N'etiti ọnwa Disemba, ndị ahịa Jiangsu zụtara akụrụngwa nyocha kemịkalụ mmanụ n'aka ụlọ ọrụ anyị.
Mgbe atụnyere ọtụtụ ndị na-emepụta ihe, onye ahịa ahụ nyochara ike ụlọ ọrụ ahụ, ma mesịa kpebie ịbanye nkwekọrịta ịzụta na ụlọ ọrụ anyị.Ozugbo e debanyere nkwekọrịta ahụ, ngalaba mmepụta nke HV HIPOT na-ahazi ngwa ngwa ma rụọ ọrụ oge ọrụ iji na-ebuga ngwongwo dị elu ma nyefee ya ndị ahịa.Akụrụngwa onye ahịa zụtara oge a gụnyere:GDC-9560B ike sistemụ mkpuchi mmanụ gas chromatograph analyzer.GD6100 transformer mmanụ tan delta tester,GDSZ-402 akpaka mmanụ acid uru tester, GDW-106 ihe nleba anya igirigi mmanụ, GDOT-80A ihe nleba anya mmanụna akụrụngwa ndị ọzọ.
Ihe nyocha chromatographic mmanụ pụrụ iche maka sistemu ike eletriki bụ kọmpụta na-achịkwa ọtụtụ ebumnuche dị elu usoro nke ihe nyocha chromatographic mmanụ pụrụ iche maka sistemụ ọkụ eletrik.GDC-9560B chromatograph mmanụ pụrụ iche maka sistemụ ọkụ eletrik nwere sistemụ njikwa akpaka zuru oke.Attenuation na efu mmezi nke sekit nha na-achịkwa bọtịnụ niile, na nkwụsi ike na ntụkwasị obi dị elu.A na-ejikarị ya na ike eletrik, mmanụ ala, ụlọ ọrụ kemịkalụ, metallurgy, nchekwa gburugburu ebe obibi, nri, ọgwụ, ahụike na mpaghara nyocha sayensị dị iche iche.
GDC-9560B ike sistemụ mkpuchi mmanụ gas chromatograph analyzer
Atụmatụ
Arụ ọrụ dị mma: ikpo okwu na-arụ ọrụ nke China WINDOWS, interface windo Chinese zuru oke, ihe na-eme ozugbo yana enyemaka n'ịntanetị, nke dị mma maka ndị ọrụ ịmụta na iji.
Ezigbo oge: nnweta data n'ezie n'okpuru ezigbo WINDOWS gburugburu, nleba anya n'otu oge ọwa abụọ, ezigbo oge ngosi nke oge njigide kacha elu chromatographic.
Elu nkenke: 24-bit kaadị nkwụnye A/D dị elu, oke ntinye: -1v~+1v.
Mmegharị: 0.006%.
Mepee njikwa data: chekwaa ozi akụrụngwa metụtara yana ozi data nsonaazụ nyocha, dabara adaba ịgbakwunye, gbanwee, ihichapụ na ịgụ na weghachite ma ọ bụrụ na ịchọrọ.Ụdị data mepere emepe dabara adaba maka ikesa data ọtụtụ ndị ọrụ iji kwado ohere nke ngwanrọ njikwa nchekwa data ndị ọzọ yana mkpa eweghachi nke ngalaba njikwa.
Nchọpụta mmejọ akpaaka: mgbe nyochachara, ọ ga-egosi ozugbo na ọ gafere oke, nye nchoputa ọnụọgụ atọ nke dabara n'ụkpụrụ mba, eserese TD, eserese mkpokọta akụrụngwa na ụzọ nyocha mmejọ ndị ọzọ.
N'ụzọ dị mfe qualitatively: tebụl njirimara kacha elu nwere ike dezie ya na-akpaghị aka ma ọ bụ aka.A na-agbakọ ihe mgbazi na-akpaghị aka, yana ọtụtụ mmezi nwere ike gbakọọ nkezi.
Nchọpụta kacha elu na-agbanwe agbanwe na ikike nhazi: Enwere ike ịmata, ihichapụ na mezie ọnụ ọgụgụ kacha elu Chromatographic maka igbubi ntọala site na ịtọ ntọala na mmemme oge ma ọ bụ jiri aka dozie ha.Gbaa mbọ hụ na nsonaazụ nyocha ziri ezi.
Ọrụ obibi akwụkwọ na-agbanwe agbanwe: Nye akụkọ nsonaazụ n'ụdị edobere yana ụdị ndebiri omenala.
Ịnabata teknụzụ dị elu 10/100M adaptive Ethernet nkwurịta okwu, na arụnyere na IP protocol tojupụtara, nke mere na ngwá nwere ike mfe ịghọta ogologo data nnyefe site Enterprise si esịtidem LAN na Internet;ọ na-eme ka nguzobe nke ụlọ nyocha ahụ dị mfe ma na-eme ka ụlọ nyocha ahụ dị mfe nhazi nhazi nke data nyocha.
Ime ime nke ngwá ọrụ ahụ nwere usoro njikọ njikọ onwe 3, nke nwere ike jikọọ na nhazi mpaghara (saịtị ụlọ nyocha), ndị nlekọta otu (dị ka ndị isi ngalaba nyocha nke ọma, ndị na-ahụ maka ụlọ ọrụ mmepụta ihe, wdg), na ndị nlekọta dị elu (dị ka nchebe gburugburu ebe obibi). Ụlọ ọrụ, ụlọ ọrụ nlekọta teknụzụ, wdg), Ọ dị mma maka onye nlekọta otu na onye nlekọta dị elu iji nyochaa ọrụ nke ngwá ọrụ ma nyochaa nsonaazụ data ozugbo.
Nhọrọ NetChromTM arụ ọrụ nke ngwá ọrụ nwere ike ịkwado ọrụ nke ọtụtụ chromatographs n'otu oge, ghọta nhazi na njikwa data, mee ka njikwa akwụkwọ dị mfe, ma belata ego ụlọ nyocha nke onye ọrụ na ụgwọ ọrụ ruo n'ókè kasị ukwuu.
Sistemu ahụ nwere sistemụ arụ ọrụ nke China na Bekee, ndị ọrụ nwere ike ịgbanwe n'onwe ha dịka mkpa ha siri dị.
Enwere ike ịkpọ mpaghara njikwa okpomọkụ n'efu site n'aka onye ọrụ, nke dị mma maka onye ọrụ iji.
Ngwá ọrụ ahụ na-ejikọta ụdị ọrụ nhazi multi-processor na-arụ ọrụ iji mee ka ngwá ọrụ ahụ kwụsie ike na ntụkwasị obi;ọ nwere ike izute nyocha nke mgbagwoju anya samples, na nwere ike kwadebere na a dịgasị iche iche nke elu-arụmọrụ nchọpụta, dị ka FID, TCD, ECD, na FPD, na ruo anọ detector nwere ike tinye n'otu oge.A pụkwara iji ihe nchọpụta ndị ọzọ mee ihe, nke na-eme ka ọ dị mfe ịzụta na wụnye ihe nchọpụta ndị ọzọ mgbe azụrụ ngwá ọrụ.