GD-875/877 Igwefoto infrared thermal
●Nchịkwa akpaaka ma ọ bụ ntuziaka nke oke okpomọkụ nke agba agba
●℃, Celsius F na K nkeji nha
●11 onye ọrụ palette agba nwere ike họrọ
●9 asụsụ ndị nwere ike ịhọrọ
●Ntụnye ntụpọ okpomọkụ dị ọkụ
●Mmụta ntụpọ oyi oyi
● 4 nha ihe nwere ike ibugharị
● Ntọala mkpu okpomọkụ dị elu
●Reflected - Nkwụghachi ụgwọ okpomọkụ egosipụtara
●2x mbugharị dijitalụ
●Ihuenyo oyi kpọnwụrụ maka ịhụ onyonyo dị ugbu a
●Mpụta vidiyo - NTSC ma ọ bụ PAL
●Ntụle okpomọkụ na mpaghara 3
●2-ahịrị okpomọkụ nha
●Ndozi okpomọkụ ndabere
● TF kaadị nchekwa ihe oyiyi
●CMOS onyonyo ọkụ na nchekwa
● Ndekọ ọdịyo
●Isothermal mkpu
●Ndozi okpomoku, mgbazi ngbanwe nke nha
● Wuru na Emissivity ndepụta ndepụta ihe nkịtị
Ihe | Oke | |
Nchọpụta | Ụdị | Ụdị ikuku ikuku adịghị mma |
Pixel | 160*120 | |
Pixel pitch | 25μm | |
Ogologo ogologo ogologo | 8-14 mm | |
Ugboro nlele | 50Hz | |
Mmetụta okpomọkụ | 0.06℃@30 ℃ | |
oghere | Mpaghara nlele | 25°* 19° |
Ogologo ihe kacha nso | 10cm | |
Usoro mgbado anya | Ntinye akwụkwọ ntuziaka | |
oghere gbatịrị agbatị | 0.5x/2x, nhọrọ | |
Ụdị interface | Njikọ Baynet | |
Ọrụ onyonyo | Mkpebi oghere | 2.72 nkeji |
mbugharị eletrọnịkị | 2X | |
Igwefoto ọkụ na-ahụ anya | CMOS modul | |
Ọnụọgụ etiti | 50/60Hz, nhọrọ | |
Mmepụta vidiyo | PAL/NTSC, nhọrọ | |
Ngosipụta onyonyo | Ihuenyo LCD | 3.5 ″ TFT LCD,320*240,yi |
Agba palette | 11 agba palettes ịhọrọ site na | |
Ndozi onyonyo | Nchekwa onwe / akwụkwọ ntuziaka nke ọdịiche na nchapụta | |
Ngosipụta onyonyo | Gbanwee ngwa ngwa n'etiti infrared na onyonyo a na-ahụ anya | |
Nhazi onyonyo | akpaka / akwụkwọ ntuziaka | |
Ntụ | Oke okpomọkụ | -20℃~+350℃ |
Okpomọkụ ziri ezi | ±2℃or ±2% ọgụgụ, were nnukwu uru | |
Ndozi okpomọkụ | Akpaaka (obere oge, ogologo oge, oge omenala) / akwụkwọ ntuziaka | |
Ụkpụrụ nha | Ebe enwere ike ibugharị (ruo isi 4), ebe enwere ike ibugharị (ruo mpaghara 3, nha nkezi okpomọkụ, kacha / kacha nta nsochi okpomọkụ), ahịrị mbugharị (ruo ahịrị 2), ihuenyo zuru oke / kacha nta na nsochi okpomọkụ, ngosi ruo 5 Data otu;nyocha isothermal, nyocha ọdịiche okpomọkụ, nsochi okpomọkụ, mkpu okpomọkụ (ụda, agba) | |
Ndozi mgbazi | Enwere ike idozi site na 0.01 ruo 1.0 (n'ịkwalite 0.01) ma ọ bụ họrọ n'ime ndepụta ihe ndị eburu ụzọ kọwaa. | |
Ndozi okpomọkụ ndabere | akpaka | |
Ndozi nnyefe ikuku | Akpaaka, dabere n'ebe dị anya abanye, iru mmiri gburugburu na ọnọdụ okpomọkụ | |
Ọrụ nhazi | Ụbọchị/oge, nkeji okpomọkụ ℃/℉/ K, asụsụ | |
Nchekwa onyonyo | kaadị nchekwa | 8GB Micro TF kaadị, na-akwado ruo 16GB |
Ụdị nchekwa | Nchekwa akwụkwọ ntuziaka / akpaka;otu etiti onyonyo infrared, infrared na onyonyo metụtara ọkụ a na-ahụ anya | |
Ụdị onyonyo okpomọkụ | Ọkpụkpọ JPEG nwere data nha infrared raw | |
Ụdị onyonyo ọkụ a na-ahụ anya | Ụdị JPEG | |
Ederede olu | 60 sekọnd (jiri onyonyo chekwaa) | |
Ịnye ọkụ | Batrị | Batrị lithium enwere ike ibugharị, enwere ike dochie ya |
Oge ọrụ batrị | Na-aga n'ihu na-arụ ọrụ ihe karịrị awa 4 | |
Usoro nchaji | Nchaji smart chaja ma ọ bụ chaja na-enweghị usoro (ihe nkwụnye ọkụ AC ma ọ bụ ọkọnọ ike ụgbọ ala 12V) | |
Oge nchaji | Nchaji enweghị usoro maka awa 1.5 karịa ikike 50%. | |
Ụdị nchekwa ike | Nchekwa onwe akpaghị aka, nkwụsị akpaka | |
Interface | interface kaadị ebe nchekwa | Oghere Micro SD (TF kaadị). |
USB interface | Ee, nyefe data | |
Ngwa ngwa ọkọnọ ike | Ee (DC 12V) | |
Vidiyo mmepụta interface | Ee | |
Ndị ọzọ | Igwe okwu | Wuru n'ime |
Buzzer | Wuru n'ime | |
Laser positioner | Uhie, 1mw/635nm, klas 2, IEC60285 | |
Tripod eri | 1/4 ″-20-UNC | |
Ụgbọ okporo ígwè | Enwere ike itinye ya n'akụkụ abụọ | |
oghere oghere | Ee | |
Sunshade | Ee, nhọrọ | |
gburugburu | Ọnọdụ okpomọkụ na-arụ ọrụ | -15℃~+50℃ |
Ọnọdụ nchekwa | -40℃~+70℃ | |
iru mmiri | ≤95% na-abụghị condensing | |
Klas nchedo | IP54 | |
Nguzogide mmetụta | 25G, IEC68-2-29 | |
Mgbochi ịma jijiji | 2G, IEC68-2-6 | |
Daa | 2 mita | |
Anụ ahụ atụmatụ | Akụkụ | 105*230*245 mm |
Ibu | 980g |