GDP-8000CM SF6 Ihe Nleba Ọkụ Iri Gas (Ụzọ mirror Chilled)
GDP-8000CM Portable Chilled Mirror SF6 Gas Dew Point Tester bụ nke emebere nke ọma maka nchọpụta mmiri ikuku gas SF6 nke ejiri na mpaghara okpomọkụ niile nke ụlọ ọrụ ike, nke dabere na Stryn refrigeration na ụkpụrụ nlele enyo oyi.
Ọ bụghị naanị na-edozi nsogbu ahụ na enweghị ike iji ụkpụrụ ikuku refrigeration nke Peltier n'ọhịa dị elu, ma dozie nsogbu ahụ na data nnwale nke mita mmiri na-eguzogide na capacitive enweghị ike kwụsie ike, ọsọ ule bụ. nwayọ, na data nha ezighi ezi.Enwere ike ịchọpụta ihe dị n'ime mmiri nke gas SF6 na okpomọkụ nke na-erughị 60ºC na gburugburu ebe obibi nke ziri ezi nke igirigi ± 0.2ºC.
Ngwaahịa a nwere ọsọ ule ngwa ngwa, arụmọrụ kwụsiri ike yana ezigbo nkwughachi.Ọ dabara maka nchọpụta micro mmiri nke SF6 gas ọhụrụ, gas na-emegharịghachi, gas na-agba ọsọ na gas na-adịghị mma na ụlọ ọrụ ike.
●Nyochaa mmiri nke akụrụngwa eletriki gas SF6 maka ọkụ eletrik.
●Nnwale ịdị mma gas SF6 gas cylinder
●Imepụta gas dị ọcha dị elu
●Semiconductor ụlọ ọrụ ọkọnọ gas kpọrọ nkụ
●Nyocha na mmepe ojiji
●Nleba anya ime ụlọ/akọrọ ụlọ dị ọcha
●Ebe ọgwụgwọ okpomọkụ metal na ụlọ nyocha ụlọ ọrụ mmepụta ihe na-achọpụta iru mmiri, dị ka ikuku, CO2, N2, H2, O2, SF6, He, Ar na gas inert ndị ọzọ.
●Mma karịa ±2℃ nha nha nha.
●Nhazi ihe eji eme ihe ọwa polymer niile, na-eme ka ọ nweghị ihe nledo mgbidi mmiri ma na-ekwe nkwa ọsọ nnwale.
●A na-eji ahụ na-achịkwa valvụ igwe anaghị agba nchara mmanụ na-enweghị mmanụ iji hụ na izi ezi nke uru tụrụ.
●Algọridim sọftụwia dị elu na-akwalite izi ezi nnwale nke sensọ.
●Ngwakọta nhazi nhazi chassis, ndị ọrụ nwere ike ijikọ ngwa na ngwa ndị metụtara ya ngwa ngwa.A na-ebu ngwugwu n'ozuzu ya, nke na-eme ka onye ọrụ nwee ahụ iru ala karị.
●Malite ule, ọ dịghị mkpa ka ikpo ọkụ naoscillate.
●Ntugharị okpomọkụ na mgbazi data nrụgide.
●Teknụzụ mgbakọ na-enweghị isi.
●Ike batrị lithium dị elu, ghọta AC na DC dual ike ọkọnọ.Enweghị ike AC na saịtị a chọrọ.Ọkụ batrị lithium na-aga n'ihu na-arụ ọrụ ihe karịrị awa 8 na-enweghị mkpa ọkụ ọkụ mpụga.
●Nhazi sekit nnyonye anya mgbochi elektrọnik iji hụ na ntụkwasị obi ngwaahịa.
●Ọ nwere ike gbasaa nkwurịta okwu USB, nkwurịta okwu serial, modul nkwurịta okwu ikuku, ma ghọta ọrụ nkwurịta okwu na mbipụta nke kọmputa dị elu.
●Ebe nchekwa dị ukwuu, nke nwere ike ịghọta 1000 nhazi ọrụ nchekwa data.
●Enwere ike iji ọrụ pretreatment ụzọ gas mee ka pipeline dị ọcha tupu ọrụ nyocha ubi, nke na-ebelata oge ule.(nhọrọ)
●Ngwa ahụ nwere ọrụ mgbake gas iji nwetaghachi gas nha sọlfọ hexafluoride.
●Data ule kwụsiri ike ma nwee ike ịnye ma ụkpụrụ akara igirigi atụgharịrị yana ụkpụrụ akara igirigi gbanwere na 20 ℃.
●Ebe nlele ule kacha mma na-egosi na onye ọrụ nwere ike ịhazigharị ikuku gas n'uche na ngwa ngwa.Belata oge ule.
●Emebere oghere ikuku nwere obere nkwonkwo na-ejide onwe ya, ụzọ ikuku a ga-anwale agaghị agbapụta mgbe a kwụsịrị ụzọ ikuku.
| Usoro nha | Ụzọ mirror oyi |
| Oke nha | ebe igirigi -110℃ --+20℃ (kwado ppmv) |
| izi ezi | ± 2 ℃ (mgbe ọnọdụ okpomọkụ dị n'okpuru 0 ℃, ihe mmetụta mmetụta bụ ebe ntu oyi) |
| Oge nzaghachi | 63% [90%] +20→-20℃ Td 5s[45s] -20→-60℃ Td 10s[240s] |
| Mkpebi | 0.01 ℃ |
| Nkwagharị ugboro ugboro | ± 2 ℃ |
| Ngalaba ngosi | ℃, ppm, ℃P20 (ụkpụrụ gbanwere na 20℃) |
| Gas eruba | 400-600ml / min |
| Ngosipụta ọsọ | 0-1000ml digital flowmeter |
| Ihe nlele gas mgbali | ≤1MPa |
| Ịnye ọkụ | 220VAC ± 10%, 50Hz, AC / DC ojiji, n'elu-ụgwọ nchebe, na-aga n'ihu na-arụ ọrụ bụ dịghị ala karịa 8hours. |
| Jiri okpomọkụ gburugburu | -20--+60 ℃ |
| iru mmiri gburugburu | 90% RH |
| Mmetụta uru nha | Enweghị mmetụta nke nrụgide na eruba |
| Akụkụ | 395*295*155mm |
| Ibu | ihe dịka 2kg |