GDSL-D Series Dijitalụ Nleba Nleba nke Isi Ugbu a
●DL/T 596-2005 "Usoro ule usoro maka ngwa eletriki"
●GB1094.1-GB1094.6-96 "Ọkwa nchedo shell"
●GB2900 "Okwu ọkụ eletrik"
●GB/T16927.1~2-1997 "High Voltage Test Technology"
●GB4793-1984 "Ihe nchekwa chọrọ maka ngwa nlegharị anya eletrọnịkị"
●GB191 "Ngwugwu Nchekwa na Akara Ụgbọ njem"
●GB / T.311-1997 "Mkpuchi na nchikota nke elu voltaji ike nnyefe na mgbanwe akụrụngwa"
●N'iji ọla kọpa dị elu conductivity dị ka electrode mmepụta, elu kọntaktị dị ukwuu na ikike ịgba ọsọ dị ike.
●Aluminom efere a na-akpụ akpụ na usoro ọhụrụ, dị mfe na nke na-adọrọ adọrọ, na-eguzogide ọgwụ na mmetọ.
●Igwe plastik na-agba agba niile na-ewu ewu na ụda kamel na-ewu ewu na mba ụwa siri ike ma bụrụ nke a pụrụ ịdabere na ya, na-eme ka a ghara ịdabere na ngwa ngwa.
●Ojiji breeki eluigwe na ala nkedo na-eme ka mmegharị ahụ na ndozi dịkwuo mfe ma dị mma.
●Ọwa ikuku ikuku nwere ụdị wedge iji kwalite mgbasa ọkụ yana ịgbatị ndụ ọrụ nke ukwuu.
●Igwe dum dị obere na nha dị arọ, nke dị mma maka iji ubi mee ihe.
●O nwere ọrụ nchebe efu iji gbochie mmetụta nke nnukwu ugbu a site na imebi ihe nlele ahụ.Enweghị ike ịmalite ya mgbe ọ nọghị na efu.
●Ọrụ nhọrọ mmetụta, mgbe a na-eme ule nkwụsị ngwa ngwa nke sekit, ọrụ nchebe efu nwere ike bepụ na uru achọrọ ugbu a nwere ike ịpụta ozugbo.
●Ụdị mmepụta ugbu a: ezi uru RMS na-agbanwe agbanwe mgbe niile.
●Nsonaazụ nke ugbu a bụ ebili mmiri sine ọkọlọtọ, yana ọnụego mgbagha nke waveform erughị 5%.
●Voltaji na ihe ngosi ugbu a na-anabataọhụrụ elu-nkenke LED dijitalụ ngosi
●Ogo nwere ike ịgbanwe agbanwe ugbu a iji kwalite ịdị mma ngosi maka ọgụgụ ziri ezi karịa.
●Enwere ike ịgbanye voltaji na-enye ọkụ na njikwa mmepụta voltaji ka ọ gosipụta maka ikiri dị mfe.
●Emebere ikike akụrụngwa maka obere oge, ọrụ na-adịte aka na nkeji 5.
●Maka ule batch, mechie nkeji iri ka nkeji 2.5 gachara ọrụ na-aga n'ihu.
●Ọ nwere ike tụọ oge ihe omume dị ugbu a nke akụrụngwa a nwalere wee dekọọ oge mkpọchi n'otu oge.(nhọrọ)
●Ogologo oge atụnyere: 0.001S~999.999S Mkpebi 1ms, njehie nha: 0.005% nso ± 2digs.(nhọrọ)
●Enwere ike igosipụta uru ule nke isi ugbu a na nke abụọ iji kwado ule mgbanwe mgbanwe.(nhọrọ)
●Nke abụọ dị ugbu a 0 ~ 5A mkpebi 1mA (nhọrọ)
●Ọ bụrụ na ịrị elu okpomọkụ (nkeji 30 - awa 24) kwesịrị ịhazi ya dabere na ịrị elu okpomọkụ ọrụ ogologo oge.(nhọrọ)
●Enwere ike ịhazi usoro atọ nke nwere nguzozi nguzozi riser (nhọrọ)
●Enwere ike ịhazi AC na DC riser (nhọrọ)
Nlereanya | Ike mmepụta(kVA) | Mpụta ugbu a(A) | Ịnye ọkụ(V) | Mepee voltaji sekit(V) | Power nkeji | Mark | |
GDSL-D-500 | 3 | 500 | 220 | 6 | LN | Integrated | |
GDSL-D-1000 | 6 | 1000 | 220 | 6 | LN | Integrated | |
GDSL-D-1500 | 9 | 1500 | 220 | 6 | LN | Integrated | |
GDSL-D-2000 | 12 | 2000 | 220 ma ọ bụ 380 | 6 | LN | AB | Integrated ma ọ bụ ngwakọta |
GDSL-D-2500 | 15 | 2500 | 220 ma ọ bụ 380 | 6 | LN | AB | Integrated ma ọ bụ ngwakọta |
GDSL-D-3000 | 18 | 3000 | 220 ma ọ bụ 380 | 6 | AB | Integrated ma ọ bụ ngwakọta | |
GDSL-D-4000 | 24 | 4000 | 380 | 6 | AB | ngwakọta | |
GDSL-D-5000 | 30 | 5000 | 380 | 6 | AB | ngwakọta | |
GDSL-D-6000 | 36 | 6000 | 380 | 6 | AB | ngwakọta | |
GDSL-D-8000 | 48 | 8000 | 380 | 6 | AB | ngwakọta | |
GDSL-D-10000 | 60 | 10000 | 380 | 6 | AB | ngwakọta | |
GDSL-D-12000 | 72 | 12000 | 380 | 6 | AB | ngwakọta | |
GDSL-D-15000 | 90 | 15000 | 380 | 6 | AB | ngwakọta | |
Enwere ike ịhazi ya n'ihi ihe ndị ahịa chọrọ |
Ntọala ule injection nke isi ugbu a | 1 ibe |
Ụdọ ọkụ | 1 ibe |
Waya ala ala | 1 ibe |
Ahịrị dị ugbu a dị elu (ọkọlọtọ 2m) | 2 ibe |
Asambodo | 1 oyiri |
Akwụkwọ ntuziaka | 1 oyiri |
Ndepụta nkwakọ ihe | 1 oyiri |
Akụkọ nnwale | 1 oyiri |