GDPDS-341 SF6 Eletriki Mkpuchi State Comprehensive Analyzer
Ka ọ dị ugbu a, ọkwa voltaji UHV nke 110KV na n'elu na-eji SF6 gas mkpuchi mkpuchi mkpuchi GIS dị ka akụrụngwa bụ isi nke ọdụ ụgbọ mmiri ahụ, a na-enweta nyocha nke ọnọdụ mkpuchi n'ime GIS site na usoro nchọpụta akụkụ akụkụ na usoro nyocha kemịkalụ gas SF6 n'ụlọ. na mba ofesi.Mgbe mwepu akụkụ na-apụta na mmalite nke mmebi mkpuchi n'ime GIS, ọ ga-ebute nnukwu ihe egwu nchekwa na ọrụ nchekwa ya.Ụzọ nchọpụta nke mwepu akụkụ akụkụ na-agụnye ụzọ atọ: ule mwepu akụkụ ultra-high, ultrasonic partial mm test, and chemical detection of gas SF6.Ka ọ dị ugbu a, enwere ngwaọrụ dị iche iche maka ụdị ụzọ nnwale ndị a na ahịa.Maka nchọpụta ndụ nke GIS na saịtị, a chọrọ ndị ọkachamara ọkachamara abụọ na eletriki na kemịkalụ ka ha buru ọtụtụ ngwa n'otu oge iji mepụta mwepu akụkụ na nchọpụta gas SF6, ma mgbanwe na oge adịghị mma.N'ihi ọnọdụ dị ugbu a nke nchọpụta mwepu akụkụ na GIS, ụlọ ọrụ HV HIPOT webatara teknụzụ dị elu nke mba ụwa iji mepụta ihe nyocha ihe mkpuchi ọkụ eletrik SF6.Nchikota nke usoro UHF, usoro ultrasonic na SF6 gas analysis n'ime otu ngwá ọrụ nwere ike imeziwanye nchọpụta nchọpụta na usoro ikpe nke nkwụsịtụ nkwụsịtụ na ngwá ọrụ GIS, ma melite izi ezi nke ikpe nkwụsịtụ, nye nkwado teknụzụ a pụrụ ịdabere na ya maka mkpebi mmezi.
Na mgbakwunye na akụkụ nyocha gas SF6, SF6 eletriki mkpuchi steeti zuru oke na-ejikọta teknụzụ nchọpụta mwepu akụkụ.Ndị na-arụ ọrụ nwere ike iji ngwa nchọpụta mwepu akụkụ iji mee nnwale na nlele mbụ na ngwa eletrik nwalere.Ozugbo achọpụtara na akụrụngwa eletrik na-enyo enyo na ọ ga-emebi mkpuchi mkpuchi akụkụ, akụkụ nyocha gas SF6 nwere ike iji ozugbo mee nyocha gas SF6, nyocha anụ ahụ na kemịkal.Enwere ike ikpebi ọnọdụ mkpuchi nke ihe a nwalere site na ịjụ ajụjụ ụkpụrụ mba kwekọrọ na nsonaazụ anụ ahụ na nke kemịkal.N'otu oge ahụ, enwere ike ịme nyocha gas SF6 na nnwale mwepu akụkụ n'otu oge.Site n'ịkọwa data nke ọnụọgụ anụ ahụ na ọnụọgụ kemịkalụ, anyị nwere ike kpee ikpe n'ụzọ ziri ezi na ọnọdụ mkpuchi na mmejọ nke akụrụngwa eletrik.
Isi uru nke SF6 eletriki mkpuchi mkpuchi ọnọdụ zuru ezu analyzer bụ na ọ nwere ike ikpebi n'ụzọ zuru ezu ọnọdụ mkpuchi nke ngwa eletriki site na nsonaazụ abụọ nke mwepu akụkụ na SF6 gas nyocha anụ ahụ na kemịkal, ma nwee ike ikpebi ọnọdụ ọrụ nke ngwa eletriki ngwa ngwa na nke ọma.Enwere ike iji ya dị ka ngwa nnwale zuru oke maka nyocha saịtị nke SF6 gas micro-water, ịdị ọcha na ngwaahịa ire ere.
●Mwepu akụkụ na nyocha nke mmiri mmiri, ịdị ọcha na ngwaahịa ire ere nke ngwa eletriki gas SF6 maka ọkụ eletrik.
●Nnwale ịdị mma gas SF6 gas cylinder.
●Nnwale dị mma nke gas SF6 maka mgbake na ijikwa ya.
●Imepụta gas dị ọcha dị elu.
●Semiconductor ụlọ ọrụ ọkọnọ gas kpọrọ nkụ.
●Nyocha na mmepe ojiji.
●Nleba anya ime ụlọ/akọrọ ụlọ dị ọcha.
