GDCR-3200C Mgbochi Ugboro Abụọ Multifunctional Ụwa Resistance Tester
GDCR3200C Double Clamp Multifunctional Earth Resistance Tester bụ nke ahaziri ma rụpụta ya maka nha na saịtị nke nguzogide grounding, resistivity ala, voltaji grounding, grounding line leakage current, AC current and DC resistance.Ngwá ọrụ ahụ na-eji teknụzụ nhazi dijitalụ dị elu, yana usoro 2-waya, usoro 3-waya, usoro 4-waya, usoro nhọrọ, ụzọ mwekota okpukpu abụọ na ụzọ nha ndị ọzọ;Mbubata FFT (Fast Fourier Transform) teknụzụ, AFC (Automatic Frequency Control) teknụzụ, nwere ikike mgbochi pụrụ iche na mgbanwe gburugburu ebe obibi, nnwale nnwale ugboro ugboro, na-eme ka njiri dị elu, nkwụsi ike dị elu na ntụkwasị obi dị elu maka nha ogologo oge. Ngwa eji eme ihe. nnukwu caliber ugbu a mwekota imewe, nwere ike na-emeso ụdị ọ bụla nke ule chọrọ, nwere ike ịlele grounding uru uru nke nnukwu size ala ala ụzọ, mgbanwe na-atụle grounding nguzogide uru nke otu ebe na grid grounding na ụdị nile nke mgbagwoju grounding Ọdịdị, ọ dịghị mkpa ịkwụpụ njikọ ọ bụla yiri njikọ ụwa mgbe ị na-atụle usoro nhazi ala, na-eme ka ịdị mma nke nha dịkwuo mma, n'ihi na ule arụmọrụ grounding na-enye ngwọta zuru oke.
GDCR3200C Double Clamp Multifunctional Earth Resistance Tester bụ igwe nnabata, mgbachi dị ugbu a (mkpọchi okpukpu abụọ), wires ule, mkpanaka ala inyeaka, ngwanrọ data na wires nkwukọrịta na ihe ndị ọzọ.Ngosipụta LCD buru ibu nke igwe nnabata nwere ọkụ azụ na-acha ọcha na ihe ngosi ihe ngosi mmanya nwere ike ịhụ nke ọma.Onye nleba anya nwere ọrụ nchekwa, ọrụ elekere, ma na-echekwa 2000 otu nsonaazụ ule na-akpaghị aka nwere ụbọchị na oge. Onye nyocha nwere ọrụ nkwukọrịta Bluetooth na-akwado sistemụ gam akporo.Mgbe echichi nke APP, nwere ike nwalee ma ọ bụ gụọ ule ndekọ na mobile ọnụ, na-eweta ọhụrụ ahụmahụ.Ihe nnwale ahụ na-akwado interface USB, enwere ike ibugo data echekwara na PC site na interface USB.Akụrụngwa nkwurịta okwu nwere ike ghọta ọrụ nke ịgụ akwụkwọ, nyocha, ịchekwa, ịkọ akụkọ na ibipụta data ndekọ akụkọ ihe mere eme.A na-ejikarị ike, nkwukọrịta, meteorology, ubi mmanụ, ihe owuwu, nchebe ọkụ na ngwá ọrụ eletrik ụlọ ọrụ.
●Nhazi pụrụ iche nke ọkụ egosi jack, ihe ngosi ziri ezi nke ọnọdụ jakị, zere njehie ọrụ.
●Gọọmenti na-arụ ọrụ igodo nhọrọ, a na-egosipụta ụzọ nnwale dị iche iche, na-eme ka ọrụ ahụ dị mfe na ngwa ngwa.
●Ihe nnwale ahụ nwere ọrụ nkwukọrịta Bluetooth ma na-akwado sistemụ gam akporo.Ndị ọrụ nwere ike iji ọnụ ekwentị iji nwalee ọrụ ma ọ bụ gụọ nsonaazụ ule nwere ụbọchị na oge nke ọma.
