GDSL-A akpaghị aka 3-phase nke isi ihe nrịbama nnwale ọkpụkpọ
GDSL-A Series 3-phase Primary Injection Test Set with Temperature Test bụ ezigbo akụrụngwa maka ịnwale ngwaọrụ dị ugbu a na ụlọ ọrụ ọkụ na ọkụ eletrik, ejiri ya na ụlọ ọrụ ọkụ, ọdụ nkesa ike, nrụpụta eletrik na ụlọ ọrụ nyocha, yana njirimara ndị a. nke obere nha, ịdị arọ dị arọ, ojiji dị mfe na mmezi.
-
GDHL-200A (GDHL-100A) Micro-Ohmmeter ọhụrụ
GDHL-200A (GDHL-100A) Micro-Ohmmeter na-ọtụtụ ebe iji tụọ akaghị eguzogide na kọntaktị iguzogide maka weld nkwonkwo, cables, na dị iche iche HV switches n'ime ike ụlọ ọrụ.
-
GDHL-200B / GDHL-500B / GDHL-600B Onye Nleta Nguzogide Kọntaktị (Microhm)
● Ndị na-agbaji sekit dị elu, nke etiti na nke dị ala
● Igwe ọkụ na-ekpochapụ elu, etiti na obere voltaji
● Njikọ mmanya ụgbọ ala dị elu ugbu a
● USB & nkwonkwo ịgbado ọkụ
Ọ dabara maka ịdị elu ugbu a, nha micro ohm.
-
GDHL-100HS 100A Onye Nnwale Nguzogide Kọntaktị ejiri aka
A na-ejikarị ngwaahịa a maka nguzogide kọntaktị nke kọntaktị mgba ọkụ na nha nguzogide micro-ohm ndị ọzọ, na ọsọ ule na-agba ọsọ na izi ezi dị elu.
-
GDHL-100B Onye Nnwale Nguzogide Kọntaktị (Microhm Mita)
Ịrụ ọrụ nke sekit na-eduzi nke ihe nkedo sekit dị mkpa iji hụ na arụ ọrụ nchekwa nke mgba ọkụ.
-
GDGK-501 DC ike ọkọnọ
GDGK-501 na-enye ike na sekit breakers ma ọ bụ ndị ọzọ HV switches.
-
GDSL-BX-200 Ntụle ule ịgbanye isi ugbu a
GDSL-BX-200 Ihe Nnwale Nleba nke isi ugbu a, bụ nke a na-ejikarị na nhazi maka ihe ngbanwe dị ugbu a, ihe nchekwa moto, mgba ọkụ ikuku, kabinet mgba ọkụ, ihe mgbawa sekit, ihuenyo nchebe na wdg.
-
GDKC-15 Series Circuit Breaker Analyzer
Igwe ọkụ eletrik dị elu bụ otu n'ime ihe nchịkwa kachasị mkpa na usoro ike.
-
GDSL-D Seriese Digital Primary Nleba Nleba Nleba Ugbu a
GDSL-D usoro bụ isi ugbu a injection ule set, bụ ezigbo akụrụngwa iji nwalee elu-ugbu a ngwaọrụ na ike na eletriki ụlọ ọrụ, eji na ike osisi, nkesa ọdụ, eletriki n'ichepụta na nnyocha institutes, na atụmatụ nke obere size, ìhè arọ. , mfe iji na mmezi.
-
GDKC-12A (GDKC-12B) (GDKC-13A) sekit Breaker Analyzer
Igwe ọkụ eletrik dị elu bụ otu n'ime ihe nchịkwa kachasị mkpa na usoro ike.
-
GDSL-BX-100 Ntụle ule ịgbanye isi ugbu a
GDSL-BX-100 Ihe Nnwale Nleba nke isi ugbu a, bụ nke a na-ejikarị maka ịnwale ihe ngbanwe ugbu a, ihe nchekwa moto, mgba ọkụ ikuku, kabinet mgba ọkụ, ihe mgbawa sekit, ihuenyo nchebe na wdg.
-
GMDL-02A HV Circuit Breaker Analog Device
GMDL-02A na-arụ ngwaọrụ simulation sekit nke na-agbaji voltaji dị elu site na iji ụkpụrụ nke nnukwu ọnụ ụzọ ámá mmemme nwere ike ime, ngwaọrụ eletrọnịkị nwere nchedo, wdg.