Sistemụ ịchọta nsogbu eriri USB GD-4138H
GD-4138H Mobile Cable Fault Locating System bụ ihe dị mkpa iji dokwaa ụdị eriri niile.Ọ bụ akụrụngwa dakọtara nke nwere ike ịchọpụta, chọta eriri ndị dị n'okpuru ala, yana nha anya na-adịghị mma yana ọgbọ HV.Ebe ọ bụ ngwaọrụ mbugharị, ọ dị mma iburu na saịtị.Ọ bụrụ na ejikọ ihe nchọta ụda ọnụ, ọ nwere ike chọta ebe ziri ezi ebe ntụpọ eriri USB dị.
Ngwa bụ eriri n'okpuru ala, eriri ikuku, eriri ọkụ, eriri mpaghara, eriri nkwukọrịta na eriri eriri.
●Mmejọ nke na-ebufe elu impedance
●Mgbapụta impedance dị elu
●Ndabere na-eguzogide elu / dị ala
●Mmejọ mkpirisi okirikiri
●Mmejọ imeghe
●Njikọ/Mpụpụ adịghị mma
●GD-4138H isi etiti (ngwakọta njikọ, oghere oghere, generator HV dị n'ime)
●GD-4133 Multiple pulse cable fault tester
●GD-4132 Onye na-achọpụta ihe kpatara eriri USB
●Otutu uzo di iche iche: usoro usu obere voltaji, usoro usu ugbua, otutu uzo usu: nleba anya ugbua, mmepụta DC.
●Ụdị mgbaama nlele: Usoro ntụgharị DC arc, nlele ugbu a, nlele voltaji, usu voltaji dị ala.
●Chọta ngwa ngwa ma tụọ mmejọ ntapu na-eguzogide dị ala na mmejọ ọkụ ọkụ nke eriri ọkụ ọkwa 220V~220KV dị iche iche.
●Ọ dịghị mkpa imezuwiwi mgbagwoju anya maka nyocha saịtị.A na-agbanye ụdị ule niile na-akpaghị aka site na ngbanwe nke elu voltaji dị n'ime nke ugbu a adịghị ike na-achịkwa.
●Integrated multi-speed DC high-voltage generator, multi-speed high-voltage capacitor, arc stabilizing unit na dị iche iche mgbaama nweta n'ime otu, dị mfe iji rụọ ọrụ na-adịghị mma usoro.
●Multi-larịị mmepụta elu voltaji ịmafe, niile na-achịkwa nke esịtidem ala voltaji adịghị ike ugbu a, nchekwa na ntụkwasị obi.
●Ọdịdị nke akụrụngwa na-anabata ihe dị elu plastik.Ikpe ahụ bụ igbe dị n'èzí nke akụrụngwa na igbe mbufe maka ngwugwu nnyefe akụrụngwa.Ọ dị mma ịnyefe, enwere ike ibunye ya ma bufee ya ozugbo mgbe mkpuchi mkpuchi.
●Ọpụpụ oghere oghere oghere: oghere ikuku ikuku solenoid nke na-adịghị ike ugbu a, oge mwepu bụ mgbanwe site na 3 ruo 12 sekọnd, yana muffler bụ nke emebere nke ọma iji mezuo ihe achọrọ ogbi maka ọdịda USB na mbido.
●Akụrụngwa ahụ nwere sekit mgbapu arụrụ arụ.Mgbe emechara ule mmejọ ahụ, enwere ike gbanyụọ voltaji dị elu dị nnọọ pịa bọtịnụ na ọnọdụ nkwụsị ka ịpụpụ na-akpaghị aka.
●Onye na-ahụ maka nha anya nwere ike ịnye mkpebi nha anya dị anya ruo 0.4m, yana mpaghara kpuru ìsì dị ntakịrị, nke dị irè karịsịa maka mmejọ dị nso na obere eriri.
●A na-ahazi oghere mmepụta niile nke akụrụngwa n'azụ azụ maka wiwi dị mfe, a na-esekwa eserese nke usoro wiwi dị iche iche na panel ọrụ, nke ndị mmadụ na-enweghị ahụmahụ nwere ike iji ya mee ihe ngwa ngwa.
●A na-edozi ala nke akụrụngwa na wiil 4 na-agba ọsọ dị elu, nke nwere ike ịkwanye na ikpokọta maka nchekwa.
●Onye ọbịa na-agba ọsọ na-eji LCD ihuenyo buru ibu nke 7-inch nwere akụkụ nlele 160º, yana ọdịnaya ngosi bara ụba na nghọta.
