Ngwa ule voltaji dị elu

  • Partial Discharge Test System GIT series

    Sistemụ Nleba Mwepu akụkụ GIT

    A na-eji usoro GIT eme ihe maka voltaji dị elu, akụrụngwa ike GIS nwere mkpuchi na-eguzogide ule voltaji, nnwale mwepu akụkụ na ule mgbanwe GIS, dabara maka ọdụ GIS, onye na-emepụta akụrụngwa GIS, onye na-emepụta ihe mkpuchi ọkụ eletrik.

     

     

     

     

     

  • Partial Discharge Test System GDYT series

    Sistemụ Nleba Mwepu akụkụ GDYT

    A na-eji ya eme ihe n'ichepụta ọkụ eletrik, ngalaba ọrụ ike, ụlọ ọrụ nyocha na mahadum.

     

     

  • PD free Variable Frequency Test System

    Sistemụ Nleba Ọdịnihu nke PD efu

    GDYT-350kVA / 70kV PD free Resonant Test Sistemụ mejupụtara PD free agbanwe ugboro ike ọkọnọ, HV nlele igbe, excitation transformer, iche iche transformer, Resonant reactor, na capacitive voltaji nkesa.

     

     

     

     

     

  • AC Dielectric Test Equipment with manual control unit GDYD-D

    Ngwa ule AC Dielectric nwere ngalaba njikwa ntuziaka GDYD-D

    Nnwale AC Hipot bụ ụzọ dị irè na kpọmkwem iji nwalee ike mkpuchi maka ngwa eletriki, ngwa ma ọ bụ igwe.Ọ na-enyocha ntụpọ ndị dị ize ndụ nke na-eme ka akụrụngwa eletrik na-aga n'ihu na-arụ ọrụ.

  • VLF AC Hipot Test Set

    Ntọala ule VLF AC Hipot

    Nnwale iguzogide voltaji bụ ule mgbochi dị mkpa maka akụrụngwa eletrik.Ọ na-ekewa ụzọ abụọ: AC na DC idi voltaji ule.

  • AC Dielectric Test Equipment with manual control unit GDYD-M

    Ngwa ule AC Dielectric nwere ngalaba njikwa ntuziaka GDYD-M

    Ngwa a na-ahụkarị gụnyere nnwale nke mgbanwe, switchgear, cables, capacitors, airal motors platforms, brik osisi osisi na-ekpo ọkụ, karama agụụ na ihe ndị ọzọ metụtara ya dị ka ndị na-egbochi agụụ, blanketị, eriri, gloves, hydraulics hose, ngwá ọrụ na-emepụta ihe na-emepụta ihe.

  • VLF AC Hipot Test Set 80kV

    Ntụle ule VLF AC Hipot 80kV

    Nnwale iguzogide voltaji bụ ule mgbochi dị mkpa maka akụrụngwa eletrik.Ọ na-ekewa ụzọ abụọ: AC na DC idi voltaji ule.

  • Insulation Materials Hipot Test Set GDJS-65

    Tọọ ihe nlere mkpuchi mkpuchi Hipot Nnwale GDJS-65

    A na-eji ya na-anwale arụmọrụ mkpuchi maka mkpuchi mkpuchi, akpụkpọ ụkwụ, akwa akwa, okpu, mkpanaka, Electroscope wdg Ọ nwere ike ịnwale 6pcs mkpuchi mkpuchi mkpuchi / akpụkpọ ụkwụ n'otu oge, nakwa 5pcs mkpuchi mkpuchi.

  • DC High Voltage Generator GDZG-300

    DC High Voltage Generator GDZG-300

    GDZG-300 usoro nke DC high voltaji tester na-anwale DC elu voltaji maka zinc oxide ọkụ arrester, magnetik ịfụ arrester, ike cables, generators, transformers, switches, na ndị ọzọ na ngwá, nke kwesịrị ekwesị maka ọkụ eletrik alaka alaka, ike ngalaba nke ụlọ mmepụta ihe, ngalaba nyocha sayensị, okporo ụzọ ụgbọ oloko, ụlọ ọrụ kemịkalụ, ụlọ ọrụ ọkụ.

  • DC Hipot Test Set GDZG-S

    Tọọ Nnwale DC Hipot GDZG-S

    Usoro GDZG-S bụ ngwá ọrụ nke ule DC voltaji na DC ntapu ugbu a nke mmiri jụrụ generator na ọnọdụ nke mmiri site, nke kpamkpam imeri nsogbu nke ogologo igbu mmiri oge, ala mmiri siri ike nkụ, mfe ime ka arcing n'ime eriri igwe. .Ngwaọrụ ahụ dị ọkụ, wiwi dị mfe ma dị mfe ịgụ.A na-emepụta voltaji akwụ ụgwọ nke polarization ozugbo site na ikpe ahụ.

  • 50kV AC DC Dielectric Test Equipment GDYD-53D

    Ngwa ule 50kV AC DC Dielectric GDYD-53D

    Nnwale AC hi-pot bụ ụzọ dị irè na kpọmkwem iji nwalee ike mkpuchi maka ngwa eletriki, ngwa, ma ọ bụ igwe.Ọ na-enyocha ntụpọ ndị dị ize ndụ nke na-eme ka akụrụngwa eletrik na-aga n'ihu na-arụ ọrụ.

  • AC DC High Voltage Divider

    AC DC High Voltage Divier

    GDFR-C1 usoro AC / DC dijitalụ mita bụ na-saịtị ngwá, nke na-anwale ma AC na DC voltaji.Ọ mejupụtara nkesa voltaji na ngwaọrụ nha.

     

12Ọzọ >>> Peeji nke 1/2

Zitere anyị ozi gị:

Dee ozi gị ebe a ziga anyị ya