●Igwe ihe eji eme ihe na-anabata igbe nchebe mmiri, nke siri ike, dị mma ma dịgidere maka mgbochi, mgbochi ọdịda na mgbochi mmiri (ọkwa nchekwa IP65), karịsịa kwesịrị ekwesị maka iji mee ihe na ebe a na-ewu ụlọ.
●Ejiri mita ahụ nwere nnukwu mkpọ batrị lithium nwere ike ịchaji.Na iji eriri USB bulite ọrụ data.
Ọnọdụ ndị bụ isi & Ọnọdụ ọrụ
Mmetụta Ọnụ ọgụgụ | Ọnọdụ ntọala | Ọnọdụ ọrụ | kwuo |
Ọnọdụ okpomọkụ | 23 ℃ ± 1 ℃ | -10 ℃-40 ℃ | ---- |
iru mmiri gburugburu | 40%-60% | .80% | ---- |
Voltaji na-arụ ọrụ | 7.8V±0.1V | DC 7.8V±0.6V | ---- |
Nguzogide ụwa inyeaka | .100Ω | .5kΩ | |
Voltaji nnyonye anya | Kwesịrị izere | .20V | |
Ntinye aka ugbu a | Kwesịrị izere | .2A | |
Ogologo Electrode mgbe ị na-atụ R | a>5d | a>5d | |
Ogologo Electrode mgbe ị na-atụ ρ | a>20h | a>20h |
Nkọwapụta izugbe
Ọrụ | tụọ nguzogide grounding, ala resistivity;DC-eguzogide, voltaji ụwa, ọzọ ugbu a, ntapu ugbu a | |
Ịnye ọkụ | DC 7.4V 2600mAh batrị lithium nwere ike ịgbanye, juputara ihe dịka 8.4V | |
Ìhè azụ | Ìhè azụ ihuenyo nwere ike ịchịkwa, dabara adaba maka ebe ndị dara ada | |
Usoro nha | DC iguzogide | DC eguzogide 2-waya usoro |
DC-eguzogide 4-waya usoro | ||
Nguzogide ụwa | Usoro nguzogide ụwa 2-waya | |
Usoro mgbanaka ụwa 3-waya | ||
Usoro mgbanaka ụwa 4-waya | ||
Uwa na-eguzogide otu mwekota 3-waya usoro (usoro nhọrọ) | ||
Uwa na-eguzogide otu mwekota 4-waya usoro (usoro nhọrọ) | ||
Ụwa mgbochi double mwekota usoro | ||
Iguzogide ala (usoro Wenner) | ||
Ụwa ugbu a | Ntụ njide dị ugbu a | |
Voltaji ụwa | Nkezi mmezi | |
Nwalee Wave voltaji | Sine ife | |
Ugboro ule | 128Hz/111Hz/105Hz/94Hz(AFC) | |
Nnwale obere okirikiri dị ugbu a | AC 250mA max | |
Nnwale mepere emepe ugbu a | AC 40V max | |
Ogologo Ogologo Electrode | 1m-100m | |
Ụdị ngosi | 4-dijitalụ nnukwu LCD ngosi, na ihuenyo backlight | |
Ngosipụta nha | N'oge nha, LED flash egosi, LCD agụta ngosi | |
Akụkụ LCD Frame | 128mm × 75mm | |
Mpaghara ngosi LCD | 124mm × 67mm | |
Akụkụ akụrụngwa | 280mm(L) X 260mm(W) X 160mm(H) | |
Nha CT | 223mm x 120mm x 39mm | |
Nwale waya | 4 wires: nke ọ bụla maka uhie 20m, nwa 20m, odo 10m, na akwụkwọ ndụ akwụkwọ ndụ 10m | |
Mfe ule waya | 2 wires: nke ọ bụla maka uhie 1.6m na ojii 1.6m | |
Mkpanaka Grounding Enyemaka | 4PCS: Φ10mm X150mm | |
Mkpọchi dị ugbu a | 2PCS: 1 plọg na-acha anụnụ anụnụ na 1 plọg na-acha uhie uhie | |
Ihe mgbochi Caliber | Φ70mm | |
Mwekota Lead Waya | 2m | |
Ọnụego atụ | AC ugbu a: ihe dị ka ugboro 2/sekọnd | |
