Ọbụlagodi na ihe a na-akpọ usoro resonance “nwere ike niile”, ihe ndị a na-ejighị n'aka ka ga-emetụta nsonaazụ ule, gụnyere:
1. Mmetụta nke ihu igwe
N'ihe banyere oke iru mmiri, ọnwụ corona nke waya ndu na-abawanye nke ukwuu, na nnyonye anya nke oghere electromagnetic gbara ya gburugburu na-abawanye, nke na-eme ka uru Q na-ebelata.
2. Mmetụta nke oge ule
Site na ịgbatị oge ule ahụ, a na-ekpo ọkụ ngwa ngwa, nkwụsị nke nhata na-abawanye, uru Q na-egosikwa ọnọdụ ala.Ihe omume a na-apụta ìhè nke ọma na ihu igwe na-ekpo ọkụ, na mgbe mgbe, a na-achọ ka akụrụngwa zuru ike maka nkeji 30 tupu a nọgide na-eji ya.
GDTF usoro substation ugboro mgbanwe usoro resonance ngwaọrụ ule
3. Mmetụta nke reactor
Ọ bụrụ na etinyere reactor na akụkụ ọla dị ka efere ígwè, a ga-emepụta mfu nke ugbu a na nguzogide ya ga-abawanye.
4. Mmetụta nke ịghara ịhọrọ ebe resonance ka mma maka ugboro ugboro ule voltaji na uru Q.
N'ime ngwa ahụ, a na-achọpụta na mgbe voltaji na-ebili nso na volta ule, voltaji na-ebili ngwa ngwa ma na-esonyere ya na nnukwu mgbanwe voltaji, nke nwere ike ime ka nchebe voltaji rụọ ọrụ, nke mere na a ghaghị ịmaliteghachi ule ahụ, nke adịghị mma maka nchekwa nke akụrụngwa, ma Ọ bụrụ na ọnụ ahịa nchebe voltaji na-edozi oke, ọ gaghị enwe ike ichebe ngwá ọrụ dị n'okpuru ule site na oke ọkụ.Ya mere, a na-agbanwekarị ya ka ọ bụrụ ụda resonance ka mma na 2% nke voltaji ule, ma ọ bụrụ na ọ bụghị ihe karịrị 40% nke voltaji ule Ọ bụrụ na ọ dị mkpa, gbanwee ugboro ugboro ọzọ, mee ka ọ dị ntakịrị ntakịrị iji zere ihe dị n'elu.
5. Mmetụta nke elu voltaji na-eduga
Mgbe otu ihe nke ngwa eletriki na-edobe ule AC na-eguzogide voltaji, n'ihi obere ikike nke ngwaahịa ule, eriri elu voltaji na-enwe mmetụta dị nta na ule ahụ.Mgbe AC na-eguzogide ule voltaji nwere ike ime na ngwaọrụ nkesa ike n'èzí dum, ịdị elu nrụnye nke akụrụngwa na-abawanye na ọkwa voltaji.Ọkwa voltaji dị elu, ogologo waya ụzọ voltaji dị elu.N'ozuzu, eriri eriri voltaji dị elu na-adị ogologo, mfu corona na-eme ka ọ dịkwuo mma, na nkwụsi ike kwekọrọ na akaghị na-abawanye.A na-ejikọta ikike kpafuru akpafu nke a na-emepụta site na ya n'otu aka ahụ na ike a tụrụ atụ, na resonance ugboro nke loop na-ebelata, nke na-eme ka uru Q na-ebelata;n'otu oge ahụ, nnyonye anya nke mpaghara electromagnetic gbara ya gburugburu na-abawanye.Ọ na-eme ka uru Q daa.Ya mere, mgbe ị na-eme AC na-anagide voltaji ule nke elu-voltaji ngwa eletriki, gbalịa na-eji bellows elu voltaji lead.
Ya mere, na AC na-eguzogide voltaji ule, na mgbakwunye na ịdabere na ezi arụmọrụ nke usoro resonance, nlebara anya kwesịkwara ịkwụ ụgwọ voltaji equalization jikoro, dị ka: ezi uche nhọrọ nke wires, ezi uche okirikiri nhọrọ ukwuu nke saịtị ule, ezi uche nhazi oge. , wdg, na ikpo ọkụ na ikpo ọkụ nwekwara ike iwere.Usoro ahụ na-ebelata mmetụta na uru Q mgbe akụrụngwa na-ekpo ọkụ na mmiri.