●Enwere ike ịchekwa ọnụ ọgụgụ dị ukwuu nke ebili mmiri na onye ọbịa, na data waveform nwere ike ibubata na mbupụ site na iji diski U.
●Enwere ike ijikọ onye ọbịa na kọmpụta (desktọpụ ma ọ bụ akwụkwọ ndetu) maka nzikọrịta ozi ịntanetị.
●Mgbe onye ọbịa na-enweghị ọrụ n'ime nkeji 2, ọkụ azụ ga-ada mbà;ọ bụrụ na enweghị ọrụ maka nkeji 10, ọ ga-emechi ozugbo iji belata oriri ike;mgbe batrị na-erughị voltaji, ngwa a ga-emechikwa ozugbo iji chekwa batrị.
●Onye ọbịa ahụ nwere batrị lithium-ion polymer arụnyere ma kwado ya na chaja batrị lithium raara onwe ya nye iji nye usoro nchaji a pụrụ ịdabere na ya.
●The dum igwe adopts integral nyefe igbe Ọdịdị imewe, nke bụ kọmpat na ike, karịsịa adabara maka ewu saịtị ojiji.
| Nlereanya | GD-4138L | GD-4138M | GD-4138H |
| Ụdị ule | Usoro ntụgharị uche Arc, nlele ugbu a, mmepụta DC | Usoro ntụgharị uche Arc, usoro ntụgharị DC arc, nlele ugbu a, mmepụta DC | |
| Ụdị mgbama nlere anya | Usoro ntụgharị uche ọtụtụ pulse arc, nlele ugbu a, usu voltaji dị ala | Usoro ntụgharị uche Arc, usoro ntụgharị DC arc, nlele ugbu a, mmepụta DC | |
| Ihe mmepụta DC HV | 0~16KV adịghị mma polarity Ihe nrụpụta kacha ugbu a: 152mA | 0~32KV adịghị mma polarity Ihe nrụpụta kacha ugbu a: 76mA | 0~8KV polarity na-adịghị mma Ihe nrụpụta kacha ugbu a: 304mA 0~16KV polarity adịghị mma Ihe nrụpụta kacha ugbu a: 152mA 0~32KV polarity adịghị mma Ihe nrụpụta kacha ugbu a: 76mA |
| Flashover capacitance | 0-16kV 8μF Ike mmepụta kacha elu: 1024J | 0-32kV 4μF Ike mmepụta kacha elu: 2048J | 0-8kV 32μF Ike mmepụta kacha elu: 1024J 0-16kV 8μF Ike mmepụta kacha elu: 1024J 0-32kV 4μF Ike mmepụta kacha elu: 2048J |
| Mwepu oghere sphere na-akpaghị aka | Ọpụpụ ikuku valvụ solenoid na-adịghị ike ugbu a na-adịghị ike, oge ntọhapụ bụ mgbanwe site na 3 ruo 12 sekọnd, na muffler bụ nke emebere nke ọma iji zute ihe achọrọ ogbi maka ọdịda USB na mbido. | ||
| Ụdị mmepụta | DC na-eguzogide voltaji, otu mwepu, mwepu oge | ||
| DC iguzogide voltaji | 16KV | 32KV | 32KV |
| voltaji mkpali ntinye anabatara | 16kV | 32kV | 32kV |
| Ike ntinye ike anabatara | <2048J | ||
| Ebe ọrụ | Okpomọkụ: 0 ~ 40 ℃ Iru mmiri dị ala: <75% RH | ||
| Ịnye ọkụ | AC220V, 50Hz | ||
| Ngụkọta ikike | 3kVA | ||
A na-eji ya tụọ anya mperi.N'okpuru ọnọdụ pulse LV, enwere ike iji ya naanị ya.
7inch LCD ihuenyo, enyi na enyi interface.
Ụzọ ịchọta ọtụtụ anya:
Usoro pulse dị ala: ọ dị mma maka ịchọta nkwụsị nke nkwụsị nke dị ala, nkwụsị nke mkpụmkpụ, mmeghe oghere.Enwere ike iji ya na nha ogologo ogologo eriri, nkwonkwo etiti, nkwonkwo T, na nkwonkwo nkwụsị.Enwere ike iji usoro a dozie ọsọ nke ebili mmiri.