Voltaji Ụwa: ihe dị ka ugboro abụọ n'otu nkeji | ||
Nguzogide ụwa: ihe dịka 7 sekọnd / oge | ||
Ogologo oge | Ihe karịrị ugboro 5000 (Nnwale obere okirikiri, oge etiti kwesịrị ịbụ opekata mpe 30 sekọnd) | |
Voltaji Line | Ntụle n'okpuru AC 600V | |
Interface nkwurịta okwu | Enwere ike ibugo modul Bluetooth, interface USB, data nchekwa na kọmpụta, chekwaa ma ọ bụ bipụta ya. | |
Waya nkwukọrịta | USB nkwurịta okwu waya x1pcs, na ogologo 1.5m | |
Jide data | Ọrụ njide data: ngosi akara "HOLD". | |
Nchekwa data | 2000 otu, “MEM” nchekwa egosi, “FULL” akara ngosi flash nchekwa ezuola | |
Nweta data | Ọrụ ọgụgụ data: "READ" ngosi akara | |
Ngosipụta njupụta | Gafere ọrụ oke oke nha: "OL" ngosi | |
Ihe ngosi dị ala dị ugbu a nke njigide dị ugbu a | Ntụle na usoro nhọrọ ma ọ bụ mwekota okpukpu abụọ, akara ngosi ugbu a nke CT2 nwetara dị ala karịa 0.5mA, ga-egosipụta "", ma kwesịrị ịlele ntụziaka njigide nke CT2 ugbu a mwekota. | |
Nnwale nnyonye anya | Nchọpụta akpaaka nke akara ndabichi, akara “NOISE” na-egosi mgbe voltaji nnyonye anya dị elu karịa 5V | |
Nnwale mgbanaka inyeaka | Na inyeaka grounding nguzogide ule ọrụ, 0.00KΩ-30kΩ(100R+rC <50kΩ, 100R+rP <50kΩ) | |
Ọrụ mkpu | Ntụle uru gafere uru ntọala mkpu, ga-ewepụta ụda mkpu "Toot-toot-toot". | |
Voltaji batrị | Ọ bụ ezie na voltaji batrị na-agbada na gburugburu 7.2V± 0.1V, ga-egosipụta akara ngosi batrị dị ala, na-echetara iji dochie batrị ahụ. | |
Mkpuchi akpaaka | Gbanyụọ na akpaghị aka ka agbanyere nkeji iri na ise | |
Na-arụ ọrụ ugbu a | Ìhè azụ: 25mA Max (naanị ike ọkụ azụ) | |
Njikere:25mA Max (ọkụ azụ gbanyụrụ ọkụ) | ||
Atụ: 150mA Max (Agbanyụ ọkụ azụ) | ||
Ibu | Onye nyocha: 2290g | |
Mkpọchi ugbu a: 1100g (2pcs) | ||
Mkpokọta arọ: 6800g (gụnyere ngwa niile) | ||
Okpomọkụ na-arụ ọrụ & iru mmiri | -10 ℃-40 ℃, n'okpuru 80% rh | |
Ọnọdụ nchekwa & iru mmiri | -20 ℃-60 ℃, n'okpuru 70% rh | |
Ọkwa nchekwa | IP65 (mechie igbe ahụ) | |
Nchekwa oke ibu | tụọ nguzogide ụwa: n'etiti oghere ọ bụla nke C (H) -E,P(S)-ES, AC 280V/3 sekọnd | |
Nguzogide mkpuchi | Ihe karịrị 20MΩ (n'etiti sekit na mpụga shei bụ 500V) | |
Ịnagide Voltaji | AC 3700V / ms.(N'etiti sekit na mpụga shei) | |
Atụmatụ eletrọnịkị | IEC 61326 (EMC) | |
Ụdị Nchedo | IEC61010-1 (CAT Ⅲ 300V,CAT IV 150V,Mmetọ 2); IEC61010-031; IEC61557-1 (Ụwa na-eguzogide); IEC61557-5 (Igbo ala ala); JJG 366-2004 (mita nguzogide ala) JJG 1054-2009 (mita nguzogide ala) |