * 105mm
Gosipụta ịdị arọ mbadamba nkume 0.85 n'arọ
N'ozuzu igbe igbe 570mm * 360mm * 240mm
Ebe ọrụ
Ọnọdụ okpomọkụ na-arụ ọrụ -20 ℃ ~ 50 ℃
iru mmiri gburugburu 0 ~ 90% RH
IP larịị 54

GDPD-414H Ihe nchọpụta mwepu akụkụ akụkụ aka

GDPD-414H-Handheld-Partial-Discharge-Detector1
GDPD-414H-Handheld-Partial-Discharge-Detector01
GDPD-414H-Handheld-Partial-Discharge-Detector
GDPD-414H-Handheld-Partial-Discharge-Detector2
GDPD-414H Handheld Partial Discharge Detector5
GDPD-414H Handheld Partial Discharge Detector4

  • Nke gara aga:
  • Osote:

  • Zitere anyị ozi gị:

    Dee ozi gị ebe a ziga anyị ya

    Zitere anyị ozi gị:

    Dee ozi gị ebe a ziga anyị ya