HV-OWS-63 Sistemụ Nnwale Wave Oscillating (OWTS) maka nyocha PD dị na saịtị nke Cables
1. HV-OWS usoro bụ ihe integrated ele mmadụ anya n'ihu ule usoro, tumadi eji maka ele mmadụ anya n'ihu ihapu nchoputa nke ọkara voltaji cables.Usoro ule ugboro bụ 50Hz ka ọtụtụ narị Hz damping AC voltaji, damping AC voltaji eme site na usoro n'oge ule usoro nwere ike iru 60kV, na ọ na-ejikọta na elu usoro ngwaike na usoro software maka nchoputa.
● Teknụzụ semiconductor eletrik kachasị ọhụrụ
● Teknụzụ njikwa laser kachasị ọhụrụ
● Igwe ihe ngosi dijitalụ di elu na teknụzụ nzacha
● Teknụzụ njikwa netwọkụ ikuku dị elu.
2. Ngwa nha na nyocha nwere ike ịrụ nyocha data dịpụrụ adịpụ n'okpuru ọnọdụ netwọkụ.
3. Full English interface interface, ike ịdekọ oscillating voltaji waveforms na ele mmadụ anya n'ihu mgbaama waveforms, na-eme ozugbo ntụpọ n'oge pressurization usoro;
4. Na-egosipụta na-akpaghị aka ugboro, njupụta na nlele oge obosara nke oscillating voltaji waveform.
5. Ọ nwere ike nyochaa na-akpaghị aka na mgbasawanye waveform nke mgbanaka mgbapu akụkụ anwalela.
6. Na-egosipụta na akpaghị aka uru ule ọnwụ dielectric.
7. Na-akpaghị aka wepụta map ebe mwepu akụkụ ma wepụta akụkọ ndekọ aha, wee mepụta maapụ mgbakọ na mwepụ na-akpaghị aka.
voltaji mmepụta | Nke kachasị: ± 60kVelu |
Ogologo oge oscillation | 20Hz ~ 850Hz |
Inductance | 1.0H ~ 2.1H (nhọrọ) |
Nyocha data | Nyocha akwụkwọ ntuziaka, nyocha akpaka (analog na nzacha dijitalụ) |
A ga-atụle oke ike | 0.05-5uF |
Ịchaji voltaji dị ugbu a | 10mA |
Oke nnwale mwepu akụkụ | 10pC ~ 200nC |
nha nha nha nha | ± 0.1pC (nlele 14bits) |
Ọsọ ife efe | 50-300m / anyị |
Ịchọta izi ezi | ±0.1m |
Ịchọta mperi | ≤1% × ogologo eriri USB |
Nchọpụta ọkwa PD | Dị ka IEC60270 si kwuo |
PD chọta bandwidth | 100kHZ ~ 50MHZ akpaka ma ọ bụ nhọrọ ntuziaka |
Dielectric ọnwụ uru tan δ | 0.1% ~ 10% |
voltaji ọkọnọ | 180V ~ 250V, AC 50Hz |
Ọnọdụ okpomọkụ na-arụ ọrụ | -120 ℃ ~ + 60 ℃ |
Ibu | Ihe dịka 88kg |
Nha | Dayameta 650mm, elu 980mm |
Interface | WLAN (IEEE802.11g) / 100M Ethernet kaadị |
Mba. | Aha | Qty. |
1 | HV-OWS-63 oscillating ebili mmiri ule sistemu isi unit | 1 setịpụrụ |
2 | Kọmputa akwụkwọ ndetu (nke ejiri n'ime ule mwepu akụkụ nke ebili mmiri na sistemụ nyocha) | 1 setịpụrụ |
3 | Capacitor akwụ ụgwọ mpụga | 1 setịpụrụ |
4 | Elu voltaji pulse calibration generator | 1 setịpụrụ |
5 | Elu voltaji ule USB | 1 setịpụrụ |
6 | Igwe na-ejikọ oke voltaji (njikọ capacitors akwụ ụgwọ) | 1 setịpụrụ |
7 | Igwe na-eme ka ọkpụ akpụ ọkụ ọkụ (otu uhie na otu ojii) | 2pcs |
8 | USB nnweta njikwa | 1pc |
9 | Igwe nkwurịta okwu netwọkụ (ya na ọdụ ụgbọ mmiri ruo ụdị-c modul) | 1pc |
10 | waya ala | 1pc |
11 | mkpanaka ala | 1pc |
12 | Igwe ọkụ | 1pc |
13 | Ngwa waya ngwugwu | 1pc |
14 | Akwụkwọ ntuziaka ọrụ | 1 oyiri |
15 | Akwụkwọ ikike / akwụkwọ ikike | 1 oyiri |
16 | Ndepụta nkwakọ ihe | 1 oyiri |