●Ebe ọgwụgwọ okpomọkụ metal na ụlọ nyocha ụlọ ọrụ mmepụta ihe na-achọpụta iru mmiri, dị ka ikuku, CO2, N2, H2, O2, SF6, He, Ar na gas inert ndị ọzọ.
●Akụrụngwa nyocha mwepụ akụkụ nke dabere na sistemụ agbakwunyere ARM, sọftụwia ngosi dabere na sistemụ windo.
●Usoro ngwanrọ na-ekpe ikpe ike na ọnọdụ dị ka data nchọpụta siri dị, ma nwee ike igosipụta maapụ PRPS na PRPD, eserese ellipse, maapụ ọnụego mwepu, maapụ QT, maapụ NT, maapụ PRPD mkpokọta, maapụ ϕ-QN nke ọwa mgbaàmà ọ bụla, ma nwee ike igosipụta njupụta mgbaàmà PD na ọnụọgụ ọwa nke ọwa ọ bụla.Enwere ike ịchekwa data niile ozugbo.
●Onye nnabata data nwere ike hazie ọwa 4 n'otu oge nke otu sensọ ma ọ bụ dị iche, ma nwee ike ịnakọta ma nyochaa ọwa 4 nke akara n'otu oge.
●bọọdụ nlele ọsọ ọsọ dị elu nke wulitere onwe ya, nweta data synchronous chanel 4, nhazi akara ngosi, mmịpụta oke njirimara, enwere ike iziga data na ọdụ ekwentị site na waya na ikuku.
●Ihe mmetụta dị elu niile ebubata nwere ọrụ mmezi onwe ya na-ahụ na data nchọpụta nke mmiri, ịdị ọcha na ngwaahịa ire ere kwụsiri ike na ntụkwasị obi n'ime afọ.
●Ụzọ gas niile nwere imewe ihe eji eme ihe polymer dị elu, na-eme ka ọ nweghị ihe nledo mgbidi mmiri ma na-ekwe nkwa ọsọ nnwale.
●A na-eji ahụ na-ahazi valvụ igwe anaghị agba nchara mmanụ iji hụ na uru a tụrụ atụruru.
●Algọridim sọftụwia dị elu na-akwalite izi ezi nnwale nke sensọ.
●Enwere ike ịchọta mmalite, na-enweghị usoro oscillation, mgbanwe okpomọkụ na mgbazi data nrụgide.
●Ike batrị lithium dị elu, ghọta AC na DC dual ike ọkọnọ.Enweghị ike AC na saịtị a chọrọ.Ọkụ batrị lithium na-aga n'ihu na-arụ ọrụ ihe karịrị awa 8 na-enweghị mkpa ọkụ ọkụ mpụga.
●Nhazi sekit nnyonye anya mgbochi elektrọnik iji hụ na ntụkwasị obi ngwaahịa.
●Enwere ike ịnye data nyocha kwụsiri ike, uru akara igirigi ọkọlọtọ na uru akara igirigi gbanwere na 20 ℃ n'otu oge.
●Izizi nha ịdị ọcha bụ 0.5% nke oke zuru oke, nke enwere ike itinye ya na nha nke ikuku SF6 dị elu yana ọdịnaya 70% SF6 gas.
●Ngosipụta ebe nyocha kachasị mma, onye ọrụ nwere ike ịhazigharị ikuku gas ngwa ngwa, belata oge ule.
●Emebere ntinye ya na nkwonkwo micro self sealing, yabụ ụzọ gas a tụrụ atụ agaghị awụpụ mgbe a kwụsịrị ụzọ gas ahụ.
●Swagelok igwe anaghị agba nchara nchara ule pipeline na-eji na ule gas circuit, nke na-agbatị ndụ ọrụ nke akụrụngwa.