Usoro Pulse dị ugbu a: Ọ dabara maka nha anya nke mmejọ nguzogide dị elu, mmebi mmebi.Iji di na nwunye ugbu a na-anakọta akara site na waya ụwa, ọ na-eme ka onye ọrụ dị anya site na nnukwu voltaji.Usoro a dị mma na ntụkwasị obi.
Ọtụtụ pulse: ụzọ dị elu iji tụọ anya.Ụdị ebili mmiri dị mfe ịchọpụta na izi ezi dị elu.
Nlele 200MHz ozugbo.Oke.Mkpebi nha 0.4m.O nwere obere mpaghara nwụrụ anwụ ma bụrụ ihe pụrụ iche maka eriri obere na nso eriri eriri.
Metụ ihuenyo aka wee pịa ọrụ igodo.Enwere ike ịdọrọ cursor.
Mpempe akwụkwọ PIP (foto nchekwa nwa oge)
A ga-enwe windo bụ isi yana mpio nchekwa atọ nwa oge nwere ike ịlele ụdị ebili mmiri atọ ọnụ.
Sistemu eji arụ ọrụ arụnyere arụnyere
Njikwa ngwanrọ pụrụ iche maka nkwalite ngwanrọ, ndabere na iweghachi.
Ọrụ nha
Otu mmalite, kọntaktị 10, otu eriri USB na otu ogologo zuru ezu nwere ike ịtọ ntọala.
Gosipụta ọnụ ọgụgụ na nnwale ebili mmiri n'otu oge
Nchekwa Waveform na nkwukọrịta na kọmputa.
Nchekwa dị n'ime nke ụdị ebili mmiri.
Iji USB, budata ma ọ bụ bulite data
Mmekọrịta na kọmputa
Njikwa ike
Ìhè azụ na-ada mbà ma ọ bụrụ na ọ dịghị ọrụ na 2mins na gbanyụọ na 10mins ma ọ bụrụ na ọ dịghị ọrụ.
Batrị lithium-ion polymer arụnyere n'ime ya.
Oge ọrụ bụ ihe ruru awa 5 maka ojiji ọ bụla.
Ikpe siri ike, dị mfe iburu.
| Ụzọ ịchọta | Usoro mkpali obere voltaji Malite usoro ugbu a Ọtụtụ usoro mkpali |
| Oke.Ugboro nlele | 200MHz |
| Nweta oke | 0-70dB |
| Obere voltaji mkpali voltaji | 30V |
| Mkpebi kacha | 0.4m |
| Oke.Ịchọta nso | 100km |
| Mpaghara nwụrụ anwụ | 2m |
| Batrị | Nickel-metal hydride batrị enwere ike ịgbanye, oge ntachi obi karịrị awa 5 |
| Nkwurịta okwu interface | USB |
| Ịnye ọkụ | Ntinye AC220V, 50Hz, 2A dị ugbu a, na-akwụ ụgwọ maka awa 8 |
| Dim. | 274×218×81mm |
| Ibu | 3.5kg |
| Okpomọkụ na-arụ ọrụ | -10 ℃-40 ℃ |
| iru mmiri | 5-90%RH |
| Elu | <4500m |
●A na-enweta akara ngosi Acoustic na magnetik n'otu oge.Ike mgbochi nnyonye anya siri ike.
●Ngosipụta Waveform.
●Ngosipụta ihe ndọta acoustic.
●Ịchọta ebe ntụpọ na nchọ ụzọ.
●Jiri ekwe ntị ịnụ mkpọtụ.
●Ngosipụta ihuenyo LCD 320*240, enyi na enyi interface.
●Batrị Li arụnyere n'ime ya, nwere chaja ngwa ngwa.
●Ọ ga-agbanyụ na-akpaghị aka ma ọ bụrụ na ọ naghị arụ ọrụ mgbe nkeji iri na ise gachara ma ọ bụ obere batrị.
●Obere nha, dị mfe iburu.
●bandwit mgbama Acoustic: ugboro etiti 400Hz, bandwit 200Hz
●Nweta akara ngosi: 80db.
●Ebe ziri ezi: 0.1m
●Ọkụ ọkụ: batrị Li arụnyere, voltaji ọnụ 7.4V, 3000mAh, na-arụ ọrụ 9hours na-aga n'ihu.
●chaja: Ntinye AC220V±10%, 50Hz, mmepụta aha 8.4V, DC1A
●Oge nchaji: <4 awa
●Akụkụ: 270*150*210mm.
●Arọ: 1.5kg.
●Jiri ọnọdụ: okpomọkụ -10--40 ℃, iru mmiri 5-90% RH, elu <4500m.