Akụkụ nchọpụta mwepu akụkụ:
Onye nnabata akara ngosi PD | |
Ugboro CPU arụ ọrụ | 1.2GHz |
Sistemụ nrụọrụ | Sistemụ arụ ọrụ agbakwunyere Linx |
Ọdụ ụgbọ mmiri netwọk ikuku | ọdụ ụgbọ mmiri LAN |
Ọdụ ụgbọ mmiri ikuku ikuku | WiFi ikuku arụnyere n'ime ya |
Ebe nchekwa sistemụ na-agba ọsọ | 512M |
Ebe nchekwa sistemụ | 256M |
Ugboro nnweta data | 250MHz |
Ọwa nchọpụta Ultrasonic | |
Oke nha | AE: 0-10mV; AA: 0-100dBuV |
Oke nchọpụta ugboro ugboro | 20 ~ 200kHz |
Ọwa nchọpụta UHF | |
Ugboro nchọpụta | 300 ~ 1800MHz |
Oke nha | -80-0dBm |
Njehie | ±1dBm |
Mkpebi | 1dBm |
Ọwa nchọpụta HFCT | |
Oke ugboro | 0.5 ~ 100MHz |
Njehie | ±1dB |
Mmetụta | 15mV/1mA |
Oke dị ike | 60dB |
Oke nha | 0-1000mV |
izi ezi | 1dB |
Ọwa nchọpụta TEV | |
Oke ugboro | 3 ~ 100MHz |
Oke nha | 0-60dBmV |
Mmetụta | 0.01mV |
Njehie | ± 1dBmV |
Mkpebi | 1dBmV |
Batrị | |
Batrị arụnyere n'ime ya | batrị lithium, 12V,6000mAh |
Jiri oge mee ihe | gbasara10awa |
Oge nchaji | Ihe gbasara4awa |
Nchekwa batrị | N'elu voltaji na n'elu-ugbu a nchebe |
Nchaji batrịer | |
Egosiri voltaji | 12.6V |
Nchaji mmepụta ugbu a | 2A |
Ọnọdụ okpomọkụ na-arụ ọrụ | -20 ℃-60 ℃ |
iru mmiri na-arụ ọrụ | <80% |
Ngosipụta data na ọnụ nyocha | |
Akụrụngwa dabara adaba maka onye nnabata ọ bụla nwere sistemụ Windows, ndị ọrụ nwere ike họrọ ya n'onwe ha. | |
Ebe ọrụ | |
Ọnọdụ okpomọkụ na-arụ ọrụ | -20 ℃ ~ 50 ℃ |
iru mmiri gburugburu | 0 ~ 90% RH |
Ọkwa IP | 54 |
SF6 gas nyocha akụkụ
SF6 iru mmiri
●Usoro nha: ụkpụrụ nguzogide na ike
●Oke nha: ebe igirigi -80℃--+20℃ (kwado ppmv)
●Nke ziri ezi: ± 1 ℃
(mgbe okpomọkụ ebe igirigi dị n'okpuru 0 ℃, ihe mmetụta mmetụta bụ ebe ntu oyi)
●Oge nzaghachi: 63% [90%]
+20→-20℃ Td 5s[45s]
-20→-60℃ Td 10s[240s]
●Mkpebi: 0.01 ℃
●Mmegharị: ± 0.5 ℃
●Ngosipụta unit: ℃, ppm, ℃P20 (ụkpụrụ gbanwere na 20℃)
SF6 ịdị ọcha
●Usoro nha: Ụkpụrụ nha infrared (usoro sensọ NDIR)
●Oke nha: 0 ~ 100% SF6
●Oge nzaghachi: [90%] 60s
●Nzizi: ± 0.5%FS
●Nkwaghari: ± 0.5%
●Mkpebi: 0.01%
●Ngalaba ngosi:%
Ngwaahịa ire ere SF6
●Usoro nledo: Ụkpụrụ nha nke Electrochemical (Electrochemical series sensọ)
●Oke nha: H2S: 0 ~ 100ppmv
SO2: 0 ~ 100ppmv
CO: 0 ~ 500ppmv
HF: 0 ~ 50ppmv
●Mkpebi: 0.5ppmv
●Ngalaba ngosi: ppmv
Usoro ikuku
●Ntụle igirigi: SF6 na gas ndị ọzọ: 400-600ml / min
SF6 nha ịdị ọcha: 300-450ml / min
Ngwaahịa ire ere SF6: 250-300ml / min
●Ngosipụta ọsọ: 0-1000ml dijitalụ eruba mita
●Ihe nlele gas mgbali: ≤1MPa
●Nchekwa ihe mmetụta: igwe anaghị agba nchara sintered filter
●Ike ọkọnọ: 110-220VAC ± 10%, 50Hz, AC / DC ojiji, n'elu-ụgwọ nchebe, na-aga n'ihu na-arụ ọrụ bụ ọ dịghị ala karịa 8hours.
●Jiri okpomọkụ gburugburu: -20--+60 ℃
●Mpaghara ọrụ: okpomọkụ: -35 - 70 ℃
Nrụgide: 0-20bar
Ihe nlele gas eruba ọnụego: enweghị mmetụta
●iru mmiri: 90% RH
●Akụkụ: 570*418*320mm
●Arọ: ihe dịka 18kg.
Onye nyocha isi | 1 ibe |
Ihe mmetụta UHF | 1 ibe |
Ihe mmetụta ultrasonic | 1 ibe |
Ihe mmetụta TEV | 1 ibe |
HFCT | 1 ibe |
eriri njikọ mgbaàmà | 1 ibe |
Njikọ | 1 set |
Teflon ọkpọkọ (gụnyere valvụ na-emezigharị mmiri na njikọ ngwa ngwa) | 1 set |
Ọdụdọ ọdụ | 1 set |
Akụkụ mapụtara | 1 set |
chaja | 1 ibe |
Ntuziaka onye ọrụ | 1 ibe |
Akụkọ nnwale | 1 ibe |